Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Restricted SMA access

Valid from Pega Version 7.1.5

System Management Application (SMA) remote connections are not supported on JBoss EAP 6.x. This means SMA users may only monitor locally connected systems. Ensure that the "Local JVM Connection..." option is selected when configuring PRPC nodes:

Node description cannot match application server node name

Valid from Pega Version 6.3 SP1

A node's Short Description should not be the same value as the application server node name. If the node's Short Description is changed to be the same value as the application server node name, then the node description is automatically changed back to the original value after a system restart.

High number of busy waits when using Oracle SecureFiles

Valid from Pega Version 7.2.1

You might experience a high number of buffer busy waits when using Oracle SecureFiles for BLOB storage. An Oracle buffer busy wait occurs when a session cannot access a database block in the buffer cache, because another session is either reading the block into the buffer or changing the buffer. As a best practice, use Oracle 11.2.0.4 or later, because earlier versions have more problems with SecureFiles. In addition, to minimize the number of busy waits, set the hidden Oracle parameter _securefiles_concurrency_estimate to 50, and partition the table by using a composite range hash partition that is based on the pxCreateDateTime and pzInskey columns.

For more information, see Troubleshooting: High number of busy waits when using Oracle SecureFiles.

Email approval and instantiation not supported on multitenant systems

Valid from Pega Version 7.2.1

The Enable email approval check box appears on the General tab of an approval step in Case Designer in multitenant systems. It also appears on the Approval shape in Designer Studio. In addition, in Designer Studio, the Settings tab in Case Designer displays the option to configure email instantiation. However, because configuring email listeners is not supported on multitenant systems, you cannot enable email approval or email instantiation.

MBean Javadocs download file

Valid from Pega Version 7.2.1

The Pega 7 Platform MBean Javadocs are no longer provided in the distribution image; however, you can download the MBeanJMXJavadoc.zip file that was previously provided in the distribution image.

You can also use JConsole, which is included with the Java Development Kit (JDK), to obtain MBean information. The JConsole MBean tab provides attributes, operations, notifications, and other information on all the MBeans that are registered with the MBean server.

Extract marker file not created at startup

Valid from Pega Version 7.2.1

The extract marker file (PegaRULES_Extract_Marker.txt) is not created at startup, because the rule utility libraries no longer need it. If you used to use the extract marker file to clear the static content file-based cache, to look up lists, or to control starting activities with web nodes, you can delete the contents of the PegaRULES temporary directory instead.

Upgrade/update fails if PostGIS is applied to PegaRULES or PegaDATA schema

Valid from Pega Version 7.2.1

If you use the PostGIS extension to a PostgreSQL database, upgrading or updating the Pega 7 Platform fails if the extension has been applied to either the PegaRULES or PegaDATA schema. PostGIS can be applied to any other schema.

Upgrades and updates from Pega 7.3 on MSSQL fail with column name mismatch

Valid from Pega Version 7.3

This failure applies only to upgrades and updates from Pega® Platform 7.3 on systems running Microsoft® SQL Server®. In Pega 7.3, the capitalization for the column name pc_work_agile.pzPvStream is incorrect. The correct capitalization is pzPVStream. To prevent upgrade and update failures, before you upgrade or update, run the following command from the Microsoft SQL Server Management Studio (SSMS) to rename the column:

EXEC sp_rename ‘data-schema-name.pc_work_agile.pzPvStream', 'pzPVStream', 'COLUMN'

Reports on pc_work_agile table fail in Pega 7.3 on MSSQL

Valid from Pega Version 7.3

This failure applies only to Pega® Platform 7.3 on systems running Microsoft SQL Server. In Pega 7.3, the capitalization for the column name pc_work_agile.pzPvStream is incorrect. The correct capitalization is pzPVStream. To prevent reporting failures on the pc_work_agile table, run the following command from the Microsoft SQL Server Management Studio (SSMS) to rename the column after you install Pega 7.3:

EXEC sp_rename ‘data-schema-name.pc_work_agile.pzPvStream', 'pzPVStream', 'COLUMN'

Nodes in a cluster do not see each other for Docker, multiple VMs, or multiple NICs setup

Valid from Pega Version 7.3

If a cluster is set up in Docker, or uses separate virtual machines (VMs) or multiple network interfaces, you must set the public address in the prconfig.xml file for each Pega® Platform node to avoid problems with node clustering. Add the <env name=”identification/cluster/public/address” value=”IP address”/> setting to specify the public address that is used by each node.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us