DCO and PMF integration is unavailable

Valid from Pega Version 7.1.5

DCO and PMF integration functionality is not available in this release. Related project management controls have been removed from the following:

  • System Settings landing page (Designer Studio > System > Settings > Project Management)
  • Application Profile landing page (Designer Studio > Application > Profile > Specifications)
  • Add/Edit Specification dialog

Restricted SMA access

Valid from Pega Version 7.1.5

System Management Application (SMA) remote connections are not supported on JBoss EAP 6.x. This means SMA users may only monitor locally connected systems. Ensure that the "Local JVM Connection..." option is selected when configuring PRPC nodes:

Cannot copy final section rules in UI Kit ruleset

Valid from Pega Version 7.1.6

You cannot copy section rules in the UI Kit ruleset (UI-Kit-71) that start with pz or px (final rules in the base PRPC rulesets).

Instead, to customize these rules, use the Copy/Merge Ruleset tool, available at Designer Studio >System > Tools > Refactor Rulesets, to copy all rules from the UI Kit into your application ruleset. You can then check the section rules in and out.

Text Input control number type does not validate

Valid from Pega Version 7.1.5

When a Text Input control type is set to "Number" in the Presentation tab:

  • Validation does not trigger and the field is blanked out when a user submits the form.
  • If a value other than a number is entered, the browser sends an empty value, and the value is not validated.
  • In the Clipboard, the field value displays as empty.
  • If the field is required, the validation displays.

This issue occurs when using both the Chrome and Safari web browsers, and is a result of browser behavior for the HTML5 type=“number”. To fix this issue when using these browsers, do not use the "Number" type in Presentation tab of a Text Input control. Instead, the type should be set to "Text".

ShowWarningOnForm is no longer processed

Valid from Pega Version 7.1.7

Rule forms now display all warnings, independent of category or type. The standard decision tree Embed-Warning.ShowWarningOnForm is no longer used to determine which warnings are visible.

You can safely remove any specialized versions of this rule in your application.

Use JDBC 4 compliant drivers for better performance

Valid from Pega Version 7.1.7

For better performance, ensure that you are using JDBC 4-compliant drivers.  For more information on supported and non-supported JDBC drivers, please reference the Platform Support Guide.

Use Tomcat 7 for better performance

Valid from Pega Version 7.1.7

For better performance with a Tomcat web server, use Tomcat 7.

Tomcat 6 has a limitation that causes the server to treat the JDBC driver as if it were a JDBC 3-compliant driver, even if the system is using a JDBC 4-compliant driver. Customers using Tomcat will see better performance if they upgrade to Tomcat 7 and use a JDBC 4-compliant driver.

Engine will not start if the incorrect JDBC driver is used

Valid from Pega Version 7.1.7

The engine will not start up if the incorrect JDBC driver is used. The following configurations are unsupported:

  • Using a Multi-tenant Oracle system with one of the Oracle JDBC drivers with issues (see the chart in the Platform Support Guide)
  • Using a Multi-tenant system with a JDBC 3 compliant driver, OR with Tomcat 6 (for more information on using tomcat with Pega 7.1.7, see Use Tomcat 7 for best performance)
  • Using Microsoft SQL Server with a JDBC 3 compliant driver, OR with Tomcat 6 (for more information on using tomcat with Pega 7.1.7, see Use Tomcat 7 for best performance)

When any of these unsupported configurations are encountered, Pega 7 will not start. Before this change, the engine would appear to start up properly, but would encounter issues during other parts of the engine startup or during actual use of the system.

IBM WebSphere Application Server V8: Edit the URL for Enabling System Management Application

Valid from Pega Version 7.1.7

WebSphere 8 does not correctly resolve the URL to enable System Management Application. As a workaround, when you configure the application server, you can do either of these actions:

  • Enter the full URL in the format:
    ​http://hostname:port/prsysmgmt/getnodes.action

  • Set the com.ibm.ws.webcontainer.redirectcontextroot property to true.

Open ports required for cluster communication

Valid from Pega Version 7.1.7

In a Pega 7 system, there can be multiple servers, or nodes, and each node can contain multiple JVMs.  In Pega 7.1.7, the port range 5701-5800 needs to be left open for cluster communication.   The number of available ports in this range needs to be greater than or equal to the greatest number of JVMs on any one node in the cluster.  So for example, if there are 3 JVMs on one node, and 7 JVMs on another node, there need to be at least 7 ports available.  By default, the system will begin with port 5701, and then look for the next port in the sequence (5702, followed by 5703).

 

If these ports are not available, you will see the following error:

 

ERROR   - PegaRULES initialization failed. Server: ABCDEF123

com.pega.pegarules.pub.context.InitializationFailedError: PRNodeImpl init failed

< . . . Java dump here . . . >

Caused by: com.hazelcast.core.HazelcastException: ServerSocket bind has failed. Hazelcast cannot start! config-port: <port>, latest-port: <port>

 

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us