Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Cannot copy final section rules in UI Kit ruleset

Valid from Pega Version 7.1.6

You cannot copy section rules in the UI Kit ruleset (UI-Kit-71) that start with pz or px (final rules in the base PRPC rulesets).

Instead, to customize these rules, use the Copy/Merge Ruleset tool, available at Designer Studio >System > Tools > Refactor Rulesets, to copy all rules from the UI Kit into your application ruleset. You can then check the section rules in and out.

User interface distortions in the Decision Manager portal

Valid from Pega Version 7.1.6

By default, the New Application wizard in Pega 7.1.6 configures new applications to include UI-Kit-7 in the list of application rulesets. This ruleset causes user interface distortions in the Decision Manager portal. Both applications created in previous maintenance level updates and applications created in Pega 7.1.6 that do not include the UI-Kit-7 dependency are not impacted by this known issue.

Workaround:

  1. Open the application record.
  2. In Application Rulesets, remove UI-Kit-7.
  3. Save the application record.

User interface distortions in the Predictive Analytics Director portal

Valid from Pega Version 7.1.6

By default, the New Application wizard configures new applications to include UI-Kit-7 in the list of application rulesets. This ruleset causes user interface distortions in the Predictive Analytics Director portal. Applications created in maintenance level updates previous to Pega 7.1.6, and applications that do not include the UI-Kit-7 dependency, are not impacted by this known issue.

Workaround:

  1. Open the application record.
  2. In Application Rulesets, remove UI-Kit-7.
  3. Save the application record.

Microsof Internet Explorer 9 (IE9) may display a script error when clicking a Help button

Valid from Pega Version 7.1.6

A script error may be displayed when clicking a Help button when script error notification is turned on in the browser. As a work around, uncheck the Display a notification about every script error option in the Advanced tab of the Options dialog box in Microsoft Internet Explorer 9.

Unable to create text analytics models when Java 2 Security is enabled

Valid from Pega Version 7.3

Security exceptions that prevent you from creating text analytics models are caused by the Java 2 Security feature that is enabled at the JVM level. This feature denies access to the text analytics resources that are required for text parsing functions.

Creating a text analytics model results in a failure because of a number of security-related exceptions, for example:

java.security.AccessControlException: Access denied ("java.lang.RuntimePermission""createSecurityManager")

The suggested approach for avoiding this problem is to use the text analytics models that are provided by default, for example, pySentimentModels, pyTelecomTaxonomy, and so on.

For more information, see Text Analyzer.

Tags disappear from Rich Text Editor source mode

Valid from Pega Version 8.5

When you use Rich Text Editor in HTML source mode, some tags disappear from the markup, which causes backward compatibility issues and data loss.

Cause

Pega Platform™ version 8.5.5 introduced the DOM Purifier security plugin. The plugin removes potentially vulnerable tags, including custom tags, from the raw HTML code in the Rich Text Editor source mode.

Workaround

You can disable the DOM Purifier plugin by adding the the window.disableDomPurifier = true markup to the userWorkForm HTML fragment rule.

Alternatively, as of Pega Platform version 8.5.6, you can add a tag to the allow list by including the window.rteCustomAllowedTags = ['myCustomTag'] snippet in the userWorkForm HTML fragment rule. 

In Pega Platform versions 8.5.6 to 8.6, the iframe tag is added to the allow list by default.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us