Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Source field not displaying in data transform

Valid from Pega Version 7.1.4

On the Data Transform rule form when using the Update Page action, if the Relation value is updated to “with values from”, the Source field will not be displayed.

(Note that for existing data transforms where the Source field has already been completed, this situation should not occur.)

Workaround

  1. Below is a data transform that has been configured to use Update Page.
    DataTransform1.jpg
  2. If a user were to choose an alternate source by updating the ‘with values from’ Relation value, they would not be prompted to provide a page name in the Source field.
    DataTransform2.jpg
  3. At this point, to be able to enter the Source page value, the user has to save the rule, which results in an error because the source page value is blank. This causes the field to appear.
    DataTransform3.jpg
  4. Once the field has appeared, the Source page value can be provided, and the form can be saved successfully.
    DataTransform4.jpg

Required Oracle optimization parameter

Valid from Pega Version 7.1.3

To optimize performance, set the Oracle parameter optimizer_index_cost_adj to a value between 20 and 25. If this value is not set, the system can run exceedingly slowly, potentially blocking users from login.

Synchronized database and application server settings

Valid from Pega Version 7.1.3

Configure your database and application server to use the same time zone and character encoding to avoid conflicts.

Schema not found error when importing a Rule-Admin-Product file

Valid from Pega Version 7.1.8

If you import a Rule-Admin-Product file (RAP) file that includes a schema that has a view, grammar parsing changes can mean that the Pega 7 Platform is unable to find the schema.

To enable the Pega 7 Platform to find the schema:

  1. Review the error message that indicates that the schema was not found and identify the following items:
    • The name of the schema that is causing the error
    • The table name in the format: wrong_schema_name.table_name...
    • The DDL that the Pega 7 Platform is trying to apply
  2. Use the table name to identify the correct schema name in your system. This schema is usually your data schema, but might also be an external database.
  3. Download the DDL.
  4. Correct the schema name and save the DDL.
  5. Manually apply the DDL.

Node description cannot match application server node name

Valid from Pega Version 6.3 SP1

A node's Short Description should not be the same value as the application server node name. If the node's Short Description is changed to be the same value as the application server node name, then the node description is automatically changed back to the original value after a system restart.

WebSphere log error with Java 8 for Enterprise JavaBeans

Valid from Pega Version 7.1.8

For environments that are deployed by using Java 8 on IBM WebSphere Application Server version 8.5.5.9 through the last 8.5.5.x fix pack, the log might report that a class was not found when the application server attempts to start Enterprise JavaBeans. If Java EE functionality is not needed, no further action is required. However, to use Enterprise JavaBeans, see WebSphere log error with Java 8 for Enterprise JavaBeans.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us