Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

DCO and PMF integration is unavailable

Valid from Pega Version 7.1.5

DCO and PMF integration functionality is not available in this release. Related project management controls have been removed from the following:

  • System Settings landing page (Designer Studio > System > Settings > Project Management)
  • Application Profile landing page (Designer Studio > Application > Profile > Specifications)
  • Add/Edit Specification dialog

Stages and Steps may not appear as expected

Valid from Pega Version 7.1.5

There are some unique configurations of the newly enhanced pxDisplayStages gadget that can lead to case type "Stages and Steps" appearing more than once or not at all.  In the event that your application experiences one of these scenarios, the recommended work around is to relocate the gadget:

  • Add pxDisplayStages to the pyCaseContainer section (or equivalent)
  • Remove pxDisplayStages from the pyCaseActionArea section (or equivalent).

Text Input control number type does not validate

Valid from Pega Version 7.1.5

When a Text Input control type is set to "Number" in the Presentation tab:

  • Validation does not trigger and the field is blanked out when a user submits the form.
  • If a value other than a number is entered, the browser sends an empty value, and the value is not validated.
  • In the Clipboard, the field value displays as empty.
  • If the field is required, the validation displays.

This issue occurs when using both the Chrome and Safari web browsers, and is a result of browser behavior for the HTML5 type=“number”. To fix this issue when using these browsers, do not use the "Number" type in Presentation tab of a Text Input control. Instead, the type should be set to "Text".

Both Transfer and Transfer Assignment flow actions are displayed in the Bulk Actions tool

Valid from Pega Version 7.1.7

Both the deprecated Transfer flow action and its Pega 7.1.7 replacement Transfer Assignment (pyTransferAssignment) might appear in the Select Action menu on the Bulk Actions tool.

Either of the following situations can cause this behavior:

  • The original application did not contain the UI-Kit-7 ruleset, for example, the application was built on Pega 7.1.5.
    • The default flow actions are based on BulkProcessTransferFlowAction system settings.
    • If you add pyTransferAssignment as a local action in a case type rule, users will see both old and new actions.
    • The flow actions are still available unless you override the settings.
  • The upgraded application uses the UI Kit ruleset, but the Transfer local action was defined in the original case type rule and copied to the application.
    • The original is explicitly defined in the application.
    • pyTransferAssignment is available through the system settings in the UI Kit.

As a best practice, upgrade Transfer flow actions to Transfer Assignment in your flows and local actions. The UI Kit ruleset ensures that the new flow actions are optimized for mobile interfaces. In addition, Transfer Assignment provides multiple transfer functions (to manager, workbasket, advanced options) in a single form.

Alternatively, keep the original system settings so that the existing flow actions are still available.

Existing collections are deprecated

Valid from Pega Version 7.1.7

The original implementation of the Collection form is deprecated. Legacy instances in your application remain functional; however, any new instance you create uses the redesigned Collection form. Use the Decision category in the Records Explorer to view all collections available to you.

For guidance on upgrade limitations, see the Deprecated Collection form.

ShowWarningOnForm is no longer processed

Valid from Pega Version 7.1.7

Rule forms now display all warnings, independent of category or type. The standard decision tree Embed-Warning.ShowWarningOnForm is no longer used to determine which warnings are visible.

You can safely remove any specialized versions of this rule in your application.

Messages are rule resolved by class

Valid from Pega Version 7.1.7

As part of the Message form redesign, a class key part was introduced. While this key part is automatically handled as part of an upgrade or migration, it does change the available options you see in message SmartPrompts and how Rule-Message instances are rule resolved.

See Upgrade considerations for existing messages for more information.

Flow import functionality is limited to Microsoft Internet Explorer Version 9 and Version 10 in Pegasystems Public Format

Valid from Pega Version 7.1.7

Importing a flow in the Rule-from-File wizard is limited to Microsoft Internet Explorer 9 and Internet Explorer 10 in the Pegasystems Public Format .

Changes to archive.info in Pega 7.1.7

Valid from Pega Version 7.1.7

In Pega 7.1.7, the contents of the archive.info file have changed.

  • In versions Pega 7.1.6 and earlier, the archive.info file displays the build number of the Pega installation.
  • As of Pega 7.1.7, the build number no longer appears in the archive.info file.

In Pega 7.1.7, the archive.info file only displays a status message indicating whether or not the system is running, and the build number no longer appears. Instead, if the system is operational, the message “status=Running” displays in the archive.info file.

If there are any automated tests, scripts, or applications that rely on the archive.info file displaying the build number, those may fail and produce an error. It is recommended that any automation that relies on the build number displaying in the archive.info file be changed to look for the “status=Running” message.

Unclear error message when saving shared class instance in tenant layer

Valid from Pega Version 7.1.5

If you attempt to save a shared class instance from the tenant layer, Pega 7 displays this message:

This record has x errors. Save Failed: There was a problem saving an instance of class: Error Code: <none> SQL State: <none> Message: <none>

You cannot save a shared instance from the tenant layer if that instance cannot be overridden.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us