Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Required Oracle optimization parameter

Valid from Pega Version 7.1.3

To optimize performance, set the Oracle parameter optimizer_index_cost_adj to a value between 20 and 25. If this value is not set, the system can run exceedingly slowly, potentially blocking users from login.

Synchronized database and application server settings

Valid from Pega Version 7.1.3

Configure your database and application server to use the same time zone and character encoding to avoid conflicts.

Geolocation tracking requires browser permission

Valid from Pega Version 7.1.6

When the geolocation tracking feature is enabled, a Map it link appears next to each requestor entry in the audit trail. When you click a link for the first time, the browser displays a notification asking whether you want to permit tracking. Make your yes/no selection in the prompt. Do not click "X" to close it, as doing so may render the session unresponsive. Refresh the browser if necessary and make your selection.

Geolocation tracking Map it links do not appear

Valid from Pega Version 7.1.6

If geolocation tracking is enabled, the first time you create a case in the first browser session, the Map it links do not appear next to the initial audit trail entries. When you submit the first flow action, the links appear next to all subsequent entries.

Primary key constraint error when using JBoss

Valid from Pega Version 7.1.9

A primary key constraint violation exception might occur in the following situation: you use JBoss EAP 6.4 and SQL Server 2012 with a JDBC 4 driver, and you use two or more file listeners or JMS MDB listeners with concurrent threads that create work objects that use multiple files. If a primary key constraint violation exception occurs in this situation, update the data source configuration file to set the jta parameter to true. For example, set <datasource jta="true" jndi-name-"java:/jdbc/PegaRULES>.

Multiple notifications are delivered for the same Pulse post

Valid from Pega Version 7.3

When a user posts a Pulse comment, the users who subscribe to the activity feed might receive more than one notification if the posted comment triggers several notification rules.

For example, when a user posts a comment on a case that he or she follows, any response to the comment can result in the following notifications:

  • Notification when a new comment is posted on the followed case (triggers the pyAddPulsePost notification definition)
  • Notification when a comment is a response to the user’s original post (triggers the pyAddPulsePost notification definition)
  • Notification when the user is mentioned in the comment (triggers the pyAddUserMentionedPost notification definition)

Surveys are not compatible with prior versions of the UI Kit

Valid from Pega Version 7.3

Now that survey functionality is available in the Pega-Survey ruleset, some rules are no longer compatible with prior versions of the UI Kit. To ensure that your surveys are rendered correctly, update your Application form to include version 09.01 of the UI Kit.

If you cannot change the version of the UI Kit, you can override the Work-.pyCaseActionArea section in your application and update it to use the same configuration as the section in version 09.01 of the UI Kit.

Surveys do not display navigation links

Valid from Pega Version 7.3

The navigation links, or bread crumbs, in a survey are not displayed when you configure a survey to run as a screen flow. To resolve this issue, override the Work-.pyCaseActionArea section in your application, and then update that section to include the Work-.ProcessSteps_ScreenFlow section.

Surveys do not display questions with custom templates

Valid from Pega Version 7.3

Because many rules have been refactored or renamed in the Pega-Survey ruleset, questions that use custom templates are not displayed in surveys. To resolve this issue, create a new version of the applicable sections from the Embed-PegaQ-Results-Question class in your application, and then update the sections to include your custom content and logic.

Upgrades and updates from Pega 7.3 on MSSQL fail with column name mismatch

Valid from Pega Version 7.3

This failure applies only to upgrades and updates from Pega® Platform 7.3 on systems running Microsoft® SQL Server®. In Pega 7.3, the capitalization for the column name pc_work_agile.pzPvStream is incorrect. The correct capitalization is pzPVStream. To prevent upgrade and update failures, before you upgrade or update, run the following command from the Microsoft SQL Server Management Studio (SSMS) to rename the column:

EXEC sp_rename ‘data-schema-name.pc_work_agile.pzPvStream', 'pzPVStream', 'COLUMN'

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us