Change logic does not work in Report Editor

Valid from Pega Version 7.1.2

The Report Editor​ change logic button does not work. As a workaround, use the rule form to change the logic.

List view and summary view reports might not display in HTML5-compliant browsers

Valid from Pega Version 7.1.7

List view and summary view reports use framesets to provide a view of drill-down reports. HTML5 does not support framesets, so these reports might not display well, or at all, in versions of browsers that are compliant with HTML5.

To prevent display issues, re-create the custom list view and summary view reports that you need as report definition reports. Standard management reports are already available as report definition reports.

As of Pega 7.2, list view and summary view rules are deprecated. For more information, see Discontinued support for list view and summary view rules.

Offline mobile apps require Dynamic Container to use frameless Single Document mode

Valid from Pega Version 7.1.7

You can add a Dynamic Container (DC) directly into a Dynamic Layout cell. When creating a custom mobile app with offline capability, you must use the frameless Single Document mode of DC.

Note that mobile offline capability does not support using a framed Single Document mode.

Cannot create new data tables after update

Valid from Pega Version 7.1.7

Data tables have been replaced by a new local data storage format. You can upgrade old-style data tables to use the new local data storage format, but the new format is not compatible with earlier versions of Pega 7 in which data tables could be created.

You can still edit legacy data tables by using the old data table functionality. However, to create new data tables, you must use the Data Explorer and Data Designer.

JavaMail API upgrade has potential SMTP configuration error

Valid from Pega Version 7.1.8

The JavaMail API has been upgraded from 1.4.1 to 1.5.2 in this release. This improvement provides greater compatibility and secure connectivity with leading industry email servers.

During the upgrade process, there is a known issue for some configurations of email servers, including Microsoft Exchange Server, that requires the use of an additional setting. After upgrading to this release, if you experience authentication failures when attempting to send email or test SMTP connectivity, do one of the following:

  • Recommended: Review the Microsoft Exchange email server settings to ensure proper configuration for SMTP authentication. In some cases, the use of port 587 instead of the traditional default SMTP port 25 has been shown to address this issue.
  • Create the following Dynamic System Setting with the value "true," and then restart email listeners:

Owning Ruleset: Pega-IntegrationEngine

Setting Purpose: javamail/NoAuthMechanismsRetry

After any email server configuration or upgrade, it is recommended that email listeners are re-tested without using this Dynamic System Setting.

See About Email Account data instances for information on configuring email account records.

The Create Build button appears grayed out when configuring and building a mobile application

Valid from Pega Version 7.1.8

When you attempt to configure and build your Android or iOS mobile application from the Mobile tab, the Create build button might appear dimmed. This issue occurs if any of the access roles in the access group were cloned from the PegaRULES:SysAdm4 access role.

Refer to Troubleshooting Pega Mobile Client to learn how to fix this issue in your application.

Offline configuration limitation

Valid from Pega Version 7.1.8

When enabling the offline capability for a case type, do not select the Enable offline check box in Case Designer because it incorrectly sets the locking strategy. Instead, select the Enable offline mode check box on the Advanced tab of the Case Type form.

To open the Case Type form from Case Designer, click Open on the Actions menu.

Creating data page unit tests in Internet Explorer 8

Valid from Pega Version 7.1.8

When creating data page unit tests, selecting a parent property does not automatically select the child properties when using Internet Explorer 8.

Page and page list properties to be included in a data page unit test are selected on the Create test screen by selecting a check box next to the property name. Normally, selecting the check box of a parent property automatically selects all subsequent child properties as well. When using Internet Explorer 8, child properties are not automatically selected when the parent property's check box is selected.

The solution requires selecting all of the desired child properties individually. Select the check box next to each child property to include it in the data page unit test.

Precision of Oracle Timestamp property when using RDB-Save

Valid from Pega Version 7.1.8

DateTime properties that are mapped to an Oracle Timestamp column will experience a loss of precision when they are saved using the RDB-Save method. When you use RDB-Save for an Oracle Timestamp, precision will be accurate to the second. For example, a value of 20171119T124745.006 will be saved as 20171119T124745. When you use Obj-Save, precision will be accurate to the millisecond. For more information, see DateTime property mapping in Oracle for Pega 7.