Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Text Input control number type does not validate

Valid from Pega Version 7.1.5

When a Text Input control type is set to "Number" in the Presentation tab:

  • Validation does not trigger and the field is blanked out when a user submits the form.
  • If a value other than a number is entered, the browser sends an empty value, and the value is not validated.
  • In the Clipboard, the field value displays as empty.
  • If the field is required, the validation displays.

This issue occurs when using both the Chrome and Safari web browsers, and is a result of browser behavior for the HTML5 type=“number”. To fix this issue when using these browsers, do not use the "Number" type in Presentation tab of a Text Input control. Instead, the type should be set to "Text".

Unclear error message when saving shared class instance in tenant layer

Valid from Pega Version 7.1.5

If you attempt to save a shared class instance from the tenant layer, Pega 7 displays this message:

This record has x errors. Save Failed: There was a problem saving an instance of class: Error Code: <none> SQL State: <none> Message: <none>

You cannot save a shared instance from the tenant layer if that instance cannot be overridden.

Ignore locale settings requires refresh after server restarts

Valid from Pega Version 7.2.1

The Ignore locale check box in operator preferences is selected to display Designer Studio in U.S. English. After a server restarts, screens initially ignore this setting. When the screen is refreshed or reopened, the screen is rendered as expected.

Flexbox-based dynamic layouts not supported for Android 4.4 and earlier

Valid from Pega Version 7.2.1

Flexbox-based dynamic layouts are not supported in Android 4.4 and earlier. When developing applications to be used on devices running Android 4.4 and earlier, use the inline-block layout mode for dynamic layouts.

Extension attributes are not supported in PMML models

Valid from Pega Version 7.3.1

Models in the Predictive Model Markup Language (PMML) format version 4.3 that contain extension attributes with the x- prefix are not valid. These extension attributes are deprecated; you must use extension elements instead. In addition, if the output type of any output field in the model is set to FLOAT, change it to DOUBLE.

For more information, see PMML 4.3 - General Structure in the Data Mining Group documentation.

The Upload responses action is not supported for adaptive models with customized context

Valid from Pega Version 7.3.1

A default instance of the Adaptive Model rule contains five model identifiers (.pyIssue, .pyGroup, .pyName, .pyDirection, .pyChannel) that are used to partition adaptive models. If you add other identifiers in your Adaptive Model rule instance, you cannot upload responses to this instance with the Upload Responses wizard and the following error is displayed: The Flow Action post-processing activity pzUploadCSVFile failed: Cannot parse csv file.You can still train such adaptive models with data flows.

For more information, see Training adaptive models in bulk with data flows, Model context, and Uploading customer responses.

Upgrading Adaptive Decision Manager data mart tables might fail

Valid from Pega Version 7.3.1

Issue: Upgrade from 7.3 to 7.3.1 fails if the data contained in the pxInsName column of the PR_DATA_DM_ADMMART_PRED_FACT table is longer than 128 characters.

Reason: During the Pega Platform™ upgrade from 7.3 to 7.3.1, data in the Adaptive Decision Manager (ADM) data mart tables is migrated from the PR_DATA_DM_ADMMART_PRED_FACT table to the PR_DATA_DM_ADMMART_MDL_FACT table. In Pega 7.3.1, ADM uses only the PR_DATA_DM_ADMMART_MDL_FACT table where the pxInsName property can store values that are 128 characters long. In Pega Platform 7.3, the pxInsName property in the PR_DATA_DM_ADMMART_PRED_FACT table can store values that are 255 characters long. If the pxInsName property contains values that are longer that 128 characters, the upgrade fails.

Resolution: Issue an ALTER TABLE statement to change the pxInsName column size to 255 characters and resume the upgrade. For example:

ALTER TABLE rules.pr_data_dm_admmart_pred ALTER COLUMN pxInsName TYPE varchar(255);

For more information, see Adaptive Decision Manager data model.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us