Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Required Oracle optimization parameter

Valid from Pega Version 7.1.3

To optimize performance, set the Oracle parameter optimizer_index_cost_adj to a value between 20 and 25. If this value is not set, the system can run exceedingly slowly, potentially blocking users from login.

Slow WebSphere performance on Mac platforms

Valid from Pega Version 7.1.2

Use the following JVM setting to improve WebSphere performance on Mac platforms:

-Djava.net.preferIPv4Stack=true

Synchronized database and application server settings

Valid from Pega Version 7.1.3

Configure your database and application server to use the same time zone and character encoding to avoid conflicts.

Restricted SMA access

Valid from Pega Version 7.1.5

System Management Application (SMA) remote connections are not supported on JBoss EAP 6.x. This means SMA users may only monitor locally connected systems. Ensure that the "Local JVM Connection..." option is selected when configuring PRPC nodes:

Cannot copy final section rules in UI Kit ruleset

Valid from Pega Version 7.1.6

You cannot copy section rules in the UI Kit ruleset (UI-Kit-71) that start with pz or px (final rules in the base PRPC rulesets).

Instead, to customize these rules, use the Copy/Merge Ruleset tool, available at Designer Studio >System > Tools > Refactor Rulesets, to copy all rules from the UI Kit into your application ruleset. You can then check the section rules in and out.

User interface distortions in the Decision Manager portal

Valid from Pega Version 7.1.6

By default, the New Application wizard in Pega 7.1.6 configures new applications to include UI-Kit-7 in the list of application rulesets. This ruleset causes user interface distortions in the Decision Manager portal. Both applications created in previous maintenance level updates and applications created in Pega 7.1.6 that do not include the UI-Kit-7 dependency are not impacted by this known issue.

Workaround:

  1. Open the application record.
  2. In Application Rulesets, remove UI-Kit-7.
  3. Save the application record.

Text Input control number type does not validate

Valid from Pega Version 7.1.5

When a Text Input control type is set to "Number" in the Presentation tab:

  • Validation does not trigger and the field is blanked out when a user submits the form.
  • If a value other than a number is entered, the browser sends an empty value, and the value is not validated.
  • In the Clipboard, the field value displays as empty.
  • If the field is required, the validation displays.

This issue occurs when using both the Chrome and Safari web browsers, and is a result of browser behavior for the HTML5 type=“number”. To fix this issue when using these browsers, do not use the "Number" type in Presentation tab of a Text Input control. Instead, the type should be set to "Text".

User interface distortions in the Predictive Analytics Director portal

Valid from Pega Version 7.1.6

By default, the New Application wizard configures new applications to include UI-Kit-7 in the list of application rulesets. This ruleset causes user interface distortions in the Predictive Analytics Director portal. Applications created in maintenance level updates previous to Pega 7.1.6, and applications that do not include the UI-Kit-7 dependency, are not impacted by this known issue.

Workaround:

  1. Open the application record.
  2. In Application Rulesets, remove UI-Kit-7.
  3. Save the application record.

Unclear error message when saving shared class instance in tenant layer

Valid from Pega Version 7.1.5

If you attempt to save a shared class instance from the tenant layer, Pega 7 displays this message:

This record has x errors. Save Failed: There was a problem saving an instance of class: Error Code: <none> SQL State: <none> Message: <none>

You cannot save a shared instance from the tenant layer if that instance cannot be overridden.

Microsof Internet Explorer 9 (IE9) may display a script error when clicking a Help button

Valid from Pega Version 7.1.6

A script error may be displayed when clicking a Help button when script error notification is turned on in the browser. As a work around, uncheck the Display a notification about every script error option in the Advanced tab of the Options dialog box in Microsoft Internet Explorer 9.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us