DCO and PMF integration is unavailable

Valid from Pega Version 7.1.5

DCO and PMF integration functionality is not available in this release. Related project management controls have been removed from the following:

  • System Settings landing page (Designer Studio > System > Settings > Project Management)
  • Application Profile landing page (Designer Studio > Application > Profile > Specifications)
  • Add/Edit Specification dialog

Restricted SMA access

Valid from Pega Version 7.1.5

System Management Application (SMA) remote connections are not supported on JBoss EAP 6.x. This means SMA users may only monitor locally connected systems. Ensure that the "Local JVM Connection..." option is selected when configuring PRPC nodes:

Cannot copy final section rules in UI Kit ruleset

Valid from Pega Version 7.1.6

You cannot copy section rules in the UI Kit ruleset (UI-Kit-71) that start with pz or px (final rules in the base PRPC rulesets).

Instead, to customize these rules, use the Copy/Merge Ruleset tool, available at Designer Studio >System > Tools > Refactor Rulesets, to copy all rules from the UI Kit into your application ruleset. You can then check the section rules in and out.

Text Input control number type does not validate

Valid from Pega Version 7.1.5

When a Text Input control type is set to "Number" in the Presentation tab:

  • Validation does not trigger and the field is blanked out when a user submits the form.
  • If a value other than a number is entered, the browser sends an empty value, and the value is not validated.
  • In the Clipboard, the field value displays as empty.
  • If the field is required, the validation displays.

This issue occurs when using both the Chrome and Safari web browsers, and is a result of browser behavior for the HTML5 type=“number”. To fix this issue when using these browsers, do not use the "Number" type in Presentation tab of a Text Input control. Instead, the type should be set to "Text".

Unclear error message when saving shared class instance in tenant layer

Valid from Pega Version 7.1.5

If you attempt to save a shared class instance from the tenant layer, Pega 7 displays this message:

This record has x errors. Save Failed: There was a problem saving an instance of class: Error Code: <none> SQL State: <none> Message: <none>

You cannot save a shared instance from the tenant layer if that instance cannot be overridden.

Microsof Internet Explorer 9 (IE9) may display a script error when clicking a Help button

Valid from Pega Version 7.1.6

A script error may be displayed when clicking a Help button when script error notification is turned on in the browser. As a work around, uncheck the Display a notification about every script error option in the Advanced tab of the Options dialog box in Microsoft Internet Explorer 9.

Context-specific documentation is not available in express mode

Valid from Pega Version 7.1.9

Help topics that are opened from express mode display content that is specific to Designer Studio.

If your system is dedicated to applications that are developed in express mode exclusively, and you do not need Designer Studio help topics, you can set the Online Help URL field on the System Settings landing page to: https://pdn.pega.com/sites/default/files/help_p7e/procomhelpmain.htm. Alternatively, you can view the contextual help system for Pega 7 Express in a separate browser tab.

Design-time limitations in express mode

Valid from Pega Version 7.1.9

Some limitations apply when you develop an enterprise application in express mode. At design time, some features are disabled or have limited options when you configure them in Designer Studio and switch to express mode. The use of these features does not restrict the run-time behavior of your application; however, you cannot change the configuration of these features unless you switch from express mode to Designer Studio.

For more information about each limitation and the recommended action to take, see the following information:

System starts slowly after upgrade or update on IBM DB2 for z/OS

Valid from Pega Version 7.2.2

Additional tables are added to upgraded and updated systems. If your system starts up very slowly after an upgrade or update, the database statistics on these new tables might not have generated correctly. To correct this issue and improve performance, your database administrator needs to manually rebuild the statistics for all tables in the rules schema.

Clustering equal to none might cause errors

Valid from Pega Version 7.2.2

Some Pega 7 Platform features might not work when theidentification/cluster/protocolsetting in the prconfig.xml file is set to none. Some features that might not work are remote tracing and management actions on the node from the Requestor Management and Agent Management landing pages. Setting the clustering protocol to none is not recommended and will not be supported in a future Pega 7 Platform release.