Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

DB2-LUW database logfile size increase

Valid from Pega Version 7.1.5

This issue applies to DB2-LUW database platforms only.
 

To avoid running out of logfile space due to large transaction sets during the rule base load of a Pega 7.1.x install, upgrade, or maintenance level update, systems supported by a DB2-LUW database platform should increase the LOGFILSIZ parameter to at least 4096 pages from the default size of 1000 pages.

After the size has been increased, restart the database to ensure that the new setting is loaded into the database correctly.

Need to run script before updating Multitenant systems

Valid from Pega Version 7.1.5

When updating or upgrading a Multitenant system from Pega 7.1.5 or 7.1.6 to Pega 7.1.7, if that system uses either an Oracle or a PostgreSQL database, you may encounter the error:

“Table must be empty to add column.”

The Multitenant architecture requires an additional column on a number of the PRPC database tables (“pzTenantID”). In Pega 7.1.7, two additional PRPC tables were tenant-qualified: pc_schedule_task and pr_index_schedule_task. The Multitenant column is added to these tables by the update/upgrade process. However, Oracle and PostgreSQL do not allow the addition of a non-null column to an existing table unless the table is empty, so updating or upgrading systems on those databases displays the error detailed above.

To avoid this error, before beginning the update or upgrade, it is necessary to run a script:

  • OracleOracleMTupgrade.sql
  • PostgreSQLPostgresMTupgrade.sql

For updates, these scripts are located in the /scripts/ddl directory.

For upgrades, these scripts are located in the /Resourcekit/AdditionalUpgradeScripts directory.

Custom database (DB) triggers are dropped during upgrade

Valid from Pega Version 7.1.8

The latest version of Pega 7 improves performance by no longer using database triggers to assist with System Pulse and Data-Rule-Summary processing, which is now done within the Pega 7 engine. As a result, DB triggers are no longer installed on either the pr_sys_updatescache or pr4_rule_vw tables.

When upgrading to the latest version of Pega 7, if you had previously implemented a custom database (DB) trigger on these tables, or a custom DB trigger that refers to these tables, it is removed during the upgrade process. No custom triggers are removed unless they reference these tables.

If you have custom DB triggers that reference the pr_sys_updatescache or pr4_rule_vw tables and perform other processing, those triggers must be reimplemented. When doing so, you must be careful to not modify the pr_sys_updatescache or pr4_rule_vw tables.

For more information, see Startup check removes custom DB triggers.

End of support for Netscape Plugin API in Google Chrome 45

Valid from Pega Version 7.1.8

Beginning with Chrome 45, which is expected to be available in September 2015, Google is ending support for browser plug-ins that rely on the Netscape Plugin API (NPAPI) architecture. These plug-ins include Microsoft Silverlight, Adobe Flash Player, and Java.

The Pega 7 Platform includes several optional features that use these plug-ins. For a detailed overview of these features, see Client-side technologies.

End of support for Microsoft Internet Explorer 9 in Pega 7.2.1

Valid from Pega Version 7.2.1

In accordance with Microsoft’s announcement to discontinue support for Internet Explorer 9, Pega 7.2.1 will not support Internet Explorer 9. You should not upgrade to Pega 7.2.1 if you are still using Internet Explorer 9. Otherwise, upgrade to Microsoft Internet Explorer 10 or later, or use Google Chrome, Apple Safari, or Mozilla Firefox, which support certain HTML5 and CSS3 standards not supported in Internet Explorer 9.

For more information about browser support, see the Platform Support Guide or contact Pegasystems Global Customer Support.

 

 

 

Discontinued support for multithreaded requestors

Valid from Pega Version 7.2.1

Multithreaded requestors are no longer supported in the Pega 7 Platform. Multithreading was previously specified by the prconfig setting initialization/allowMultiplePRThreads. If this setting is set to true when you upgrade to Pega 7.2.1, errors occur during the quiesce process.

Child case queries can be slow after upgrade

Valid from Pega Version 7.2.1

After upgrading, performance might be slow when you run queries on child cases for work tables that existed prior to the upgrade. This issue is often indicated by PEGA0005 (query time exceeded limit) alerts that can be correlated to these queries in the logs. To resolve the issue, add a database index to each of your work tables by using a multicolumn index on the pxCoverInsKey, pxObjClass, and pyStatusWork columns.

For more information, see Performance improvements for child case queries.

Existing operator IDs during upgrades and updates

Valid from Pega Version 7.2.2

Upgrades and updates are always performed in secured mode to help prevent unauthorized access to your system. In secured mode, the [email protected] operator ID is always overwritten, but other existing standard operator IDs are not modified. New operator IDs are inserted in secured mode. For more information, see the Deployment Guide for your environment.

BIX -I command-line option fails for unexposed properties

Valid from Pega Version 7.2.2

Business Intelligence Exchange (BIX) command-line extractions fail when the extract has a filter that uses unexposed property references that are passed in by the input file that you specified in the -I command-line option. Previously, the BIX extraction ignored the filter and the extraction did not fail.

Rules Assembly cache is deprecated

Valid from Pega Version 7.3.1

Rules Assembly (RA) cache and custom settings for its corresponding fua/assemblyCacheModeprconfig.xml file setting are deprecated because they are obsolete. A warning is logged at startup if a custom (non-default) value is specified for fua/assemblyCacheMode in the prconfig.xml file. The functional behavior of the system is not affected.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us