Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Word merge support with Microsoft Silverlight plug-in

Valid from Pega Version 7.1.3

PRPC features that integrate with the Word merge capability are now cross-browser. ActiveX controls (which are only compatible with IE) have been replaced with Microsoft Silverlight. This plug-in must be downloaded separately from Microsoft, as it is not shipped with PRPC.

Some common PRPC features affected by this change include the Application Document Wizard, App Profile, Specifications Landing Page, Specification form, and Case Type Landing Page.

Prior to using these features, Users of PRPC 7.1.3 need to set up their client system(s) as follows:

1. Install Silverlight plug-in

Follow the PRPC prompt to install Silverlight when you attempt to use the Word merge feature:

Silverlight1.jpg

Or download package directly: www.microsoft.com/silverlight/

2. Install PRPC prerequisites

Microsoft Internet Explorer (IE) browsers automatically detect the need for PRPC prerequisites and will prompt for install:

Silverlight2.jpg

Non-IE browsers will load a pop-up window when the user attempts to use the Word merge feature.  Use the link to manually download PRPC prerequisites:

Silverlight3.jpg

Extract the .zip file, execute setup.exe and follow the install wizard:

Silverlight4.jpg

Administrators setting up multiple clients at once may refer to the pzSLpreReqs.cab available in the PRPC 7.1.3 resource kit.

3. Restart browser

Log out of PRPC, close all open sessions and restart your browser.

The PRPC feature integrated with Word merge is now ready for use; Silverlight prompts are no longer displayed.

4. Troubleshooting

Silverlight installation requires access to your file system and a registry setting update to “trust” the associated Verisign certificate.  Contact your administrator if you encounter any security or permission errors during this process.

While Silverlight is cross-browser, it is not fully cross-platform.  Mac users may use Word merge features in Chrome via Parallels.

See the PRPC Developer Help for more information on browser setup requirements.

Tomcat log files moved to work directory

Valid from Pega Version 7.1.2

For Tomcat application server users, the default path for PRPC logs has been changed to the "work" directory for Catalina. For example:

<tomcat>\work\Catalina\localhost\prweb

This directory can be cleaned up during administration. To avoid loss of files, you can redirect logging to a different directory after installation:

  1. Navigate to the <tomcat-home>\webapps\prweb\WEB-INF\classes directory.
  2. Open the prlogging.xml file.
  3. Locate the "appender" definitions section that contains the "@{web.tmpdir}" string
  4. Update the FileNamePattern values to point to the new directory.

For more details, refer to the “Change the default path to PRPC logs” section in the Tomcat installation guide for your database.

Data Management

Valid from Pega Version 7.1.3

Improvements to data handling were made for the Data Pages, autopopulate properties, and reference properties.  Lightweight lists were optimized.

  • Property references are now maintained on the Work Page.
  • PageList properties can reference a Data Page.
  • Auto-populate properties can be used in a seciton to show results from a Data Page.
  • Data Pages can run in “Page” mode as well as “List” mode
  • The "Rules Not Using Lightweight List" report was enhanced.
  • A PageList property that references a Data Page may be used to populate a grid.
  • Related autopopulated properties can now be referenced.

Decision Strategy Manager

Valid from Pega Version 7.1.3

Fixes were made that improve the configuration and execution of Batch Decisions. In particular,  the capability to use Structured Data has been enhanced. Some notable improvements have also been made to the UI of Visual Business Director.

  • The structured data input configuration will now work even though there is no data.
  • VBD has been enhanced to work with Version 7.1.
  • The structured data input configuration will now work with nested structures.
  • Association rules from Version 6.3 will now work with 7.1 structured data.

Integration

Valid from Pega Version 7.1.3

Usability enhancements have been made to the integration wizards. The REST end-point integration has been improved, and XML parsing functionality has been enhanced.

  • PRPC services can return Report or Listview data as XML.
  • Work items may now be processed when accessing from a link in system-created emails.
  • An SMTP outage will not cause an application to stop working.
  • File listener will now read files using a leading asterisk (*).
  • XML Parse rule will handle schema validation.
  • PegaImageViewer will now work with Version 7.1.
  • Security measures are enhanced for SOAP connections to web services.
  • After generating rules using REST wizard, the Undo Generation button will delete all the generated rules.
  • Email wizard has been improved.

System Management

Valid from Pega Version 7.1.3

The PRPC installer has been enhanced to handle additional error conditions related to partial installs and duplicate keys; additionally, the hotfix rollback feature has been improved, and the Rulebase compare tool now supports HTTP(S) environments.

  • Rollback feature has been enhanced.
  • RuleBase Compare will work for secure (HTTPS) environments as well as  non-secure (HTTP) environments.
  • Install will gracefully handle the presence of a duplicate key during import.
  • When install fails, system will set tables back to original state.
  • Remote MBean methods will now work on multi-servant load-balancing systems.
  • Enhancements were made to harnesses in Split Schema systems.

Convert data instances into decision parameter rules

Valid from Pega Version 7.1.8

The Convert groups wizard is available in the Hierarchy landing page when the list of your propositions include decision data records.

Click Convert groups at the top of the landing page to use the wizard and to convert data instances into decision parameter rules. This conversion is necessary to make the existing proposition data instances available for revision management.

Update to the Data Flows rule

Valid from Pega Version 7.1.8

It is now possible to collect statistics for each active data flow. These include the number of processed records, records that caused errors and last processed records per shape, as well as historical throughput measured for the entire data flow.

There are two new patterns in the Data Flow rule:

  • Event Strategy - define this pattern to use an event strategy in a data flow and to connect a data stream and static data sources to an event strategy.
  • Filter - specify filter conditions and apply them to each element of the input flow 

Apart from this, the Merge pattern was updated to execute the flow when there is no data on the secondary branches and the Strategy pattern allows you to specify the class where you want to store your strategy results.

New Dynamic System Setting for proposition management

Valid from Pega Version 7.1.8

A new Dynamic System Setting affects the process of creating new groups on the Proposition Management landing page.

When the PropositionManagement/isOnlyVersionedProposition parameter is set to true, users can only create the versioned propositions.

When the PropositionManagement/isOnlyVersionedProposition parameter is set to false, the Create Group dialog allows users to create either the versioned or unversioned propositions (the Create versioned proposition data check box and the Decision data rule section are both displayed).

Identify, install, and manage hotfixes with the Hotfix Manager

Valid from Pega Version 7.1.8

Hotfixes are packages of files that address issues in Pega 7 and in participating Industry Applications. With Hotfix Manager, you can:

  • Scan your system for installed and missing critical hotfixes and create a report that you can provide to Pegasystems Support for diagnostic purposes.
  • Review the descriptions and contents of hotfixes.
  • Install, rollback, and commit hotfixes.
  • Manage hotfixes that include schema changes or require other special handling.

The Hotfix Manager replaces the Update Manager Hotfix Installer and System Scanner, both of which are deprecated. For more information, see Hotfix Manager identifies, installs, and manages hotfixes to Pega 7 and participating Industry Applications.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us