Screenshot generation runs on local client
Valid from Pega Version 7.1.8
If you generate screenshots to include in your application document, this process still runs on your local client. Additionally, you are still required to use Internet Explorer to use this feature.
Warning message when opening server-generated documents
Valid from Pega Version 7.1.8
Depending on your system configuration, the following warning message might be displayed when you open a document that was generated on the server.
If you click
, certain content (for example, Table of Contents) is not populated in the document. Instead, click and save the document.The warning message that displays
Number and text input controls on Android devices may not display the correct keyboard
Valid from Pega Version 7.1.8
When running a Pega 7 application on a device using the Android operating system, pxNumber and pxTextInput controls may not display when using the desired on-screen keyboard. This happens when the number or text input type is set to number
.
At design time, the input type is selected in the Editable Format section of the Presentation tab in the Cell Properties panel for a pxNumber or pxTextInput control. Due to a known limitation in some versions of the Android OS running on some devices, the keyboard displayed at run time may not support entry of decimal values when a Number type keyboard is specified.
To resolve this issue, use the Phone
type when numbers with decimal values may be required. Using the Phone
type displays a numerical phone keyboard. The Android phone keyboard includes both commas and periods so that decimals may be entered.
The Phone type selected in the Presentation tab of a Number control
Note that this issue only occurs on Android devices. It is recommended that applications for iOS continue to use type=“Number”.
Decision Data Store data sets can be used only on DNodes
Valid from Pega Version 7.1.8
Data flows that contain Decision Data Store data sets as the primary or secondary source must be created and executed only on DNodes.
Data flows are not restarted automatically after application server restart
Valid from Pega Version 7.1.8
When you restart the application server or the Pega 7 server, you stop the execution of your data flows. The interrupted batch and real-time runs are marked as Failed.
Recommendation:
- Go to the > > > > tab and start the failed batch runs.
-
Go to the
> > > > tab and activate the failed real-time runs.
Value list and value group properties are not supported inside data flows
Valid from Pega Version 7.1.8
Value list and value group properties are not supported inside data flows, and you need to instead use other property types.
See the Pega 7 developer help to check all available property types.
Data flow preview size is fixed to 10
Valid from Pega Version 7.1.8
The Preview option for each shape in data flows returns the first 10 records. This value is fixed and currently cannot be changed.
Data Flow transformation shapes cannot be used in combination with the Compose or Merge shapes
Valid from Pega Version 7.1.8
When you reference another data flow from a data flow that contains the Compose or shape, the referenced data flow cannot contain transformation shapes ( , , ).
Data flow validation does not currently prevent you from designing a data flow that goes against this design pattern. Make sure that your data flows follow this design pattern by checking the referenced and referencing data flows.
Data flow destination is resolved at assembly time
Valid from Pega Version 7.1.8
Data flow execution always uses the design-time destination data sets or destination data flows, regardless of the input records at run time.
Example:
You create a data flow and set the destination to a specific data set. In the data flow, you use a strategy that produces some results. Regardless of these results, the execution of your data flow always uses the destination data set that you specified when you designed the data flow.
The same applies when you set the destination to a data flow.
Context-specific documentation is not available in express mode
Valid from Pega Version 7.1.9
Help topics that are opened from express mode display content that is specific to Designer Studio.
If your system is dedicated to applications that are developed in express mode exclusively, and you do not need Designer Studio help topics, you can set the Online Help URL field on the System Settings landing page to: https://pdn.pega.com/sites/default/files/help_p7e/procomhelpmain.htm. Alternatively, you can view the contextual help system for Pega 7 Express in a separate browser tab.