Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Supported JDBC drivers

Valid from Pega Version 7.1.1

Pega 7.1.1 supports Java 6 and Java 7 SDKs only. Ensure that the JDBC driver you are using supports those versions of Java. See your database installation or upgrade documentation for additional information.

DatabaseJava 6Java 7
Oracleojdbc6.jarojdbc7.jar
MSQLsqljdbc4.jarsqljdbc4.jar
DB2 LUWdb2jcc4.jardb2jcc4.jar
DB2 z/OS*db2jcc4.jar or jdb2jcc.jar**db2jcc4.jar
PostgreSQLpostgresql-9.1-903.jdbc4.jar***postgresql-9.1-903.jdbc4.jar

* JDBC drivers are only available from the DB2 for z/OS product. Additionally, you need db2jcc_license_cisuz.jar in the same directory as db2jcc4.jar.

** The db2jcc.jar has been deprecated and may not be supported in future releases.

*** This .jar file is required for PostgreSQL version 9.1.x.

Turn off saved connections in WebLogic

Valid from Pega Version 7.1.1

PRPC caches connections in thread-local storage. When using a WebLogic application server, set database/savedconnections to FALSE to avoid incorrectly saved, container-managed transactions. You can make this update through JNDI settings or by adding an entry to the prconfig.xml, for example:

<env name="database/savedconnections" value="false" />

IE8 hangs on large imports

Valid from Pega Version 7.1.1

IE8 users may experience a hung process when running the Designer Studio > Application > Distribution > Import wizard. This issue is related to low-capacity networks and large (300+ MB) archive files.

Although the processing symbol prevents you from proceeding to the next step in the wizard, the file is still imported to the server. As a workaround, you can:

  1. Wait approximately eight minutes for the file to import.
  2. Close and restart the wizard.
  3. Click Next to skip the upload step.
  4. Select the name of your file from the list of import files.
  5. Complete the remaining steps in the wizard.

Required DB2 settings

Valid from Pega Version 7.1.1

For customers using the DB2 Version 4 drivers (“db2jcc4.jar”), it is necessary to set the custom connection property useJDBC4ColumnNameAndLabelSemantics to “false”.   

For customers using DB2 with WebSphere, the useJDBC4ColumnNameAndLabelSemantics property in the DB2 data source needs to be changed from a Boolean to an Integer and set to "2". 

EAR support for JBoss EAP 6

Valid from Pega Version 7.1.5

PRPC deployment in JBoss EAP 6 as an EAR archive is now supported. 

If you need to deploy the JBoss EAR file, go to My Support Portal and submit a Support Request. GCS can assist you with the procedure.

Tracer supports SOAP messages

Valid from Pega Version 7.1.5

You can now select a Tracer Settings option to display SOAP connector and services messages in Tracer, which provides users with a better understanding of SOAP connector behavior.

Actionable error message in integration wizards

Valid from Pega Version 7.1.5

Improvements have been made to the integration wizards for SOAP, SAP, and .NET that enhance the user experience by providing clearer, actionable error messages when there are problems with WSDL uploads; letting you edit the endpoint while creating or testing the integration; clarifying how the data source class layer is reused and removing confusing terms; and adding an option in Tracer to view SOAP messages generated or received by integrations.

Small distribution kit

Valid from Pega Version 7.1.5

A new “small” release distribution format for Maintenance Levels (ML) is now available, designed to significantly increase adoption via: 

  • Minimal package size and faster download time
  • Minimal install time via tactical changes to the upgrade implementation and process

This kit contains streamlined installers (both UI and command-line installers) and specialized error handling for ML updates (for example, a “small” kit will only work if an existing version of the same release is already installed). 

The kit assembly has also been automated, which includes the construction of a PRPC_Rules.jar archive containing cumulative rules since the GA release. 

A “small” kit will work for any prior ML release within a major release (for example, the “small” ML5 distribution kit will update any customer on 7.1 ML1 through 7.1 ML4).

Improved data page performance

Valid from Pega Version 7.1.5

Improvements have been made with queueing and processing of asynchronously-loaded data pages to reduce the number of calls to the database and avoid generating performance problems because of unneeded asynchronous requests.

Restricted SMA access

Valid from Pega Version 7.1.5

System Management Application (SMA) remote connections are not supported on JBoss EAP 6.x. This means SMA users may only monitor locally connected systems. Ensure that the "Local JVM Connection..." option is selected when configuring PRPC nodes:

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us