Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Rules can no longer access Pega internal Java packages

Valid from Pega Version 8.4

You can no longer create rules that access Java packages that reference internal APIs (syntax com.pega.platform.*.internal*). This change does not affect rules that access Pega public API packages.

If you encounter issues when running existing rules that reference internal Pega APIs, contact Pega Support.

Upgrade impact

After an upgrade to 8.4 and later, clients can no longer save new or modified rules that access Pega internal APIs; existing rules that reference internal APIs can still be run but cannot be modified. 

What steps are required to update the application to be compatible with this change?

Following a software upgrade to 8.4 or later, clients can refactor existing rules into guardrail compliant rules. To find rules to refactor, run the validation tool from designer studio (Application > Tools > Validation) to identify what rules fail validation; failed rules that include the message "Test compilation failed : Illegal internal class reference : com.pega.internal.XYZ" can updated to reference appropriate APIs.

Split schema systems require additional privileges

Valid from Pega Version 7.1.2

On Oracle split schema systems, add the following database privileges:

  • Grant DROP ANY INDEX to the Admin User.
  • Grant UNLIMITED TABLESPACE to the Rules User.

Use the Oracle Enterprise Manager to add these privileges or refer to the 7.1.3 Upgrade and Installation guides for Oracle.

Data schema error on z/OS split schema upgrades from versions before Pega 7.1.8

Valid from Pega Version 4.1

When upgrading to a split schema on Pega 7.x with IBM DB2 for z/OS, you see an error during the data schema upgrade when the system tries to drop the PRPC_Updatescache procedure. Because triggers on rules tables use PRPC_Updatescache, you must use the ZOSDisableTriggerScripts to disable these triggers before you update the data schema.

  1. Follow the instructions in the Pega 7 Platform Upgrade Guide to upgrade the rules schema, but stop immediately before you upgrade the data schema with the upgrade.bat or upgrade.sh script. The Pega 7 Platform Upgrade Guide is on the Support > Deployment Guides page.
  2. Copy the contents of the <distribution>\ResourceKit\ZOSDisableTriggerScripts directory into the <distribution>\scripts\ directory.
  3. Run fixZosTriggers.bat or fixZosTriggers.sh with the following arguments:
    --action preupgrade
    --dataschema <data schema name>
    --oldrulesschema <old rules schema name. If you are upgrading from a single-schema system, this is the data schema name.>
    --newrulesschema <new rules schema name>
    --automaticddl <Optional. Set to true to automatically apply the disable trigger SQL scripts.>

    For example:
    fixZosTriggers --action preupgrade --dataschema pegadata --oldrulesschema pegarules --newrulesschema newrules --automaticddl false

  4. If you did not set --automaticddl to true in the previous step, run the <distribution>\schema/disable.sql script to manually disable the trigger SQL scripts.
  5. Run the data schema upgrade as described in the Pega 7 Platform Upgrade Guide.

Discontinued support for list view and summary view rules

Valid from Pega Version 7.2

The list view rule and the summary view rule are deprecated, and support for these rules has been discontinued. Existing list view and summary view reports will continue to work on supported browsers. However, the last version of Internet Explorer that list view and summary view rules support is Internet Explorer 11.

You cannot create new list view or summary view reports. Instead, create list reports and summarized reports by using the report definition rule. To prevent display issues, re-create the custom list view and summary view reports that you need as report definition reports.

End of support for Microsoft Internet Explorer 9 and Internet Explorer 10

Valid from Pega Version 7.2

In accordance with Microsoft’s announcement to discontinue support for Internet Explorer 9 and Internet Explorer 10 in January 2016, Pega 7.2 will be the last version of the Pega 7 Platform to support Internet Explorer 9 and Internet Explorer 10.  

For Pega 7.2.1, you must upgrade to Microsoft Internet Explorer 11 or later, or use Google Chrome, Apple Safari, or Mozilla Firefox.

For more information about browser support, see the Platform Support Guide or contact Pegasystems Global Customer Support.

Unused agents run in background

Valid from Pega Version 7.2

The Update PegaRULES database table statistics agent and the Collect PegaRULES database blob size statistics agent have been added to support future development. These agents run in the background, but they do not do anything. You can, but do not need to, disable them from the Edit Agent Schedule landing page.

For more information, see Agent Schedule form - Completing the Schedule tab.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us