Automated Unit Testing is unavailable
Valid from Pega Version 7.1.1
Automated Unit Testing (AUT) is unavailable in 7.1.1 - 7.1.5.
Starting in 7.1.6, users can access AUT features from supported browser versions of IE.
IE8 limits expansion features
Valid from Pega Version 7.1.1
Internet Explorer 8 (IE8) does not support CSS media queries, which are used by re-expansion features in the Designer Studio. IE8 users with low screen resolution (800 x 600) and a small window size may find that the explorer area in the Designer Studio collapses but cannot re-expand.
As a work around, access the Designer Studio from another supported browser version and use the recommended, minimum screen resolution width of 1280 pixels.
Limited access for end user portals
Valid from Pega Version 7.1.1
The following portals are only accessible from supported versions of Internet Explorer in “quirks” mode:
- WorkUser
- WorkManager
Nesting dynamic containers not supported
Valid from Pega Version 7.1.1
Do not include a section containing a dynamic container inside of another dynamic container. This configuration may cause performance issues resulting in unexpected behavior at runtime, and is not supported.
Screenshot generation runs on local client
Valid from Pega Version 7.1.8
If you generate screenshots to include in your application document, this process still runs on your local client. Additionally, you are still required to use Internet Explorer to use this feature.
Warning message when opening server-generated documents
Valid from Pega Version 7.1.8
Depending on your system configuration, the following warning message might be displayed when you open a document that was generated on the server.
If you click
, certain content (for example, Table of Contents) is not populated in the document. Instead, click and save the document.The warning message that displays
Number and text input controls on Android devices may not display the correct keyboard
Valid from Pega Version 7.1.8
When running a Pega 7 application on a device using the Android operating system, pxNumber and pxTextInput controls may not display when using the desired on-screen keyboard. This happens when the number or text input type is set to number
.
At design time, the input type is selected in the Editable Format section of the Presentation tab in the Cell Properties panel for a pxNumber or pxTextInput control. Due to a known limitation in some versions of the Android OS running on some devices, the keyboard displayed at run time may not support entry of decimal values when a Number type keyboard is specified.
To resolve this issue, use the Phone
type when numbers with decimal values may be required. Using the Phone
type displays a numerical phone keyboard. The Android phone keyboard includes both commas and periods so that decimals may be entered.
The Phone type selected in the Presentation tab of a Number control
Note that this issue only occurs on Android devices. It is recommended that applications for iOS continue to use type=“Number”.
Decision Data Store data sets can be used only on DNodes
Valid from Pega Version 7.1.8
Data flows that contain Decision Data Store data sets as the primary or secondary source must be created and executed only on DNodes.
Data flows are not restarted automatically after application server restart
Valid from Pega Version 7.1.8
When you restart the application server or the Pega 7 server, you stop the execution of your data flows. The interrupted batch and real-time runs are marked as Failed.
Recommendation:
- Go to the > > > > tab and start the failed batch runs.
-
Go to the
> > > > tab and activate the failed real-time runs.
Value list and value group properties are not supported inside data flows
Valid from Pega Version 7.1.8
Value list and value group properties are not supported inside data flows, and you need to instead use other property types.
See the Pega 7 developer help to check all available property types.