Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Required Oracle optimization parameter

Valid from Pega Version 7.1.3

To optimize performance, set the Oracle parameter optimizer_index_cost_adj to a value between 20 and 25. If this value is not set, the system can run exceedingly slowly, potentially blocking users from login.

Slow WebSphere performance on Mac platforms

Valid from Pega Version 7.1.2

Use the following JVM setting to improve WebSphere performance on Mac platforms:

-Djava.net.preferIPv4Stack=true

Synchronized database and application server settings

Valid from Pega Version 7.1.3

Configure your database and application server to use the same time zone and character encoding to avoid conflicts.

Cannot copy final section rules in UI Kit ruleset

Valid from Pega Version 7.1.6

You cannot copy section rules in the UI Kit ruleset (UI-Kit-71) that start with pz or px (final rules in the base PRPC rulesets).

Instead, to customize these rules, use the Copy/Merge Ruleset tool, available at Designer Studio >System > Tools > Refactor Rulesets, to copy all rules from the UI Kit into your application ruleset. You can then check the section rules in and out.

User interface distortions in the Decision Manager portal

Valid from Pega Version 7.1.6

By default, the New Application wizard in Pega 7.1.6 configures new applications to include UI-Kit-7 in the list of application rulesets. This ruleset causes user interface distortions in the Decision Manager portal. Both applications created in previous maintenance level updates and applications created in Pega 7.1.6 that do not include the UI-Kit-7 dependency are not impacted by this known issue.

Workaround:

  1. Open the application record.
  2. In Application Rulesets, remove UI-Kit-7.
  3. Save the application record.

User interface distortions in the Predictive Analytics Director portal

Valid from Pega Version 7.1.6

By default, the New Application wizard configures new applications to include UI-Kit-7 in the list of application rulesets. This ruleset causes user interface distortions in the Predictive Analytics Director portal. Applications created in maintenance level updates previous to Pega 7.1.6, and applications that do not include the UI-Kit-7 dependency, are not impacted by this known issue.

Workaround:

  1. Open the application record.
  2. In Application Rulesets, remove UI-Kit-7.
  3. Save the application record.

Microsof Internet Explorer 9 (IE9) may display a script error when clicking a Help button

Valid from Pega Version 7.1.6

A script error may be displayed when clicking a Help button when script error notification is turned on in the browser. As a work around, uncheck the Display a notification about every script error option in the Advanced tab of the Options dialog box in Microsoft Internet Explorer 9.

High number of busy waits when using Oracle SecureFiles

Valid from Pega Version 7.2.1

You might experience a high number of buffer busy waits when using Oracle SecureFiles for BLOB storage. An Oracle buffer busy wait occurs when a session cannot access a database block in the buffer cache, because another session is either reading the block into the buffer or changing the buffer. As a best practice, use Oracle 11.2.0.4 or later, because earlier versions have more problems with SecureFiles. In addition, to minimize the number of busy waits, set the hidden Oracle parameter _securefiles_concurrency_estimate to 50, and partition the table by using a composite range hash partition that is based on the pxCreateDateTime and pzInskey columns.

For more information, see Troubleshooting: High number of busy waits when using Oracle SecureFiles.

Ignore locale settings requires refresh after server restarts

Valid from Pega Version 7.2.1

The Ignore locale check box in operator preferences is selected to display Designer Studio in U.S. English. After a server restarts, screens initially ignore this setting. When the screen is refreshed or reopened, the screen is rendered as expected.

Flexbox-based dynamic layouts not supported for Android 4.4 and earlier

Valid from Pega Version 7.2.1

Flexbox-based dynamic layouts are not supported in Android 4.4 and earlier. When developing applications to be used on devices running Android 4.4 and earlier, use the inline-block layout mode for dynamic layouts.