Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Automated Unit Testing is unavailable

Valid from Pega Version 7.1.1

Automated Unit Testing (AUT) is unavailable in 7.1.1 - 7.1.5.

Starting in 7.1.6, users can access AUT features from supported browser versions of IE.

IE8 limits expansion features

Valid from Pega Version 7.1.1

Internet Explorer 8 (IE8) does not support CSS media queries, which are used by re-expansion features in the Designer Studio. IE8 users with low screen resolution (800 x 600) and a small window size may find that the explorer area in the Designer Studio collapses but cannot re-expand. 

As a work around, access the Designer Studio from another supported browser version and use the recommended, minimum screen resolution width of 1280 pixels.

Limited access for end user portals

Valid from Pega Version 7.1.1

The following portals are only accessible from supported versions of Internet Explorer in “quirks” mode:

  • WorkUser
  • WorkManager

Nesting dynamic containers not supported

Valid from Pega Version 7.1.1

Do not include a section containing a dynamic container inside of another dynamic container. This configuration may cause performance issues resulting in unexpected behavior at runtime, and is not supported.

ShowWarningOnForm is no longer processed

Valid from Pega Version 7.1.7

Rule forms now display all warnings, independent of category or type. The standard decision tree Embed-Warning.ShowWarningOnForm is no longer used to determine which warnings are visible.

You can safely remove any specialized versions of this rule in your application.

List view and summary view reports might not display in HTML5-compliant browsers

Valid from Pega Version 7.1.7

List view and summary view reports use framesets to provide a view of drill-down reports. HTML5 does not support framesets, so these reports might not display well, or at all, in versions of browsers that are compliant with HTML5.

To prevent display issues, re-create the custom list view and summary view reports that you need as report definition reports. Standard management reports are already available as report definition reports.

As of Pega 7.2, list view and summary view rules are deprecated. For more information, see Discontinued support for list view and summary view rules.

Noticeable differences between work objects created in the Decision Manager portal when compared to Designer Studio

Valid from Pega Version 7.1.7

In the Decision Manager portal, you create work objects by running flows in the enterprise application that serves as the base application for the application overlay. If the enterprise application does not include the UI-Kit-7 in its application rulesets, work objects can display differently in the Decision Manager portal when compared to Designer Studio because an application overlay is always configured to include the UI-Kit-7 ruleset.

Recommendation:

  1. Add the UI-Kit-7 ruleset dependency to the enterprise application.
  2. Redesign the user interface to comply with the UI-Kit-7 ruleset.

Rollback functionality is limited to latest revision

Valid from Pega Version 7.1.7

The rollback functionality in DSM Revision Manager allows customers to roll back the import of the latest revision to their DSM application. Only one rollback is allowed; after a rollback, the rollback option is disabled until the next revision is imported. If importing two (or more) revisions at once then attempting a rollback, the system only rolls back one revision.

Example: a user has a base DSM application. They import Revision 1, and then import Revision 2. Next, they try to roll back both revisions. The system reverts to the Revision 1 version of the application, and the customer cannot revert all the way back to the base application.

System Management Application displaying listeners that do not require any action

Valid from Pega Version 7.1.7

After installing or upgrading to Pega 7.1.7, there is an additional available listener (Data-Decision-DNode-Service:Default) that does not require any action. This listener can be safely ignored and you should not use the System Management Application to manage any of its operations or state.

  • The Data-Decision-DNode-Service:Default listener is always running on every PRPC node.
  • The state of this listener is internally managed by PRPC. Starting or stopping it through SMA does not have any effect on its state.

Unable to create text analytics models when Java 2 Security is enabled

Valid from Pega Version 7.3

Security exceptions that prevent you from creating text analytics models are caused by the Java 2 Security feature that is enabled at the JVM level. This feature denies access to the text analytics resources that are required for text parsing functions.

Creating a text analytics model results in a failure because of a number of security-related exceptions, for example:

java.security.AccessControlException: Access denied ("java.lang.RuntimePermission""createSecurityManager")

The suggested approach for avoiding this problem is to use the text analytics models that are provided by default, for example, pySentimentModels, pyTelecomTaxonomy, and so on.

For more information, see Text Analyzer.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us