DCO and PMF integration is unavailable

Valid from Pega Version 7.1.5

DCO and PMF integration functionality is not available in this release. Related project management controls have been removed from the following:

  • System Settings landing page (Designer Studio > System > Settings > Project Management)
  • Application Profile landing page (Designer Studio > Application > Profile > Specifications)
  • Add/Edit Specification dialog

Restricted SMA access

Valid from Pega Version 7.1.5

System Management Application (SMA) remote connections are not supported on JBoss EAP 6.x. This means SMA users may only monitor locally connected systems. Ensure that the "Local JVM Connection..." option is selected when configuring PRPC nodes:

Screenshot generation runs on local client

Valid from Pega Version 7.1.8

If you generate screenshots to include in your application document, this process still runs on your local client. Additionally, you are still required to use Internet Explorer to use this feature.

Warning message when opening server-generated documents

Valid from Pega Version 7.1.8

Depending on your system configuration, the following warning message might be displayed when you open a document that was generated on the server.

If you click No, certain content (for example, Table of Contents) is not populated in the document. Instead, click Yes and save the document.

Warning message dialog

The warning message that displays

JavaMail API upgrade has potential SMTP configuration error

Valid from Pega Version 7.1.8

The JavaMail API has been upgraded from 1.4.1 to 1.5.2 in this release. This improvement provides greater compatibility and secure connectivity with leading industry email servers.

During the upgrade process, there is a known issue for some configurations of email servers, including Microsoft Exchange Server, that requires the use of an additional setting. After upgrading to this release, if you experience authentication failures when attempting to send email or test SMTP connectivity, do one of the following:

  • Recommended: Review the Microsoft Exchange email server settings to ensure proper configuration for SMTP authentication. In some cases, the use of port 587 instead of the traditional default SMTP port 25 has been shown to address this issue.
  • Create the following Dynamic System Setting with the value "true," and then restart email listeners:

Owning Ruleset: Pega-IntegrationEngine

Setting Purpose: javamail/NoAuthMechanismsRetry

After any email server configuration or upgrade, it is recommended that email listeners are re-tested without using this Dynamic System Setting.

See About Email Account data instances for information on configuring email account records.

Creating data page unit tests in Internet Explorer 8

Valid from Pega Version 7.1.8

When creating data page unit tests, selecting a parent property does not automatically select the child properties when using Internet Explorer 8.

Page and page list properties to be included in a data page unit test are selected on the Create test screen by selecting a check box next to the property name. Normally, selecting the check box of a parent property automatically selects all subsequent child properties as well. When using Internet Explorer 8, child properties are not automatically selected when the parent property's check box is selected.

The solution requires selecting all of the desired child properties individually. Select the check box next to each child property to include it in the data page unit test.

Schema not found error when importing a Rule-Admin-Product file

Valid from Pega Version 7.1.8

If you import a Rule-Admin-Product file (RAP) file that includes a schema that has a view, grammar parsing changes can mean that the Pega 7 Platform is unable to find the schema.

To enable the Pega 7 Platform to find the schema:

  1. Review the error message that indicates that the schema was not found and identify the following items:
    • The name of the schema that is causing the error
    • The table name in the format: wrong_schema_name.table_name...
    • The DDL that the Pega 7 Platform is trying to apply
  2. Use the table name to identify the correct schema name in your system. This schema is usually your data schema, but might also be an external database.
  3. Download the DDL.
  4. Correct the schema name and save the DDL.
  5. Manually apply the DDL.

WebSphere log error with Java 8 for Enterprise JavaBeans

Valid from Pega Version 7.1.8

For environments that are deployed by using Java 8 on IBM WebSphere Application Server version 8.5.5.9 through the last 8.5.5.x fix pack, the log might report that a class was not found when the application server attempts to start Enterprise JavaBeans. If Java EE functionality is not needed, no further action is required. However, to use Enterprise JavaBeans, see WebSphere log error with Java 8 for Enterprise JavaBeans.

Precision of Oracle Timestamp property when using RDB-Save

Valid from Pega Version 7.1.8

DateTime properties that are mapped to an Oracle Timestamp column will experience a loss of precision when they are saved using the RDB-Save method. When you use RDB-Save for an Oracle Timestamp, precision will be accurate to the second. For example, a value of 20171119T124745.006 will be saved as 20171119T124745. When you use Obj-Save, precision will be accurate to the millisecond. For more information, see DateTime property mapping in Oracle for Pega 7.

For Microsoft SQL Server deployments, change settings to create data types in Integration Designer

Valid from Pega Version 8.1

For on-premises deployments that use Microsoft SQL Server, set the Pega-Reporting/reporting/useMergeHintForRRquery dynamic system setting to true. If you do not configure this setting, you might not be able to create a new data type in Integration Designer that uses Pega as the system of record. Configure the setting as follows:

  • Owning ruleset: Pega-Reporting
  • Setting purpose: reporting/useMergeHintForRRquery
  • Value: true

For more information about configuring dynamic system settings, see Creating a dynamic system setting.