Turn off saved connections in WebLogic

Valid from Pega Version 7.1.1

PRPC caches connections in thread-local storage. When using a WebLogic application server, set database/savedconnections to FALSE to avoid incorrectly saved, container-managed transactions. You can make this update through JNDI settings or by adding an entry to the prconfig.xml, for example:

<env name="database/savedconnections" value="false" />

Automated Unit Testing is unavailable

Valid from Pega Version 7.1.1

Automated Unit Testing (AUT) is unavailable in 7.1.1 - 7.1.5.

Starting in 7.1.6, users can access AUT features from supported browser versions of IE.

IE8 hangs on large imports

Valid from Pega Version 7.1.1

IE8 users may experience a hung process when running the Designer Studio > Application > Distribution > Import wizard. This issue is related to low-capacity networks and large (300+ MB) archive files.

Although the processing symbol prevents you from proceeding to the next step in the wizard, the file is still imported to the server. As a workaround, you can:

  1. Wait approximately eight minutes for the file to import.
  2. Close and restart the wizard.
  3. Click Next to skip the upload step.
  4. Select the name of your file from the list of import files.
  5. Complete the remaining steps in the wizard.

Required DB2 settings

Valid from Pega Version 7.1.1

For customers using the DB2 Version 4 drivers (“db2jcc4.jar”), it is necessary to set the custom connection property useJDBC4ColumnNameAndLabelSemantics to “false”.   

For customers using DB2 with WebSphere, the useJDBC4ColumnNameAndLabelSemantics property in the DB2 data source needs to be changed from a Boolean to an Integer and set to "2". 

IE8 limits expansion features

Valid from Pega Version 7.1.1

Internet Explorer 8 (IE8) does not support CSS media queries, which are used by re-expansion features in the Designer Studio. IE8 users with low screen resolution (800 x 600) and a small window size may find that the explorer area in the Designer Studio collapses but cannot re-expand. 

As a work around, access the Designer Studio from another supported browser version and use the recommended, minimum screen resolution width of 1280 pixels.

Using Kerberos authentication with your database

Valid from Pega Version 7.1.1

Pega 7 supports Kerberos functionality. Kerberos is a computer network authentication protocol which allows nodes communicating over a non-secure network to prove their identity to one another in a secure manner. 

 

To use Kerberos for authentication, you must use the command line to install or upgrade Pega 7.

 

To use Kerberos authentication:

1.  Change the setupDatabase.properties file.

a.  In the “Uncomment this property section” of the file, uncomment the jdbc.custom.connection.properties property.  Based on your security infrastructure, different properties may be required as parameters to this property; provide the needed properties as semicolon-delimited name/value pairs:
 

jdbc.custom.connection.properties=prop1=val1;prop2=val2;prop3=val3;
 

Example:  For an installation on a MSSQL database server from a Windows client machine (where both machines belong to the same Windows domain), using the Microsoft JDBC driver, the property may be set as follows:
 

jdbc.custom.connection.properties=integratedSecurity=true;

 

b.  Comment out all the username and password properties where they occur in the jdbc.custom.connection.properties file, so that they appear as follows:


# pega.jdbc.username db username
# pega.jdbc.password db password

[lines removed here]

# pega.jdbc.username=ADMIN
# pega.jdbc.password=ADMIN

 

2.  Set up your database to enable Kerberos functionality.  This may include additional vendor-specific JDBC driver configuration, or other setup procedures.  Check the documentation from your database vendor to determine what Kerberos setup is needed for your database.

 

3.  Run the command line installation or upgrade by following the instructions found in the Pega 7 Deployment guides.

When using Oracle 12.1.0.1, left outer joins in reports may return incorrect results

Valid from Pega Version 7.1.1

When using  Pega 7 with Oracle 12.1.0.1 , reports that use left outer joins may return incorrect results.

This is an Oracle known issue.  To resolve this behavior, upgrade to Oracle 12.1.0.2, apply the Oracle patch 16726638 by requesting it directly from Oracle, or, for Microsoft Windows installations, apply Windows Bundle patch 12.1.0.1.15 or later.

For more information in this behavior, see: https://support.oracle.com/epmos/faces/DocumentDisplay?_afrLoop=392085808201943&id=1957943.1

JavaMail API upgrade has potential SMTP configuration error

Valid from Pega Version 7.1.8

The JavaMail API has been upgraded from 1.4.1 to 1.5.2 in this release. This improvement provides greater compatibility and secure connectivity with leading industry email servers.

During the upgrade process, there is a known issue for some configurations of email servers, including Microsoft Exchange Server, that requires the use of an additional setting. After upgrading to this release, if you experience authentication failures when attempting to send email or test SMTP connectivity, do one of the following:

  • Recommended: Review the Microsoft Exchange email server settings to ensure proper configuration for SMTP authentication. In some cases, the use of port 587 instead of the traditional default SMTP port 25 has been shown to address this issue.
  • Create the following Dynamic System Setting with the value "true," and then restart email listeners:

Owning Ruleset: Pega-IntegrationEngine

Setting Purpose: javamail/NoAuthMechanismsRetry

After any email server configuration or upgrade, it is recommended that email listeners are re-tested without using this Dynamic System Setting.

See About Email Account data instances for information on configuring email account records.

Creating data page unit tests in Internet Explorer 8

Valid from Pega Version 7.1.8

When creating data page unit tests, selecting a parent property does not automatically select the child properties when using Internet Explorer 8.

Page and page list properties to be included in a data page unit test are selected on the Create test screen by selecting a check box next to the property name. Normally, selecting the check box of a parent property automatically selects all subsequent child properties as well. When using Internet Explorer 8, child properties are not automatically selected when the parent property's check box is selected.

The solution requires selecting all of the desired child properties individually. Select the check box next to each child property to include it in the data page unit test.

Schema not found error when importing a Rule-Admin-Product file

Valid from Pega Version 7.1.8

If you import a Rule-Admin-Product file (RAP) file that includes a schema that has a view, grammar parsing changes can mean that the Pega 7 Platform is unable to find the schema.

To enable the Pega 7 Platform to find the schema:

  1. Review the error message that indicates that the schema was not found and identify the following items:
    • The name of the schema that is causing the error
    • The table name in the format: wrong_schema_name.table_name...
    • The DDL that the Pega 7 Platform is trying to apply
  2. Use the table name to identify the correct schema name in your system. This schema is usually your data schema, but might also be an external database.
  3. Download the DDL.
  4. Correct the schema name and save the DDL.
  5. Manually apply the DDL.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us