Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

DB2-LUW database logfile size increase

Valid from Pega Version 7.1.5

This issue applies to DB2-LUW database platforms only.
 

To avoid running out of logfile space due to large transaction sets during the rule base load of a Pega 7.1.x install, upgrade, or maintenance level update, systems supported by a DB2-LUW database platform should increase the LOGFILSIZ parameter to at least 4096 pages from the default size of 1000 pages.

After the size has been increased, restart the database to ensure that the new setting is loaded into the database correctly.

Need to run script before updating Multitenant systems

Valid from Pega Version 7.1.5

When updating or upgrading a Multitenant system from Pega 7.1.5 or 7.1.6 to Pega 7.1.7, if that system uses either an Oracle or a PostgreSQL database, you may encounter the error:

“Table must be empty to add column.”

The Multitenant architecture requires an additional column on a number of the PRPC database tables (“pzTenantID”). In Pega 7.1.7, two additional PRPC tables were tenant-qualified: pc_schedule_task and pr_index_schedule_task. The Multitenant column is added to these tables by the update/upgrade process. However, Oracle and PostgreSQL do not allow the addition of a non-null column to an existing table unless the table is empty, so updating or upgrading systems on those databases displays the error detailed above.

To avoid this error, before beginning the update or upgrade, it is necessary to run a script:

  • OracleOracleMTupgrade.sql
  • PostgreSQLPostgresMTupgrade.sql

For updates, these scripts are located in the /scripts/ddl directory.

For upgrades, these scripts are located in the /Resourcekit/AdditionalUpgradeScripts directory.

Add additional columns to customized work history tables

Valid from Pega Version 7.1.6

The standard work history table, pc_history_work, contains two new columns that return the latitude and longitude coordinate location of the action that prompted the history. Mobile devices can display this location as a street address. If you have a customized work history table, add these two columns to it:

  • <decimal name="pxLatitude" size="19" scale="9"/>
  • <decimal name="pxLongitude" size="19" scale="9"/>

Existing operator IDs during upgrades and updates

Valid from Pega Version 7.2.2

Upgrades and updates are always performed in secured mode to help prevent unauthorized access to your system. In secured mode, the [email protected] operator ID is always overwritten, but other existing standard operator IDs are not modified. New operator IDs are inserted in secured mode. For more information, see the Deployment Guide for your environment.

No longer supported translator configuration options

Valid from Pega Version 7.4

The following translator configuration options are not needed and are no longer supported. If you previously configured any of these system settings, remove them from the system settings to avoid a warning message. For example, if you set translator/useparserfamily, the following message is displayed at startup: "Translator option, 'translator/useparserfamily' is not needed and no longer supported. Remove this from the system settings."

  • translator/useparserfamily
  • translator/usecodegenerator
  • translator/usenativedouble
  • translator/optimization/use71BlockAnalysis
  • translator/optimization/use71ConstantFolding
  • translator/optimization/use71AssignmentTypeSimplification
  • translator/optimization/use71IntrinsicFunctions
  • translator/use71PropSetGeneration
  • translator/use71ParserAssignment
  • assembly/model/useBlock4ContiguousSets
  • /translator/pandc/comparepandcalgorithms
  • /translator/pandc/use6xalgorithms
  • /Compatibility/CheckForTopLevelClassMismatch

In addition, the com.pega.pegarules.generation.parseoverride bootstrap option is no longer supported. Remove this option from the system settings.

New privilege required to access the Search landing page

Valid from Pega Version 7.4

After upgrading to Pega® Platform 7.4, users who do not have the pxAccessSearchLP privilege cannot access the Search landing page. The pxAccessSearchLP privilege is automatically assigned to the SysAdm4 role. If you have other roles that require access to the Search landing page, you must add the pxAccessSearchLP privilege to those roles.

For more information about assigning privileges to roles, see User privilege authorization. (Link to: basics/v6portal/landingpages/accessmanager/customizeprivilegestab.htm)

PegaDATA connection settings now required in the prconfig.xml file

Valid from Pega Version 7.4

If you use the default prconfig.xml file that is included with Pega® Platform, and you have not removed the PegaDATA connection settings, no action is required. If you use a custom prconfig.xml file, for example, for running tests, ensure that the database connection settings for PegaDATA are not blank.

For more information about the connection settings, see PegaDATA connection settings in the prconfig.xml file.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us