DB2-LUW database logfile size increase

Valid from Pega Version 7.1.5

This issue applies to DB2-LUW database platforms only.
 

To avoid running out of logfile space due to large transaction sets during the rule base load of a Pega 7.1.x install, upgrade, or maintenance level update, systems supported by a DB2-LUW database platform should increase the LOGFILSIZ parameter to at least 4096 pages from the default size of 1000 pages.

After the size has been increased, restart the database to ensure that the new setting is loaded into the database correctly.

Need to run script before updating Multitenant systems

Valid from Pega Version 7.1.5

When updating or upgrading a Multitenant system from Pega 7.1.5 or 7.1.6 to Pega 7.1.7, if that system uses either an Oracle or a PostgreSQL database, you may encounter the error:

“Table must be empty to add column.”

The Multitenant architecture requires an additional column on a number of the PRPC database tables (“pzTenantID”). In Pega 7.1.7, two additional PRPC tables were tenant-qualified: pc_schedule_task and pr_index_schedule_task. The Multitenant column is added to these tables by the update/upgrade process. However, Oracle and PostgreSQL do not allow the addition of a non-null column to an existing table unless the table is empty, so updating or upgrading systems on those databases displays the error detailed above.

To avoid this error, before beginning the update or upgrade, it is necessary to run a script:

  • OracleOracleMTupgrade.sql
  • PostgreSQLPostgresMTupgrade.sql

For updates, these scripts are located in the /scripts/ddl directory.

For upgrades, these scripts are located in the /Resourcekit/AdditionalUpgradeScripts directory.

New process for Pega Cloud customers to obtain BIX extract files

Valid from Pega Version 7.3

The process for obtaining Business Intelligence Exchange (BIX) extract and manifest files for Pega® Cloud customers has changed as a result of data security enhancements for HIPAA compliance. By default, after upgrading to Pega 7.3, you must obtain the BIX extract and manifest files from the Pega SFTP server. From within Designer Studio, you can configure the BIX extract and manifest files to be sent to a remote SFTP server by a file listener. For Pega Cloud customers who have purchased a Pega Cloud SFTP Server subscription, you can configure BIX to send the BIX extract and manifest files to the SFTP server's folders for remote SFTP client download.

For more information about obtaining files from the Pega SFTP server, see Obtaining BIX extract files from the Pega SFTP server.

For more information about having files sent to your SFTP server, see Defining SFTP-related data instances.

Node types renamed after upgrade from Pega 7.2.2 to Pega Platform 7.3

Valid from Pega Version 7.3

If you used node classification in Pega® 7.2.2, when you upgrade to Pega 7.3, node type names are automatically changed to a new name when you start a node with a node type.

  • UniversalNode becomes Universal
  • WebUserNode becomes WebUser
  • BackgroundProcessingNode becomes BackgroundProcessing
  • BIXNode becomes BIX
  • SearchNode becomes Search

If you created agents in Pega 7.2.2, agent schedules are also automatically updated with a new name during the upgrade. For more information, see Customized agent schedules for standard Pega Platform agents must be updated after Pega 7.2.2 to Pega Platform 7.3 upgrade and the appropriate Deployment Guide.

Rollover policy for log files

Valid from Pega Version 7.3

The rollover policy for log files is now based on time (daily) and file size (maximum file size is 250 MB). Log files are rolled over daily or when the maximum file size is reached. Current (not rolled over) log files do not have a time stamp. The time stamp is added when the log file is rolled over. In addition, the log file name for the current log file does not include the date. You can add the date to the current log file; however, the log file will not be rolled over. In addition, the web.temdir variable for setting the log file location is no longer supported; use the pega.logdir variable instead.

For more information, see Pega Platform logging with the Log4j 2 logging service.

Customized agent schedules for standard Pega Platform agents must be updated after Pega 7.2.2 to Pega Platform 7.3 upgrade

Valid from Pega Version 7.3

If you used node classification in Pega® 7.2.2, when you upgrade to Pega 7.3, node type names are automatically changed to a new name when you start a node with a node type. Agent schedules for standard Pega Platform agents are deleted and re-created with the new node type name, but any customization that you made in Pega 7.2.2 is not saved. You must manually update the agent schedules for standard Pega Platform agents in Pega 7.3.

For more information, see Node types renamed after upgrade from Pega 7.2.2 to Pega Platform 7.3 and the appropriate Deployment Guide.

Apache Ignite is no longer supported

Valid from Pega Version 8.1

Apache Ignite is no longer supported and has been replaced by Hazelcast Enterprise Edition 3.10 in embedded mode. If you used encryption with Apache Ignite, you can configure encryption on Hazelcast Enterprise Edition in the same way that you configured it for Apache Ignite.

For more information about encrypting nodes, see Enabling encrypted communication between nodes.

New roles required for system management features and APIs after upgrade

Valid from Pega Version 8.1

The pzSystemOperationsObserver and pzSystemOperationsAdministator privileges are no longer used for accessing system management features in Admin Studio and for system management APIs. Pega Platform™ has new privileges for individual system management functions and new roles configured with these privileges. Use the following roles to access system management features and APIs:

  • PegaRULES:SysOpsAdministrator – has all administrator and observer privileges
  • PegaRULES:SysOpsObserver – has all observer privileges
  • PegaRULES:SysAdm4 – has all administrator and observer privileges

After upgrading, you can include one or more of these roles in your access group or create a custom role. For more information about access roles, see Access roles.

Enabling access to upgraded help

Valid from Pega Version 8.1

After upgrading to Pega Platform ™ 8.1, the default URL to the upgraded help files might be incorrect. To enable access to the latest help files, reset the URL:

  1. In the header of Dev Studio, click Configure > System > Settings > URLs.
  2. Enter the Online Help URL:
    https://community.pega.com/sites/default/files/help_v81/
  3. Click Save.
  4. Log out and log back into Pega Platform.
Note: If client browsers on your network are restricted from Internet access for security reasons, you can also follow these steps to set the Online Help URL to a location on your local host.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us