Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

End of support for form-based rule forms in Pega 7.1.9

Valid from Pega Version 7.1.9

Rule forms that are configured to render as forms are no longer supported in Designer Studio or end-user applications. Form-based configurations are found on custom rule types that were created in earlier versions of Pega 7 and are characterized by pop-up windows that are rendered externally from Designer Studio.

Reconfigure Pega 7 applications that use such rule forms by using standard harnesses and sections.

  1. Open the class form.
  2. Click the Advanced tab.
  3. Select Harness from the Rule formmenu.
  4. Create a new harness and new sections that implement the logic of the custom rule, using standard user interface layouts and controls.

Migrating custom rule forms to harnesses and sections offers the following benefits:

  • User interfaces become HTML5 WC3 compatible and responsive to different screen sizes.
  • User interfaces become cross-browser compatible, rendered consistently in Google Chrome, Mozilla Firefox, Apple Safari, and recent versions of Microsoft Internet Explorer.
  • Rendering performance on modern browsers is dramatically improved.
  • User interface pop-up behavior is eliminated; all windows are rendered inside Designer Studio and end-user applications.

Search field type is deprecated

Valid from Pega Version 7.1.9

The search field type in Form Builder is deprecated. Use a data reference or user reference instead, both of which prompt users with an autocomplete field at run time.

For the full list of supported field types in Form Builder, see Supported display modes by field type.

New process for Pega Cloud customers to obtain BIX extract files

Valid from Pega Version 7.3

The process for obtaining Business Intelligence Exchange (BIX) extract and manifest files for Pega® Cloud customers has changed as a result of data security enhancements for HIPAA compliance. By default, after upgrading to Pega 7.3, you must obtain the BIX extract and manifest files from the Pega SFTP server. From within Designer Studio, you can configure the BIX extract and manifest files to be sent to a remote SFTP server by a file listener. For Pega Cloud customers who have purchased a Pega Cloud SFTP Server subscription, you can configure BIX to send the BIX extract and manifest files to the SFTP server's folders for remote SFTP client download.

For more information about obtaining files from the Pega SFTP server, see Obtaining BIX extract files from the Pega SFTP server.

For more information about having files sent to your SFTP server, see Defining SFTP-related data instances.

Requestor Management landing page access privileges

Valid from Pega Version 7.3

To access the Requestor Management landing page after upgrading to Pega® Platform 7.3, you need to add the appropriate privileges to the @baseclass and Pega-Landing access classes in the access roles. Apply these privileges to any application in which you want the operator to be able use the requestor management feature.

For more information, see the Requestor Management landing page and the appropriate Deployment Guide.

Pulse Extension points are deprecated

Valid from Pega Version 7.3

Beginning with Pega® Platform 7.3, Pulse uses the notifications feature to send notifications. As a result, Pulse extension points for email body, subject, and recipient list have been deprecated. Preferences set for Pulse notifications in earlier versions are no longer valid.

Use the alternatives listed in the following table to configure your Pulse message and notification preferences.

Deprecated extension pointAlternative extension pointCorresponding notification rule
pyInstantPulseNotification (Correspondence)pyAddPulsePost (Correspondence)pyAddPulsePost
pyReplyPulseNotification (Correspondence)pyAddPulsePost (Correspondence)pyAddPulsePost
pyMentionsPulseNotification (Correspondence)pyAddUserMentionedPost (Correspondence)pyAddUserMentionedPost
pyMentionsInNonCaseContext (Correspondence)pyAddUserMentionedPost (Correspondence)pyAddUserMentionedPost
pyNewPulsePostSubject (Field Value)pyAddPulsePostEmailSubject (Field Value)pyAddPulsePost
pyNewPulseFilePostSubject (Field Value)pyAddPulsePostEmailSubject (Field Value)pyAddPulsePost
pyNewPulseReplySubject (Field Value)pyAddPulsePostEmailSubject (Field Value)pyAddPulsePost
pyMentionedUserSubject (Field Value)pyAddUserMentionedPostEmailSubject (Field Value)pyAddUserMentionedPost
pyMentionedFollowerSubject (Field Value)pyAddUserMentionedPostEmailSubject (Field Value)pyAddUserMentionedPost
pyMentionedFollowerWithFilePostSubject (Field Value)pyAddUserMentionedPostEmailSubject (Field Value)pyAddUserMentionedPost
pyGetListOfEmailReceivers (Activity)D_pxGetCaseFollowers (Data page)pyAddPulsePost

To continue using the deprecated extension points, override the pyInvokepxNotify when rule and set it to return false.

For more information, see Management of user notification preferences.

Deprecated survey APIs

Valid from Pega Version 7.3

APIs that were available in the PegaSurvey ruleset have been superseded by Pega® Platform APIs. Although older APIs continue to function in this release, it is recommended that you update your flows and flow actions to use the new APIs because they provide the latest survey capabilities, and deprecated features are not supported.

The following table maps deprecated APIs to their replacement APIs.

Deprecated APINew APIDescription
Work-.QuestionShapeWork-.pzQuestionShapeA flow that displays one simple question.
Work-.QuestionShapeScrWork-.pzQuestionShapeScrA screen flow that displays one simple question.
Work-.SurveyDriverWork-.pxSurveyDriver

A flow that displays questions in a survey, which can be simple or complex.

You can control whether the questions are displayed on one or multiple screens.
Work-.SurveySectionWork-.pxSurveySection

A section that displays questions in a survey.

You can reference this section from a user action, such as a flow action or connector flow action, in a flow.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us