Split schema upgrade instructions missing properties

Valid from Pega Version 7.1.3

If you upgraded from 5.x, 6.x, or 7.x using the instructions in previous versions of the upgrade guide, you may have neglected to set the properties below in your migrateSystem.properties file when you migrated your upgraded schema to the source system:

 

pega.rules.objects.generate=true

pega.rules.objects.apply=true

 

If these properties were not set during an upgrade that splits the schema, your environment does not have the indexes, triggers, and primary keys on the rules tables.

 

To check for this issue, see if the pr4_base and pr4_rule rules tables in your existing rules schema are missing primary keys. If they are, use the SQL scripts in the ResourceKit\MigrationRecoveryScripts directory of the release to cleanup duplicate rules that were created due to this issue. Follow the steps below to run the scripts.

To run the scripts on Microsoft SQL, Oracle, or PostgreSLQ

  1. Take down any app servers using the affected schema.
  2. Backup your database.
  3. Replace all instances of @RULES_SCHEMA in <database>_cleanDups.sql with the name of the schema that contains the pr4_base table.
  4. Run the <database>_cleanDups.sql script on the database with vendor tools (sqlPlus, SQL Server Management Studio, etc).
  5. Replace all instances of @RULES_SCHEMA in <database>_fix_vw_table.sql with the name of the schema that contains the pr4_base table.
  6. Run the <database>_fix_vw_table.sql script on the database with vendor tools (sqlPlus, SQL Server Management Studio, etc).
  7. Generate and apply the ddl using the command line generateDDL command. Check the installation guide for your database or the upgrade guide for details about how to use the generateDDL command line script.
  8. Rebuild the indexes for the tables in your rules schema using vendor tools. This is necessary so that your system runs at an optimum speed.
  9. Optionally upgrade to the latest release, at this point your database is ready to be upgraded or used depending on your needs.

      

To run the scripts on DB2 for LUW or z/OS

  1. Take down any app servers using the affected schema.
  2. Backup your database.
  3. Run the <database>_cleanDups.sql script on the database with vendor tools (UDB CLP, Data Studio, etc) to create the CLEANSE_RULES_DUPS stored procedure.
  4. Run the query Call CLEANSE_RULES_DUPS(‘<rulesSchema>’); where <rulesSchema> is the name of schema that contains the pr4_base table.
  5. After the previous step is complete drop the CLEANSE_RULES_DUPS procedure.
  6. Replace all instances of @RULES_SCHEMA in <database>_fix_vw_table.sql with the name of the schema that contains the pr4_base table.
  7. Run the <database>_fix_vw_table.sql script on the database with vendor tools (UDB CLP, Data Studio, etc).
  8. Generate and apply the ddl using the command line generateDDL command. Check the installation guide for your database or the upgrade guide for details about how to use the generateDDL command line script.
  9. Rebuild the indexes for the tables in your rules schema using vendor tools. This is necessary so that your system runs at an optimum speed.
  10. Optionally upgrade to the latest release. At this point your database is ready to be upgraded or used depending on your needs.

Update Existing Applications wizard will run for every upgrade

Valid from Pega Version 7.1.7

The upgrade process from a PRPC 5.x or 6.x system to Pega 7.1.7 now automatically runs the Update Existing Applications wizard. This may extend the time that the upgrade process takes to complete, depending on the version you are upgrading from and the number of rules in your application.

Upgrading to Pega 7.1.7 with an Oracle database requires new role permissions

Valid from Pega Version 7.1.7

When upgrading or updating from a prior version to Pega 7.1.7, if your system uses an Oracle database, an additional role is required to support the Reversability functionality. In addition to the Oracle privileges specified in the Install Guides, the role SELECT_CATALOG_ROLE is required. Verify that this role is present before beginning the upgrade or update.

Add additional columns to customized work history tables

Valid from Pega Version 7.1.6

The standard work history table, pc_history_work, contains two new columns that return the latitude and longitude coordinate location of the action that prompted the history. Mobile devices can display this location as a street address. If you have a customized work history table, add these two columns to it:

  • <decimal name="pxLatitude" size="19" scale="9"/>
  • <decimal name="pxLongitude" size="19" scale="9"/>

Action required by admins for improved search

Valid from Pega Version 7.1.7

Starting November 13, 2014, after updating to or upgrading from a prior version to Pega 7.1.7, your system administrator must manually build all indexes for Elasticsearch before the system can automatically switch from Lucene to Elasticsearch.

It is recommended that you begin this manual re-indexing process for all enabled index types as soon as your update or upgrade is complete. The search landing page refers to Elasticsearch settings; during re-indexing, however, Lucene search continues to function to ensure that there is no interruption in search functions. When planning the re-indexing, be aware that the initial re-indexing requires significant resources on the host node and can be a lengthy process, depending on the number of rules and work objects in your system.

See the Pega 7.1.7 Upgrade Guide for information about manually indexing Elasticsearch.

Custom database (DB) triggers are dropped during upgrade

Valid from Pega Version 7.1.8

The latest version of Pega 7 improves performance by no longer using database triggers to assist with System Pulse and Data-Rule-Summary processing, which is now done within the Pega 7 engine. As a result, DB triggers are no longer installed on either the pr_sys_updatescache or pr4_rule_vw tables.

When upgrading to the latest version of Pega 7, if you had previously implemented a custom database (DB) trigger on these tables, or a custom DB trigger that refers to these tables, it is removed during the upgrade process. No custom triggers are removed unless they reference these tables.

If you have custom DB triggers that reference the pr_sys_updatescache or pr4_rule_vw tables and perform other processing, those triggers must be reimplemented. When doing so, you must be careful to not modify the pr_sys_updatescache or pr4_rule_vw tables.

For more information, see Startup check removes custom DB triggers.

Updates no longer require redeploying the prweb.war file or the application server-specific EAR file

Valid from Pega Version 7.1.7

Updating from Pega 7.1.7 to later versions of Pega 7 no longer requires that you redeploy the prweb.war file or the application server-specific EAR file.

Note that upgrades from versions prior to Pega 7.1.7 still require that you redeploy these files.

End of support for Netscape Plugin API in Google Chrome 45

Valid from Pega Version 7.1.8

Beginning with Chrome 45, which is expected to be available in September 2015, Google is ending support for browser plug-ins that rely on the Netscape Plugin API (NPAPI) architecture. These plug-ins include Microsoft Silverlight, Adobe Flash Player, and Java.

The Pega 7 Platform includes several optional features that use these plug-ins. For a detailed overview of these features, see Client-side technologies.

End of support for Microsoft Internet Explorer 9 in Pega 7.2.1

Valid from Pega Version 7.2.1

In accordance with Microsoft’s announcement to discontinue support for Internet Explorer 9, Pega 7.2.1 will not support Internet Explorer 9. You should not upgrade to Pega 7.2.1 if you are still using Internet Explorer 9. Otherwise, upgrade to Microsoft Internet Explorer 10 or later, or use Google Chrome, Apple Safari, or Mozilla Firefox, which support certain HTML5 and CSS3 standards not supported in Internet Explorer 9.

For more information about browser support, see the Platform Support Guide or contact Pegasystems Global Customer Support.

 

 

 

Discontinued support for multithreaded requestors

Valid from Pega Version 7.2.1

Multithreaded requestors are no longer supported in the Pega 7 Platform. Multithreading was previously specified by the prconfig setting initialization/allowMultiplePRThreads. If this setting is set to true when you upgrade to Pega 7.2.1, errors occur during the quiesce process.