Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Unit testing support for more rule types

Valid from Pega Version 8.3

You can now create unit tests for the following additional rule types. You can also create assertions to validate activity status. The expanded rule types for unit testing enable developers to more thoroughly perform regression testing of their application, thereby improving application quality.

  • Collection
  • Declare expression
  • Map value
  • Report definition

For more information about unit testing rules, see Pega unit test cases.

Upgrade impact

With the four new rule types, unit test execution and unit test compliance metrics will change. Reports on automated unit testing of the customer application decrease due to the increased pool of supported rules.

What steps are required to update the application to be compatible with this change?

After a successful upgrade, create Pega unit test cases for the newly supported rules to see updated and accurate unit test metrics.

Improved case auditing in App Studio

Valid from Pega Version 8.5

In Cosmos UI, App Studio now supports expandable case steps. This enhancement helps users quickly navigate a case and provides deeper insight into the case flow. In addition, Cosmos UI also introduces an improved history view that helps you better meet your business auditing requirements.

For more information, see Managing Cosmos UI settings in case designer.

Upgrade impact

After an upgrade to Pega Platform 8.5 or later, the history and chevron designs change automatically. However, applications with custom history settings might still display the styling that you defined in the override.

What steps are required to update the application to be compatible with this change?

If your application uses custom settings and you want to use the updated history, remove the overrides from the pyWorkCommonActions rule.

Removal of Pega Mobile Client 7

Valid from Pega Version 8.5

You can now use a single Pega Mobile Client™ that improves app performance, app development, and meets all your mobile needs. With the introduction of new functionalities for mobile apps, Pega Mobile Client 7 is removed in Pega Platform™ 8.5.

Upgrade impact

After an upgrade to Pega 8.5, you can no longer build mobile apps based on Pega Mobile Client 7, and existing apps based on Pega Mobile Client 7 no longer connect to Pega Platform. App developers can now configure mobile apps with Pega Mobile Client.

What steps are required to update the application to be compatible with this change?

Existing clients that upgrade to Pega 8.5 are automatically switched to Pega Mobile Client.

Web portal reuse removed from the mobile channel

Valid from Pega Version 8.5

The reuse of web portals for creating mobile apps with a single web view is no longer supported. You can conveniently update your existing channels that reuse web portals to take advantage of the multiple-views experience and native mobile capabilities, such as native mobile list views or floating action buttons.

Upgrade impact

The Reuse web portal option is removed from Pega Platform 8.5 and later.

What steps are required to update the application to be compatible with this change?

App developers need to use the migration tool available on the mobile channel to move their apps to the recommended new navigation designer. When users open existing mobile channel with the Reuse web portal option configured, they are prompted to run through the wizard to upgrade the mobile channel to the latest Pega Mobile Client based configuration. When this is done, app developers should rebuild the app.

 

Tamper-proof Pega Web Mashup loading

Valid from Pega Version 8.5

To protect your application from hackers, Pega Web Mashup is now loaded in a more secure way. The system generates a channel ID in the mashup code for validation on the server, before passing the mashup request. 

For more information, see Creating a mashup.

Upgrade impact

After an upgrade to Pega Platform 8.5, existing mashups, which do not have the channel ID parameter in their code, cannot load and users see the access control warning.

What steps are required to update the application to be compatible with this change?

If you need to maintain full availability of the mashup during the upgrade of the production environment, perform the steps in Migrating existing mashups.

Native synchronization indicators for offline-enabled mobile apps

Valid from Pega Version 8.5

Offline-enabled mobile apps now include a set of native synchronization indicators. Indicators keep users informed about the data synchronization status, for example, the Syncing indicator appears when an app regains network connectivity and starts receiving responses from the server. You can customize the indicators to better suit the look and feel of your mobile app. For more information, see Customizing synchronization indicators.

Upgrade impact

After upgrading Pega Platform™ to version 8.5, your app does not include native synchronization indicators until you update your application to use UI-Kit 15.

What steps are required to update the application to be compatible with this change?

Update the UI Kit in your application to version 15. For more information, see Updating the UI Kit in your application.

Support for validations in Declare Expression rules

Valid from Pega Version 8.5

Pega Platform™ now correctly evaluates validations on target properties in Declare Expression rules. As a result, any validations defined on properties that have Declare Expression rules in previous releases, now work correctly. 

Upgrade impact

Any unintended validations on properties that have configured Declare Expression rules, both default and user-defined, might cause issues in an application upon saving work objects and data objects that refer to Declare Expression rules.

What steps are required to update the application to be compatible with this change? 

If you experience issues when saving objects, debug your application by setting the declareexp/target/validation/disable dynamic system setting to true. If your application works correctly after the change, it means that validations on Declare Expressions cause the issues. For your application to work correctly, analyze the log files and remove any unintended validations.

For more information, see Declare Expression rules.

pxFeed replaces pxContextFeed and pxActivityFeed Pulse gadgets

Valid from Pega Version 7.4

The pxContextFeed and pxActivityFeed gadgets have been replaced by the pxFeed gadget to integrate the functionalities of viewing and posting messages in the Pulse activity feed. You can include this gadget within a section or harness across your application, for example, in the dashboard of the Case Manager portal, to display the activity feed. You must add the latest UI Kit ruleset to ensure that your application uses the pxFeed gadget instead of the pxContextFeed and pxActivityFeed gadgets to generate the activity feed.

For more information, see Pulse gadget and custom APIs.

Survey rules are deprecated

Valid from Pega Version 7.4

Surveys that were created prior to version 7.4 of Pega Platform are now deprecated. As a best practice, recreate your survey by using the Survey Management landing page, and then reuse questions or question pages from your survey library.

For more information about creating surveys, see Improved survey authoring.

Questionnaire shape replaces Survey shape in legacy flows

Valid from Pega Version 7.4

In flows that reference deprecated surveys, the Questionnaire shape has replaced the Survey shape. Although legacy surveys continue to function in this release, update your flows to use the Survey shape because it provides the latest survey capabilities, and deprecated features are not supported.

For more information about the new survey authoring experience, see Improved survey authoring.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us