Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

User interface distortions in the Decision Manager portal

Valid from Pega Version 7.1.6

By default, the New Application wizard in Pega 7.1.6 configures new applications to include UI-Kit-7 in the list of application rulesets. This ruleset causes user interface distortions in the Decision Manager portal. Both applications created in previous maintenance level updates and applications created in Pega 7.1.6 that do not include the UI-Kit-7 dependency are not impacted by this known issue.

Workaround:

  1. Open the application record.
  2. In Application Rulesets, remove UI-Kit-7.
  3. Save the application record.

Use JDBC 4 compliant drivers for better performance

Valid from Pega Version 7.1.7

For better performance, ensure that you are using JDBC 4-compliant drivers.  For more information on supported and non-supported JDBC drivers, please reference the Platform Support Guide.

Use Tomcat 7 for better performance

Valid from Pega Version 7.1.7

For better performance with a Tomcat web server, use Tomcat 7.

Tomcat 6 has a limitation that causes the server to treat the JDBC driver as if it were a JDBC 3-compliant driver, even if the system is using a JDBC 4-compliant driver. Customers using Tomcat will see better performance if they upgrade to Tomcat 7 and use a JDBC 4-compliant driver.

Engine will not start if the incorrect JDBC driver is used

Valid from Pega Version 7.1.7

The engine will not start up if the incorrect JDBC driver is used. The following configurations are unsupported:

  • Using a Multi-tenant Oracle system with one of the Oracle JDBC drivers with issues (see the chart in the Platform Support Guide)
  • Using a Multi-tenant system with a JDBC 3 compliant driver, OR with Tomcat 6 (for more information on using tomcat with Pega 7.1.7, see Use Tomcat 7 for best performance)
  • Using Microsoft SQL Server with a JDBC 3 compliant driver, OR with Tomcat 6 (for more information on using tomcat with Pega 7.1.7, see Use Tomcat 7 for best performance)

When any of these unsupported configurations are encountered, Pega 7 will not start. Before this change, the engine would appear to start up properly, but would encounter issues during other parts of the engine startup or during actual use of the system.

User interface distortions in the Predictive Analytics Director portal

Valid from Pega Version 7.1.6

By default, the New Application wizard configures new applications to include UI-Kit-7 in the list of application rulesets. This ruleset causes user interface distortions in the Predictive Analytics Director portal. Applications created in maintenance level updates previous to Pega 7.1.6, and applications that do not include the UI-Kit-7 dependency, are not impacted by this known issue.

Workaround:

  1. Open the application record.
  2. In Application Rulesets, remove UI-Kit-7.
  3. Save the application record.

Noticeable differences between work objects created in the Decision Manager portal when compared to Designer Studio

Valid from Pega Version 7.1.7

In the Decision Manager portal, you create work objects by running flows in the enterprise application that serves as the base application for the application overlay. If the enterprise application does not include the UI-Kit-7 in its application rulesets, work objects can display differently in the Decision Manager portal when compared to Designer Studio because an application overlay is always configured to include the UI-Kit-7 ruleset.

Recommendation:

  1. Add the UI-Kit-7 ruleset dependency to the enterprise application.
  2. Redesign the user interface to comply with the UI-Kit-7 ruleset.

Update Existing Applications wizard will run for every upgrade

Valid from Pega Version 7.1.7

The upgrade process from a PRPC 5.x or 6.x system to Pega 7.1.7 now automatically runs the Update Existing Applications wizard. This may extend the time that the upgrade process takes to complete, depending on the version you are upgrading from and the number of rules in your application.

Upgrading to Pega 7.1.7 with an Oracle database requires new role permissions

Valid from Pega Version 7.1.7

When upgrading or updating from a prior version to Pega 7.1.7, if your system uses an Oracle database, an additional role is required to support the Reversability functionality. In addition to the Oracle privileges specified in the Install Guides, the role SELECT_CATALOG_ROLE is required. Verify that this role is present before beginning the upgrade or update.

IBM WebSphere Application Server V8: Edit the URL for Enabling System Management Application

Valid from Pega Version 7.1.7

WebSphere 8 does not correctly resolve the URL to enable System Management Application. As a workaround, when you configure the application server, you can do either of these actions:

  • Enter the full URL in the format:
    ​http://hostname:port/prsysmgmt/getnodes.action

  • Set the com.ibm.ws.webcontainer.redirectcontextroot property to true.

Add additional columns to customized work history tables

Valid from Pega Version 7.1.6

The standard work history table, pc_history_work, contains two new columns that return the latitude and longitude coordinate location of the action that prompted the history. Mobile devices can display this location as a street address. If you have a customized work history table, add these two columns to it:

  • <decimal name="pxLatitude" size="19" scale="9"/>
  • <decimal name="pxLongitude" size="19" scale="9"/>

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us