Source field not displaying in data transform

Valid from Pega Version 7.1.4

On the Data Transform rule form when using the Update Page action, if the Relation value is updated to “with values from”, the Source field will not be displayed.

(Note that for existing data transforms where the Source field has already been completed, this situation should not occur.)

Workaround

  1. Below is a data transform that has been configured to use Update Page.
    DataTransform1.jpg
  2. If a user were to choose an alternate source by updating the ‘with values from’ Relation value, they would not be prompted to provide a page name in the Source field.
    DataTransform2.jpg
  3. At this point, to be able to enter the Source page value, the user has to save the rule, which results in an error because the source page value is blank. This causes the field to appear.
    DataTransform3.jpg
  4. Once the field has appeared, the Source page value can be provided, and the form can be saved successfully.
    DataTransform4.jpg

Core Engine

Valid from Pega Version 7.1.4

This release contains fixes related to clipboard and declarative features, including data pages and autopopulate.

 

  • A rule may be changed using Private Checkout, and then checked into a higher RuleSet Version for that RuleSet.
  • Agents may now use a 24-hour time period for scheduling, as well as a 12-hour time period (which required the selection of AM or PM).
  • Caching and performance have been enhanced.
  • Declare expressions will work with embedded page lists when creating forms.
  • Mandatory parameters on a data page can handle blank values.
  • Properties may be auto-populated using a reference property which is created with a Property-Ref method in an activity.
  • System will use "private edit" rules in developer's personal RuleSet when that rule overrides the "standard" rule available to all.
  • The Page-Remove method will now remove Data Pages at the Thread level and the Requestor Level.
  • When copying a page using the "Set" action on a data transform, the Declare Indexes defined on that data will be updated.
  • When creating a data page, the Reload Once per Interaction checkbox can be checked to set the refresh strategy. 

DCO

Valid from Pega Version 7.1.4

This release focused on improving the user experience of creating new rules and tightening up the use of specifications in the Case Designer.  The layout of the New and Save As forms were made more intuitive and intelligent.  Specification actions were made to be more consistent across various aspects of the Case Designer.

  • After removing specification references, users can create and save a new specification.
  • Developers may now choose either an existing specification or create a new one for subflows and Split-For-Each shapes.
  • If a specification is not associated with flow shapes such as sub flows, Utilities, or Split-For-Each, it is possible to import speciications with the same names, and the flow shapes will default to using those imported specs.
  • In the outline view, specification changes will be preserved when switching from tab to tab.
  • The View Full Details functionality from either Configure Step or the Outline View will display all details, including the specification requirement links.

Designer Studio

Valid from Pega Version 7.1.4

Many refinements to the Designer Studio were made around performance and user experience. Based on feedback, we have made a number of bug fixes and strategic improvements that improve the overall user experience.

  • The Developer Portal connects to the PDN's RSS feed without needing a DigiCert certificate for validation. The RSS feed is just headlines; to open and read any of the articles, users will still have to log into the PDN.
  • Expression Builder has been enhanced to work with IE8.
  • New applications built in Version 7.1 will automatically redirect users to the PRPC login page upon logout. A new template has been added, to allow developers to customize their applications to redirect users to a logout page, if they wish.
  • Performance improvements were made when saving and validating rules.
  • Performance of the Guardrails Dashboard has been improved.
  • The display of circumstanced rules in Application Explorer has been enhanced.

User Interface

Valid from Pega Version 7.1.4

This release had a focus around improving support for accessibility for all the PRPC UI Components as well as extending capabilities for responsive design with grids and tabs. A series of cosmetic changes and fixes are included.

  • Improvements have been made for action items being opened in a dynamic container.
  • Row repeat functionality in sections has been improved to better handle source properties.
  • Screen layouts have been optimized for the iPhone platform
  • The display on dynamic containers has been enhanced to provide the same behavior for both single-mode and multi-mode.
  • The Launch Harness feature has been improved to launch into a pop-up window.
  • The operator menu will now display from the Case Manager portal.
  • The Primary Page functionality has been enhanced for control-defined Repeating Tab Headers.
  • Using local actions defined as modal windows has been enhanced to work in an iPAD using a Safari browser.
  • When using a modal dialog to open a flow action in a repeat grid, to add an item to the list, users may now cancel out of this dialog if no changes are needed.

Screenshot generation runs on local client

Valid from Pega Version 7.1.8

If you generate screenshots to include in your application document, this process still runs on your local client. Additionally, you are still required to use Internet Explorer to use this feature.

Warning message when opening server-generated documents

Valid from Pega Version 7.1.8

Depending on your system configuration, the following warning message might be displayed when you open a document that was generated on the server.

If you click No, certain content (for example, Table of Contents) is not populated in the document. Instead, click Yes and save the document.

Warning message dialog

The warning message that displays

Number and text input controls on Android devices may not display the correct keyboard

Valid from Pega Version 7.1.8

When running a Pega 7 application on a device using the Android operating system, pxNumber and pxTextInput controls may not display when using the desired on-screen keyboard. This happens when the number or text input type is set to number.

At design time, the input type is selected in the Editable Format section of the Presentation tab in the Cell Properties panel for a pxNumber or pxTextInput control. Due to a known limitation in some versions of the Android OS running on some devices, the keyboard displayed at run time may not support entry of decimal values when a Number type keyboard is specified.

To resolve this issue, use the Phone type when numbers with decimal values may be required. Using the Phone type displays a numerical phone keyboard. The Android phone keyboard includes both commas and periods so that decimals may be entered.

Cell Properties dialog

The Phone type selected in the Presentation tab of a Number control

Note that this issue only occurs on Android devices. It is recommended that applications for iOS continue to use type=“Number”.

Context-specific documentation is not available in express mode

Valid from Pega Version 7.1.9

Help topics that are opened from express mode display content that is specific to Designer Studio.

If your system is dedicated to applications that are developed in express mode exclusively, and you do not need Designer Studio help topics, you can set the Online Help URL field on the System Settings landing page to: https://pdn.pega.com/sites/default/files/help_p7e/procomhelpmain.htm. Alternatively, you can view the contextual help system for Pega 7 Express in a separate browser tab.

Design-time limitations in express mode

Valid from Pega Version 7.1.9

Some limitations apply when you develop an enterprise application in express mode. At design time, some features are disabled or have limited options when you configure them in Designer Studio and switch to express mode. The use of these features does not restrict the run-time behavior of your application; however, you cannot change the configuration of these features unless you switch from express mode to Designer Studio.

For more information about each limitation and the recommended action to take, see the following information:

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us