Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

WSDL generation error prevents invocation of SOAP services

Valid from Pega Version 8.4.2

Status

A Known Issue was introduced in the 8.4.2 Pega Platform patch release, which impacts both upgrades and new installations of that version.

Description

Due to changes introduced in the SOAP functionality for the case-mismatch error in SR-D98509/INC-119725, the WSDL is being generated for SOAP services with an incorrectly-capitalized element, which prevents the service from being invoked.  The element should be “name” instead of “Name”.

Workaround

Clients must perform the following workaround after they define a new SOAP connector in Pega Platform:

  1. To download the WSDL from Pega Platform:
    1. After using the SOAP Wizard (Dev Studio > Configure > Integration > Services > Service Wizard) the WSDL URL is shown at the bottom right of the Dev Studio screen.
    2. Click the URL to display the XML.
    3. Save the WSDL file to your local system.
  2. In the text editor of your choice, modify "Name" to "name" in every <element “name” = … > tag in the WDSL.
  3. Save your changes to the local file.
  4. To reload the WSDL into Pega Platform:
    1. In Dev Studio, open the Configure menu.
    2. Select Integration > Connectors > Create SOAP Integration.
    3. In the New SOAP integration wizard, select Upload WSDL from File.
    4. Complete the upload using the wizard prompts.

This is a design-time issue, not a run-time issue; therefore, clients only have to perform this workaround process once. Existing SOAP services should not be impacted; however, if clients modify an existing SOAP service definition by re-running the wizard, clients must reapply the workaround for Pega Platform to recognize the SOAP definition changes.  

Resolution

This issue will be addressed in the Pega Platform Patch Release 8.4.3.  Clients who upgrade to that version or later should not see this issue.

Real-time pulse processing for multinode systems

Valid from Pega Version 7.1.9

Multinode development environments now use real-time pulse processing. Previously, when a change was made on one node, the pulse processing interval could take a minute or more for that change to be reflected on another node. Now, when a rule is changed on one node, that change is immediately reflected on all the other nodes in the cluster. This change helps to ensure that users are running a rule on the same node as where the rule was changed.

Verifying that a Pega 7 Platform instance is running

Valid from Pega Version 7.1.9

You can verify whether a Pega 7 Platform instance is up and running by entering this URL: http://<<hostName:port/contextName>>/PRRestService/monitor/pingservice/ping

The Pega 7 Platform Engine responds with HTTP Response Code 200 if the instance is available. The response contains JSON text in the format { "duration":"<time in milliseconds>" }. Any other response codes or timeout indicate that the instance is unavailable.

Internet Application Composer (IAC) renamed to Pega Web Mashup

Valid from Pega Version 7.1.9

The name of Internet Application Composer (IAC) has changed to Pega Web Mashup.

For more information, see Pega web mashups for embedding Pega Platform UI in external web pages.

FTP server records enhanced for SSH FTP

Valid from Pega Version 7.1.9

When using SSH FTP (SFTP) in an FTP Server record, you can securely transfer files by using SSH keys. You can enable and configure SFTP by opening the FTP server record and completing the fields in the Protocol section.

For more information, see SSH FTP for FTP server records.

Database storage used for passivation in High Availability mode

Valid from Pega Version 7.1.9

When an application is running in High Availability mode, the value attribute for initialization/​persistrequestor/storage in the prconfig.xml file or the Dynamic System Settings​ now defaults to "database."

Previously, applications running in High Availability mode required shared passivation, where either initialization/​persistrequestor/storage was set to “OnTimeout” or a custom passivation mechanism was used. The change to using database by default provides persistent storage for passivation, and provides control for the landing page for High Availability.

For more information, see Understanding passivation and requestor timeouts and the High Availability Administration Guide.

Primary key constraint error when using JBoss

Valid from Pega Version 7.1.9

A primary key constraint violation exception might occur in the following situation: you use JBoss EAP 6.4 and SQL Server 2012 with a JDBC 4 driver, and you use two or more file listeners or JMS MDB listeners with concurrent threads that create work objects that use multiple files. If a primary key constraint violation exception occurs in this situation, update the data source configuration file to set the jta parameter to true. For example, set <datasource jta="true" jndi-name-"java:/jdbc/PegaRULES>.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us