Mobile features deprecated in 8.4

Valid from Pega Version 8.4

Following the introduction of new functionalities for mobile apps, some features are reaching end of life. To avoid additional effort during updates to future releases, do not use deprecated features.

In the 8.4 release, the following features are no longer recommended:

  • Mobile Client 7 is now deprecated and planned for removal in 8.5. Use Pega Infinity Mobile Client to meet the mobile needs of your business.
  • The Reuse existing web portal functionality is deprecated and planned for removal in 8.5. For improved app performance and more efficient development, use the mobile app builder in the mobile channel. Also, you must convert existing projects to use separate channels for mobile and web portals before upgrading to 8.5.

In addition, the Pega Mobile Express app has been removed from app stores and replaced with the Pega Mobile Preview app.

Source field not displaying in data transform

Valid from Pega Version 7.1.4

On the Data Transform rule form when using the Update Page action, if the Relation value is updated to “with values from”, the Source field will not be displayed.

(Note that for existing data transforms where the Source field has already been completed, this situation should not occur.)

Workaround

  1. Below is a data transform that has been configured to use Update Page.
    DataTransform1.jpg
  2. If a user were to choose an alternate source by updating the ‘with values from’ Relation value, they would not be prompted to provide a page name in the Source field.
    DataTransform2.jpg
  3. At this point, to be able to enter the Source page value, the user has to save the rule, which results in an error because the source page value is blank. This causes the field to appear.
    DataTransform3.jpg
  4. Once the field has appeared, the Source page value can be provided, and the form can be saved successfully.
    DataTransform4.jpg

Automated Unit Testing is unavailable

Valid from Pega Version 7.1.1

Automated Unit Testing (AUT) is unavailable in 7.1.1 - 7.1.5.

Starting in 7.1.6, users can access AUT features from supported browser versions of IE.

IE8 limits expansion features

Valid from Pega Version 7.1.1

Internet Explorer 8 (IE8) does not support CSS media queries, which are used by re-expansion features in the Designer Studio. IE8 users with low screen resolution (800 x 600) and a small window size may find that the explorer area in the Designer Studio collapses but cannot re-expand. 

As a work around, access the Designer Studio from another supported browser version and use the recommended, minimum screen resolution width of 1280 pixels.

User interface distortions in the Decision Manager portal

Valid from Pega Version 7.1.6

By default, the New Application wizard in Pega 7.1.6 configures new applications to include UI-Kit-7 in the list of application rulesets. This ruleset causes user interface distortions in the Decision Manager portal. Both applications created in previous maintenance level updates and applications created in Pega 7.1.6 that do not include the UI-Kit-7 dependency are not impacted by this known issue.

Workaround:

  1. Open the application record.
  2. In Application Rulesets, remove UI-Kit-7.
  3. Save the application record.

User interface distortions in the Predictive Analytics Director portal

Valid from Pega Version 7.1.6

By default, the New Application wizard configures new applications to include UI-Kit-7 in the list of application rulesets. This ruleset causes user interface distortions in the Predictive Analytics Director portal. Applications created in maintenance level updates previous to Pega 7.1.6, and applications that do not include the UI-Kit-7 dependency, are not impacted by this known issue.

Workaround:

  1. Open the application record.
  2. In Application Rulesets, remove UI-Kit-7.
  3. Save the application record.

Email approval and instantiation not supported on multitenant systems

Valid from Pega Version 7.2.1

The Enable email approval check box appears on the General tab of an approval step in Case Designer in multitenant systems. It also appears on the Approval shape in Designer Studio. In addition, in Designer Studio, the Settings tab in Case Designer displays the option to configure email instantiation. However, because configuring email listeners is not supported on multitenant systems, you cannot enable email approval or email instantiation.

MBean Javadocs download file

Valid from Pega Version 7.2.1

The Pega 7 Platform MBean Javadocs are no longer provided in the distribution image; however, you can download the MBeanJMXJavadoc.zip file that was previously provided in the distribution image.

You can also use JConsole, which is included with the Java Development Kit (JDK), to obtain MBean information. The JConsole MBean tab provides attributes, operations, notifications, and other information on all the MBeans that are registered with the MBean server.

Cannot send mobile push notifications when the Pega 7 Platform is hosted on WebSphere Application Server

Valid from Pega Version 7.2.1

Push notifications are not sent to Android or iOS mobile apps when the Pega 7 Platform is hosted on WebSphere Application Server.