Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

WSDL generation error prevents invocation of SOAP services

Valid from Pega Version 8.4.2

Status

A Known Issue was introduced in the 8.4.2 Pega Platform patch release, which impacts both upgrades and new installations of that version.

Description

Due to changes introduced in the SOAP functionality for the case-mismatch error in SR-D98509/INC-119725, the WSDL is being generated for SOAP services with an incorrectly-capitalized element, which prevents the service from being invoked.  The element should be “name” instead of “Name”.

Workaround

Clients must perform the following workaround after they define a new SOAP connector in Pega Platform:

  1. To download the WSDL from Pega Platform:
    1. After using the SOAP Wizard (Dev Studio > Configure > Integration > Services > Service Wizard) the WSDL URL is shown at the bottom right of the Dev Studio screen.
    2. Click the URL to display the XML.
    3. Save the WSDL file to your local system.
  2. In the text editor of your choice, modify "Name" to "name" in every <element “name” = … > tag in the WDSL.
  3. Save your changes to the local file.
  4. To reload the WSDL into Pega Platform:
    1. In Dev Studio, open the Configure menu.
    2. Select Integration > Connectors > Create SOAP Integration.
    3. In the New SOAP integration wizard, select Upload WSDL from File.
    4. Complete the upload using the wizard prompts.

This is a design-time issue, not a run-time issue; therefore, clients only have to perform this workaround process once. Existing SOAP services should not be impacted; however, if clients modify an existing SOAP service definition by re-running the wizard, clients must reapply the workaround for Pega Platform to recognize the SOAP definition changes.  

Resolution

This issue will be addressed in the Pega Platform Patch Release 8.4.3.  Clients who upgrade to that version or later should not see this issue.

Required Oracle optimization parameter

Valid from Pega Version 7.1.3

To optimize performance, set the Oracle parameter optimizer_index_cost_adj to a value between 20 and 25. If this value is not set, the system can run exceedingly slowly, potentially blocking users from login.

Synchronized database and application server settings

Valid from Pega Version 7.1.3

Configure your database and application server to use the same time zone and character encoding to avoid conflicts.

Node description cannot match application server node name

Valid from Pega Version 6.3 SP1

A node's Short Description should not be the same value as the application server node name. If the node's Short Description is changed to be the same value as the application server node name, then the node description is automatically changed back to the original value after a system restart.

Multiple notifications are delivered for the same Pulse post

Valid from Pega Version 7.3

When a user posts a Pulse comment, the users who subscribe to the activity feed might receive more than one notification if the posted comment triggers several notification rules.

For example, when a user posts a comment on a case that he or she follows, any response to the comment can result in the following notifications:

  • Notification when a new comment is posted on the followed case (triggers the pyAddPulsePost notification definition)
  • Notification when a comment is a response to the user’s original post (triggers the pyAddPulsePost notification definition)
  • Notification when the user is mentioned in the comment (triggers the pyAddUserMentionedPost notification definition)

Surveys are not compatible with prior versions of the UI Kit

Valid from Pega Version 7.3

Now that survey functionality is available in the Pega-Survey ruleset, some rules are no longer compatible with prior versions of the UI Kit. To ensure that your surveys are rendered correctly, update your Application form to include version 09.01 of the UI Kit.

If you cannot change the version of the UI Kit, you can override the Work-.pyCaseActionArea section in your application and update it to use the same configuration as the section in version 09.01 of the UI Kit.

Surveys do not display navigation links

Valid from Pega Version 7.3

The navigation links, or bread crumbs, in a survey are not displayed when you configure a survey to run as a screen flow. To resolve this issue, override the Work-.pyCaseActionArea section in your application, and then update that section to include the Work-.ProcessSteps_ScreenFlow section.

Surveys do not display questions with custom templates

Valid from Pega Version 7.3

Because many rules have been refactored or renamed in the Pega-Survey ruleset, questions that use custom templates are not displayed in surveys. To resolve this issue, create a new version of the applicable sections from the Embed-PegaQ-Results-Question class in your application, and then update the sections to include your custom content and logic.

Upgrades and updates from Pega 7.3 on MSSQL fail with column name mismatch

Valid from Pega Version 7.3

This failure applies only to upgrades and updates from Pega® Platform 7.3 on systems running Microsoft® SQL Server®. In Pega 7.3, the capitalization for the column name pc_work_agile.pzPvStream is incorrect. The correct capitalization is pzPVStream. To prevent upgrade and update failures, before you upgrade or update, run the following command from the Microsoft SQL Server Management Studio (SSMS) to rename the column:

EXEC sp_rename ‘data-schema-name.pc_work_agile.pzPvStream', 'pzPVStream', 'COLUMN'

Reports on pc_work_agile table fail in Pega 7.3 on MSSQL

Valid from Pega Version 7.3

This failure applies only to Pega® Platform 7.3 on systems running Microsoft SQL Server. In Pega 7.3, the capitalization for the column name pc_work_agile.pzPvStream is incorrect. The correct capitalization is pzPVStream. To prevent reporting failures on the pc_work_agile table, run the following command from the Microsoft SQL Server Management Studio (SSMS) to rename the column after you install Pega 7.3:

EXEC sp_rename ‘data-schema-name.pc_work_agile.pzPvStream', 'pzPVStream', 'COLUMN'

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us