Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Gadget configuration by using IAC gateway console is no longer supported

Valid from Pega Version 7.2.1

The Internet Application Composer (IAC) gateway was deprecated in Pega Platform™ 7.2.1 and is no longer supported. The IAC was used to embed a Pega Platform application, such as a gadget, on the pages of a web application that was located on your intranet, extranet, or internet site.

Upgrade impact

After an upgrade to Pega Platform 8.5, the configuration of gadgets through the IAC gateway console is no longer supported.

What steps are required to update the application to be compatible with this change?

To make subsequent changes to your current web mashup, use Pega Web Mashup. 

For more information, see Tutorial: Creating a mashup with Pega Web Mashup.

Derby databases are no longer supported

Valid from Pega Version 7.1.8

Previously, an embedded Derby database could be used as a file system. This setup was configured by setting storage/class/<<filesystem>>/type to "embedded" in the prconfig file.

After upgrading, storage types that are specified as "embedded" now default to the local file system.

Deprecated rule types

Valid from Pega Version 7.1.8

The following rule types have been deprecated as of the Pega 7.1.8 release:

  • Form
  • Hierarchy
  • Service COM
  • Service BPEL
  • Connect BPEL
  • Parse Transform
  • Parse Transform Collection
  • Parse Infer

For more information, including suggested alternate rule types, see the help topic Deprecated features.

Configuration required for data operations on external schema when using a Postgres database

Valid from Pega Version 7.1.8

When you use the API for data operations on external schema in the Postgres database, you must update the prconfig.xml file. No other platform requires a prconfig.xml update.

To update the prconfig.xml file:

  1. Stop the server and add the following entry to the prconfig.xml file:
    env name="database/databases/postgres_ext/defaultSchema"
    value="externalschema"
    where postgres_ext is the external database that uses the external schema “externalschema”.
  2. Restart the server.

The UpdateAdaptiveModels agent causes an exception after Pega 7.2 to 7.2.1 upgrade

Valid from Pega Version 7.2.1

After the Pega 7 Platform is upgraded from version 7.2 to 7.2.1, the log files might show an error that is caused by the UpdateAdaptiveModels agent. This agent is enabled by default and is responsible for updating scoring models in the Pega 7 Platform. If you use adaptive models in your solution, you can avoid this error by configuring the Adaptive Decision Manager service. If you do not use adaptive models, disable the UpdateAdaptiveModels agent.

For more information, see Configuring the Adaptive Decision Manager service and Pega-DecisionEngine agents.

Reconfiguration of the Adaptive Decision Manager service after upgrade to Pega 7.2.1

Valid from Pega Version 7.2.1

After you upgrade the Pega 7 Platform to version 7.2.1, you need to reconfigure the Adaptive Decision Manager service. Beginning with Pega 7.2.1, the Adaptive Decision Management (ADM) service is native to the Pega 7 Platform and is supported by the Decision data node infrastructure.

For more information, see Services landing page.

Customizations to the prlogging.xml file must be manually ported after upgrade

Valid from Pega Version 7.3

As a result of the upgrade from the Apache Log4j 1 logging service to the Apache Log4j 2 logging service, the name of the logging configuration file has changed from prlogging.xml to prlog4j2.xml and the format of the file has changed considerably. If you customized your prlogging.xml file, port the customizations to the new prlog4j2.xml file. If you do not port the changes, the Pega® Platform uses the default prlog4j2.xml file and disregards your customized prlogging.xml file.

For more information about customizing your log files, see the Apache Log4j 2 documentation.

Socket server has changed for remote logging

Valid from Pega Version 7.3

As a result of the upgrade from the Apache Log4j 1 logging service to the Apache Log4j 2 logging service, the socket server that is used for remote logging has changed from the Log4j remote logging package with the LogFactor5 log analysis tool to TcpSocketServer. If you use remote logging, update your socket server to TcpSocketServer. For more information, see Installing and using remote logging.

New process for Pega Cloud customers to obtain BIX extract files

Valid from Pega Version 7.3

The process for obtaining Business Intelligence Exchange (BIX) extract and manifest files for Pega® Cloud customers has changed as a result of data security enhancements for HIPAA compliance. By default, after upgrading to Pega 7.3, you must obtain the BIX extract and manifest files from the Pega SFTP server. From within Designer Studio, you can configure the BIX extract and manifest files to be sent to a remote SFTP server by a file listener. For Pega Cloud customers who have purchased a Pega Cloud SFTP Server subscription, you can configure BIX to send the BIX extract and manifest files to the SFTP server's folders for remote SFTP client download.

For more information about obtaining files from the Pega SFTP server, see Obtaining BIX extract files from the Pega SFTP server.

For more information about having files sent to your SFTP server, see Defining SFTP-related data instances.

Requestor Management landing page access privileges

Valid from Pega Version 7.3

To access the Requestor Management landing page after upgrading to Pega® Platform 7.3, you need to add the appropriate privileges to the @baseclass and Pega-Landing access classes in the access roles. Apply these privileges to any application in which you want the operator to be able use the requestor management feature.

For more information, see the Requestor Management landing page and the appropriate Deployment Guide.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us