Source field not displaying in data transform

Valid from Pega Version 7.1.4

On the Data Transform rule form when using the Update Page action, if the Relation value is updated to “with values from”, the Source field will not be displayed.

(Note that for existing data transforms where the Source field has already been completed, this situation should not occur.)

Workaround

  1. Below is a data transform that has been configured to use Update Page.
    DataTransform1.jpg
  2. If a user were to choose an alternate source by updating the ‘with values from’ Relation value, they would not be prompted to provide a page name in the Source field.
    DataTransform2.jpg
  3. At this point, to be able to enter the Source page value, the user has to save the rule, which results in an error because the source page value is blank. This causes the field to appear.
    DataTransform3.jpg
  4. Once the field has appeared, the Source page value can be provided, and the form can be saved successfully.
    DataTransform4.jpg

ShowWarningOnForm is no longer processed

Valid from Pega Version 7.1.7

Rule forms now display all warnings, independent of category or type. The standard decision tree Embed-Warning.ShowWarningOnForm is no longer used to determine which warnings are visible.

You can safely remove any specialized versions of this rule in your application.

Noticeable differences between work objects created in the Decision Manager portal when compared to Designer Studio

Valid from Pega Version 7.1.7

In the Decision Manager portal, you create work objects by running flows in the enterprise application that serves as the base application for the application overlay. If the enterprise application does not include the UI-Kit-7 in its application rulesets, work objects can display differently in the Decision Manager portal when compared to Designer Studio because an application overlay is always configured to include the UI-Kit-7 ruleset.

Recommendation:

  1. Add the UI-Kit-7 ruleset dependency to the enterprise application.
  2. Redesign the user interface to comply with the UI-Kit-7 ruleset.

Offline mobile apps require Dynamic Container to use frameless Single Document mode

Valid from Pega Version 7.1.7

You can add a Dynamic Container (DC) directly into a Dynamic Layout cell. When creating a custom mobile app with offline capability, you must use the frameless Single Document mode of DC.

Note that mobile offline capability does not support using a framed Single Document mode.

Rollback functionality is limited to latest revision

Valid from Pega Version 7.1.7

The rollback functionality in DSM Revision Manager allows customers to roll back the import of the latest revision to their DSM application. Only one rollback is allowed; after a rollback, the rollback option is disabled until the next revision is imported. If importing two (or more) revisions at once then attempting a rollback, the system only rolls back one revision.

Example: a user has a base DSM application. They import Revision 1, and then import Revision 2. Next, they try to roll back both revisions. The system reverts to the Revision 1 version of the application, and the customer cannot revert all the way back to the base application.

System Management Application displaying listeners that do not require any action

Valid from Pega Version 7.1.7

After installing or upgrading to Pega 7.1.7, there is an additional available listener (Data-Decision-DNode-Service:Default) that does not require any action. This listener can be safely ignored and you should not use the System Management Application to manage any of its operations or state.

  • The Data-Decision-DNode-Service:Default listener is always running on every PRPC node.
  • The state of this listener is internally managed by PRPC. Starting or stopping it through SMA does not have any effect on its state.

Data entered in a new harness is lost after a sync operation

Valid from Pega Version 8.1

If you create a case in an offline-enabled application and enter data in a new harness, this data is lost after you click Submit and the sync operation takes place. For more information, see Offline capability and Enabling offline support for cases.