Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Required Oracle optimization parameter

Valid from Pega Version 7.1.3

To optimize performance, set the Oracle parameter optimizer_index_cost_adj to a value between 20 and 25. If this value is not set, the system can run exceedingly slowly, potentially blocking users from login.

Synchronized database and application server settings

Valid from Pega Version 7.1.3

Configure your database and application server to use the same time zone and character encoding to avoid conflicts.

Cannot copy final section rules in UI Kit ruleset

Valid from Pega Version 7.1.6

You cannot copy section rules in the UI Kit ruleset (UI-Kit-71) that start with pz or px (final rules in the base PRPC rulesets).

Instead, to customize these rules, use the Copy/Merge Ruleset tool, available at Designer Studio >System > Tools > Refactor Rulesets, to copy all rules from the UI Kit into your application ruleset. You can then check the section rules in and out.

User interface distortions in the Decision Manager portal

Valid from Pega Version 7.1.6

By default, the New Application wizard in Pega 7.1.6 configures new applications to include UI-Kit-7 in the list of application rulesets. This ruleset causes user interface distortions in the Decision Manager portal. Both applications created in previous maintenance level updates and applications created in Pega 7.1.6 that do not include the UI-Kit-7 dependency are not impacted by this known issue.

Workaround:

  1. Open the application record.
  2. In Application Rulesets, remove UI-Kit-7.
  3. Save the application record.

Use JDBC 4 compliant drivers for better performance

Valid from Pega Version 7.1.7

For better performance, ensure that you are using JDBC 4-compliant drivers.  For more information on supported and non-supported JDBC drivers, please reference the Platform Support Guide.

Use Tomcat 7 for better performance

Valid from Pega Version 7.1.7

For better performance with a Tomcat web server, use Tomcat 7.

Tomcat 6 has a limitation that causes the server to treat the JDBC driver as if it were a JDBC 3-compliant driver, even if the system is using a JDBC 4-compliant driver. Customers using Tomcat will see better performance if they upgrade to Tomcat 7 and use a JDBC 4-compliant driver.

Engine will not start if the incorrect JDBC driver is used

Valid from Pega Version 7.1.7

The engine will not start up if the incorrect JDBC driver is used. The following configurations are unsupported:

  • Using a Multi-tenant Oracle system with one of the Oracle JDBC drivers with issues (see the chart in the Platform Support Guide)
  • Using a Multi-tenant system with a JDBC 3 compliant driver, OR with Tomcat 6 (for more information on using tomcat with Pega 7.1.7, see Use Tomcat 7 for best performance)
  • Using Microsoft SQL Server with a JDBC 3 compliant driver, OR with Tomcat 6 (for more information on using tomcat with Pega 7.1.7, see Use Tomcat 7 for best performance)

When any of these unsupported configurations are encountered, Pega 7 will not start. Before this change, the engine would appear to start up properly, but would encounter issues during other parts of the engine startup or during actual use of the system.

User interface distortions in the Predictive Analytics Director portal

Valid from Pega Version 7.1.6

By default, the New Application wizard configures new applications to include UI-Kit-7 in the list of application rulesets. This ruleset causes user interface distortions in the Predictive Analytics Director portal. Applications created in maintenance level updates previous to Pega 7.1.6, and applications that do not include the UI-Kit-7 dependency, are not impacted by this known issue.

Workaround:

  1. Open the application record.
  2. In Application Rulesets, remove UI-Kit-7.
  3. Save the application record.

Noticeable differences between work objects created in the Decision Manager portal when compared to Designer Studio

Valid from Pega Version 7.1.7

In the Decision Manager portal, you create work objects by running flows in the enterprise application that serves as the base application for the application overlay. If the enterprise application does not include the UI-Kit-7 in its application rulesets, work objects can display differently in the Decision Manager portal when compared to Designer Studio because an application overlay is always configured to include the UI-Kit-7 ruleset.

Recommendation:

  1. Add the UI-Kit-7 ruleset dependency to the enterprise application.
  2. Redesign the user interface to comply with the UI-Kit-7 ruleset.

IBM WebSphere Application Server V8: Edit the URL for Enabling System Management Application

Valid from Pega Version 7.1.7

WebSphere 8 does not correctly resolve the URL to enable System Management Application. As a workaround, when you configure the application server, you can do either of these actions:

  • Enter the full URL in the format:
    ​http://hostname:port/prsysmgmt/getnodes.action

  • Set the com.ibm.ws.webcontainer.redirectcontextroot property to true.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us