Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Restricted SMA access

Valid from Pega Version 7.1.5

System Management Application (SMA) remote connections are not supported on JBoss EAP 6.x. This means SMA users may only monitor locally connected systems. Ensure that the "Local JVM Connection..." option is selected when configuring PRPC nodes:

Text Input control number type does not validate

Valid from Pega Version 7.1.5

When a Text Input control type is set to "Number" in the Presentation tab:

  • Validation does not trigger and the field is blanked out when a user submits the form.
  • If a value other than a number is entered, the browser sends an empty value, and the value is not validated.
  • In the Clipboard, the field value displays as empty.
  • If the field is required, the validation displays.

This issue occurs when using both the Chrome and Safari web browsers, and is a result of browser behavior for the HTML5 type=“number”. To fix this issue when using these browsers, do not use the "Number" type in Presentation tab of a Text Input control. Instead, the type should be set to "Text".

Unclear error message when saving shared class instance in tenant layer

Valid from Pega Version 7.1.5

If you attempt to save a shared class instance from the tenant layer, Pega 7 displays this message:

This record has x errors. Save Failed: There was a problem saving an instance of class: Error Code: <none> SQL State: <none> Message: <none>

You cannot save a shared instance from the tenant layer if that instance cannot be overridden.

Number and text input controls on Android devices may not display the correct keyboard

Valid from Pega Version 7.1.8

When running a Pega 7 application on a device using the Android operating system, pxNumber and pxTextInput controls may not display when using the desired on-screen keyboard. This happens when the number or text input type is set to number.

At design time, the input type is selected in the Editable Format section of the Presentation tab in the Cell Properties panel for a pxNumber or pxTextInput control. Due to a known limitation in some versions of the Android OS running on some devices, the keyboard displayed at run time may not support entry of decimal values when a Number type keyboard is specified.

To resolve this issue, use the Phone type when numbers with decimal values may be required. Using the Phone type displays a numerical phone keyboard. The Android phone keyboard includes both commas and periods so that decimals may be entered.

Cell Properties dialog

The Phone type selected in the Presentation tab of a Number control

Note that this issue only occurs on Android devices. It is recommended that applications for iOS continue to use type=“Number”.

The Create Build button appears grayed out when configuring and building a mobile application

Valid from Pega Version 7.1.8

When you attempt to configure and build your Android or iOS mobile application from the Mobile tab, the Create build button might appear dimmed. This issue occurs if any of the access roles in the access group were cloned from the PegaRULES:SysAdm4 access role.

Refer to Troubleshooting Pega Mobile Client to learn how to fix this issue in your application.

Decision Data Store data sets can be used only on DNodes

Valid from Pega Version 7.1.8

Data flows that contain Decision Data Store data sets as the primary or secondary source must be created and executed only on DNodes.

Data flows are not restarted automatically after application server restart

Valid from Pega Version 7.1.8

When you restart the application server or the Pega 7 server, you stop the execution of your data flows. The interrupted batch and real-time runs are marked as Failed

Recommendation:

  • Go to the Designer StudioDecisioning > Decisions > Data Flows > Batch processing tab and start the failed batch runs.
  • Go to the Designer StudioDecisioning > Decisions > Data Flows > Real-time processing tab and activate the failed real-time runs.

 

Value list and value group properties are not supported inside data flows

Valid from Pega Version 7.1.8

Value list and value group properties are not supported inside data flows, and you need to instead use other property types.

See the Pega 7 developer help to check all available property types.

Data flow preview size is fixed to 10

Valid from Pega Version 7.1.8

The Preview option for each shape in data flows returns the first 10 records. This value is fixed and currently cannot be changed.

Data Flow transformation shapes cannot be used in combination with the Compose or Merge shapes

Valid from Pega Version 7.1.8

When you reference another data flow from a data flow that contains the Compose or Merge shape, the referenced data flow cannot contain transformation shapes (EventStrategy, Decision strategy, Convert).

Data flow validation does not currently prevent you from designing a data flow that goes against this design pattern. Make sure that your data flows follow this design pattern by checking the referenced and referencing data flows.

 

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us