Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Decision Data Store data sets can be used only on DNodes

Valid from Pega Version 7.1.8

Data flows that contain Decision Data Store data sets as the primary or secondary source must be created and executed only on DNodes.

Data flows are not restarted automatically after application server restart

Valid from Pega Version 7.1.8

When you restart the application server or the Pega 7 server, you stop the execution of your data flows. The interrupted batch and real-time runs are marked as Failed

Recommendation:

  • Go to the Designer StudioDecisioning > Decisions > Data Flows > Batch processing tab and start the failed batch runs.
  • Go to the Designer StudioDecisioning > Decisions > Data Flows > Real-time processing tab and activate the failed real-time runs.

 

Value list and value group properties are not supported inside data flows

Valid from Pega Version 7.1.8

Value list and value group properties are not supported inside data flows, and you need to instead use other property types.

See the Pega 7 developer help to check all available property types.

Data flow preview size is fixed to 10

Valid from Pega Version 7.1.8

The Preview option for each shape in data flows returns the first 10 records. This value is fixed and currently cannot be changed.

Data Flow transformation shapes cannot be used in combination with the Compose or Merge shapes

Valid from Pega Version 7.1.8

When you reference another data flow from a data flow that contains the Compose or Merge shape, the referenced data flow cannot contain transformation shapes (EventStrategy, Decision strategy, Convert).

Data flow validation does not currently prevent you from designing a data flow that goes against this design pattern. Make sure that your data flows follow this design pattern by checking the referenced and referencing data flows.

 

Data flow destination is resolved at assembly time

Valid from Pega Version 7.1.8

Data flow execution always uses the design-time destination data sets or destination data flows, regardless of the input records at run time.

Example:

You create a data flow and set the destination to a specific data set. In the data flow, you use a strategy that produces some results. Regardless of these results, the execution of your data flow always uses the destination data set that you specified when you designed the data flow.    

The same applies when you set the destination to a data flow.

 

 

Schema not found error when importing a Rule-Admin-Product file

Valid from Pega Version 7.1.8

If you import a Rule-Admin-Product file (RAP) file that includes a schema that has a view, grammar parsing changes can mean that the Pega 7 Platform is unable to find the schema.

To enable the Pega 7 Platform to find the schema:

  1. Review the error message that indicates that the schema was not found and identify the following items:
    • The name of the schema that is causing the error
    • The table name in the format: wrong_schema_name.table_name...
    • The DDL that the Pega 7 Platform is trying to apply
  2. Use the table name to identify the correct schema name in your system. This schema is usually your data schema, but might also be an external database.
  3. Download the DDL.
  4. Correct the schema name and save the DDL.
  5. Manually apply the DDL.

Node description cannot match application server node name

Valid from Pega Version 6.3 SP1

A node's Short Description should not be the same value as the application server node name. If the node's Short Description is changed to be the same value as the application server node name, then the node description is automatically changed back to the original value after a system restart.

WebSphere log error with Java 8 for Enterprise JavaBeans

Valid from Pega Version 7.1.8

For environments that are deployed by using Java 8 on IBM WebSphere Application Server version 8.5.5.9 through the last 8.5.5.x fix pack, the log might report that a class was not found when the application server attempts to start Enterprise JavaBeans. If Java EE functionality is not needed, no further action is required. However, to use Enterprise JavaBeans, see WebSphere log error with Java 8 for Enterprise JavaBeans.

Rule revalidation after updating properties without restarting nodes

Valid from Pega Version 8.2

When you update certain property attributes, such as a property's maximum length, rule types that reference the property might not reflect the change. You do not always have to restart nodes to revalidate the referencing rules when they cannot be resaved, for example, when they are in a locked ruleset. For Pega Platform™ 8.1 and later, for non-stream rules, such as activities, data transforms, and so on, use the reassemble API in Admin Studio or truncate the assembled classes table.

For stream rules, such as sections, harnesses, paragraphs, and so on, reassemble the rules and restart the nodes. For more information, see More about properties.

For previous versions of Pega Platform, use the System Management Application (SMA) to revalidate stream and non-stream rules.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us