JavaMail API upgrade has potential SMTP configuration error
Valid from Pega Version 7.1.8
The JavaMail API has been upgraded from 1.4.1 to 1.5.2 in this release. This improvement provides greater compatibility and secure connectivity with leading industry email servers.
During the upgrade process, there is a known issue for some configurations of email servers, including Microsoft Exchange Server, that requires the use of an additional setting. After upgrading to this release, if you experience authentication failures when attempting to send email or test SMTP connectivity, do one of the following:
- Recommended: Review the Microsoft Exchange email server settings to ensure proper configuration for SMTP authentication. In some cases, the use of port 587 instead of the traditional default SMTP port 25 has been shown to address this issue.
- Create the following Dynamic System Setting with the value "true," and then restart email listeners:
Owning Ruleset: Pega-IntegrationEngine
Setting Purpose: javamail/NoAuthMechanismsRetry
After any email server configuration or upgrade, it is recommended that email listeners are re-tested without using this Dynamic System Setting.
See About Email Account data instances for information on configuring email account records.
Number and text input controls on Android devices may not display the correct keyboard
Valid from Pega Version 7.1.8
When running a Pega 7 application on a device using the Android operating system, pxNumber and pxTextInput controls may not display when using the desired on-screen keyboard. This happens when the number or text input type is set to number
.
At design time, the input type is selected in the Editable Format section of the Presentation tab in the Cell Properties panel for a pxNumber or pxTextInput control. Due to a known limitation in some versions of the Android OS running on some devices, the keyboard displayed at run time may not support entry of decimal values when a Number type keyboard is specified.
To resolve this issue, use the Phone
type when numbers with decimal values may be required. Using the Phone
type displays a numerical phone keyboard. The Android phone keyboard includes both commas and periods so that decimals may be entered.
The Phone type selected in the Presentation tab of a Number control
Note that this issue only occurs on Android devices. It is recommended that applications for iOS continue to use type=“Number”.
Decision Data Store data sets can be used only on DNodes
Valid from Pega Version 7.1.8
Data flows that contain Decision Data Store data sets as the primary or secondary source must be created and executed only on DNodes.
Data flows are not restarted automatically after application server restart
Valid from Pega Version 7.1.8
When you restart the application server or the Pega 7 server, you stop the execution of your data flows. The interrupted batch and real-time runs are marked as Failed.
Recommendation:
- Go to the > > > > tab and start the failed batch runs.
-
Go to the
> > > > tab and activate the failed real-time runs.
Value list and value group properties are not supported inside data flows
Valid from Pega Version 7.1.8
Value list and value group properties are not supported inside data flows, and you need to instead use other property types.
See the Pega 7 developer help to check all available property types.
Data flow preview size is fixed to 10
Valid from Pega Version 7.1.8
The Preview option for each shape in data flows returns the first 10 records. This value is fixed and currently cannot be changed.
Data Flow transformation shapes cannot be used in combination with the Compose or Merge shapes
Valid from Pega Version 7.1.8
When you reference another data flow from a data flow that contains the Compose or shape, the referenced data flow cannot contain transformation shapes ( , , ).
Data flow validation does not currently prevent you from designing a data flow that goes against this design pattern. Make sure that your data flows follow this design pattern by checking the referenced and referencing data flows.
Data flow destination is resolved at assembly time
Valid from Pega Version 7.1.8
Data flow execution always uses the design-time destination data sets or destination data flows, regardless of the input records at run time.
Example:
You create a data flow and set the destination to a specific data set. In the data flow, you use a strategy that produces some results. Regardless of these results, the execution of your data flow always uses the destination data set that you specified when you designed the data flow.
The same applies when you set the destination to a data flow.
Creating data page unit tests in Internet Explorer 8
Valid from Pega Version 7.1.8
When creating data page unit tests, selecting a parent property does not automatically select the child properties when using Internet Explorer 8.
Page and page list properties to be included in a data page unit test are selected on the Create test screen by selecting a check box next to the property name. Normally, selecting the check box of a parent property automatically selects all subsequent child properties as well. When using Internet Explorer 8, child properties are not automatically selected when the parent property's check box is selected.
The solution requires selecting all of the desired child properties individually. Select the check box next to each child property to include it in the data page unit test.
Schema not found error when importing a Rule-Admin-Product file
Valid from Pega Version 7.1.8
If you import a Rule-Admin-Product file (RAP) file that includes a schema that has a view, grammar parsing changes can mean that the Pega 7 Platform is unable to find the schema.
To enable the Pega 7 Platform to find the schema:
- Review the error message that indicates that the schema was not found and identify the following items:
- The name of the schema that is causing the error
- The table name in the format: wrong_schema_name.table_name...
- The DDL that the Pega 7 Platform is trying to apply
- Use the table name to identify the correct schema name in your system. This schema is usually your data schema, but might also be an external database.
- Download the DDL.
- Correct the schema name and save the DDL.
- Manually apply the DDL.