Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Custom database (DB) triggers are dropped during upgrade

Valid from Pega Version 7.1.8

The latest version of Pega 7 improves performance by no longer using database triggers to assist with System Pulse and Data-Rule-Summary processing, which is now done within the Pega 7 engine. As a result, DB triggers are no longer installed on either the pr_sys_updatescache or pr4_rule_vw tables.

When upgrading to the latest version of Pega 7, if you had previously implemented a custom database (DB) trigger on these tables, or a custom DB trigger that refers to these tables, it is removed during the upgrade process. No custom triggers are removed unless they reference these tables.

If you have custom DB triggers that reference the pr_sys_updatescache or pr4_rule_vw tables and perform other processing, those triggers must be reimplemented. When doing so, you must be careful to not modify the pr_sys_updatescache or pr4_rule_vw tables.

For more information, see Startup check removes custom DB triggers.

Schema not found error when importing a Rule-Admin-Product file

Valid from Pega Version 7.1.8

If you import a Rule-Admin-Product file (RAP) file that includes a schema that has a view, grammar parsing changes can mean that the Pega 7 Platform is unable to find the schema.

To enable the Pega 7 Platform to find the schema:

  1. Review the error message that indicates that the schema was not found and identify the following items:
    • The name of the schema that is causing the error
    • The table name in the format: wrong_schema_name.table_name...
    • The DDL that the Pega 7 Platform is trying to apply
  2. Use the table name to identify the correct schema name in your system. This schema is usually your data schema, but might also be an external database.
  3. Download the DDL.
  4. Correct the schema name and save the DDL.
  5. Manually apply the DDL.

End of support for Netscape Plugin API in Google Chrome 45

Valid from Pega Version 7.1.8

Beginning with Chrome 45, which is expected to be available in September 2015, Google is ending support for browser plug-ins that rely on the Netscape Plugin API (NPAPI) architecture. These plug-ins include Microsoft Silverlight, Adobe Flash Player, and Java.

The Pega 7 Platform includes several optional features that use these plug-ins. For a detailed overview of these features, see Client-side technologies.

WebSphere log error with Java 8 for Enterprise JavaBeans

Valid from Pega Version 7.1.8

For environments that are deployed by using Java 8 on IBM WebSphere Application Server version 8.5.5.9 through the last 8.5.5.x fix pack, the log might report that a class was not found when the application server attempts to start Enterprise JavaBeans. If Java EE functionality is not needed, no further action is required. However, to use Enterprise JavaBeans, see WebSphere log error with Java 8 for Enterprise JavaBeans.

Apache Ignite is no longer supported

Valid from Pega Version 8.1

Apache Ignite is no longer supported and has been replaced by Hazelcast Enterprise Edition 3.10 in embedded mode. If you used encryption with Apache Ignite, you can configure encryption on Hazelcast Enterprise Edition in the same way that you configured it for Apache Ignite.

For more information about encrypting nodes, see Enabling encrypted communication between nodes.

New roles required for system management features and APIs after upgrade

Valid from Pega Version 8.1

The pzSystemOperationsObserver and pzSystemOperationsAdministator privileges are no longer used for accessing system management features in Admin Studio and for system management APIs. Pega Platform™ has new privileges for individual system management functions and new roles configured with these privileges. Use the following roles to access system management features and APIs:

  • PegaRULES:SysOpsAdministrator – has all administrator and observer privileges
  • PegaRULES:SysOpsObserver – has all observer privileges
  • PegaRULES:SysAdm4 – has all administrator and observer privileges

After upgrading, you can include one or more of these roles in your access group or create a custom role. For more information about access roles, see Access roles.

Enabling access to upgraded help

Valid from Pega Version 8.1

After upgrading to Pega Platform ™ 8.1, the default URL to the upgraded help files might be incorrect. To enable access to the latest help files, reset the URL:

  1. In the header of Dev Studio, click Configure > System > Settings > URLs.
  2. Enter the Online Help URL:
    https://community.pega.com/sites/default/files/help_v81/
  3. Click Save.
  4. Log out and log back into Pega Platform.
Note: If client browsers on your network are restricted from Internet access for security reasons, you can also follow these steps to set the Online Help URL to a location on your local host.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us