Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Rules can no longer access Pega internal Java packages

Valid from Pega Version 8.4

You can no longer create rules that access Java packages that reference internal APIs (syntax com.pega.platform.*.internal*). This change does not affect rules that access Pega public API packages.

If you encounter issues when running existing rules that reference internal Pega APIs, contact Pega Support.

Upgrade impact

After an upgrade to 8.4 and later, clients can no longer save new or modified rules that access Pega internal APIs; existing rules that reference internal APIs can still be run but cannot be modified. 

What steps are required to update the application to be compatible with this change?

Following a software upgrade to 8.4 or later, clients can refactor existing rules into guardrail compliant rules. To find rules to refactor, run the validation tool from designer studio (Application > Tools > Validation) to identify what rules fail validation; failed rules that include the message "Test compilation failed : Illegal internal class reference : com.pega.internal.XYZ" can updated to reference appropriate APIs.

Changes to the architecture of the Data Flow service

Valid from Pega Version 8.4

In Pega Platform™ 8.4, the architecture of batch and real-time data flows uses improved node handling to increase the stability of data flow runs. As a result, there are fewer interactions with the database and between the nodes, resulting in increased resilience of the Data Flow service.

If you upgrade from a previous version of Pega Plaftorm, see the following list for an overview of the changes in the behavior of the Data Flow service compared to previous versions:

Responsiveness

Nodes no longer communicate and trigger each other, but run periodic tasks instead. As such, triggering a new run does not cause the service nodes to immediately start the run. Instead, the run starts a few seconds later. The same applies to user actions such as stopping, starting, and updating the run. The system also processes topology changes as periodic tasks, so it might take a few minutes for new nodes to join runs, or for partitions to redistribute when a node leaves a run.

Updates to lifecycle actions

To make lifecycle actions more intuitive, the Stop action consolidates both the Stop and Pause actions. The Start action consolidates both the Resume and Start actions.

You can resume or restart stopped and failed runs with the Start and Restart actions. The Start action is only available for resumable runs and continues the run from where it stopped. The Restart action causes the run to process from the beginning. Completed runs can only be restarted. If a run completes with failures, you can restart it from the beginning, or process only the errors by using the Reprocess failures action.

Starting a run

New data flow runs have the Initializing status, and start automatically. You no longer need to manually start a new run, so the New status is now removed.

If there are no nodes available to process a run, the run gets the Queued status and waits for an available node.

Triggering pre- and post-activities

The system now triggers pre-activities on a random service node, rather than on the node that triggered the run.

The system triggers post-activities only for runs that complete, fail, or complete with failures. If you manually stop a run with the Stop action, the post-activity does not trigger. However, restarting the run with the Restart action triggers first the post-activity, and then the pre-activity.

You can no longer choose to run pre- and post-activities on all nodes.

Selecting a node fail policy

For resumable runs, you can no longer select a node fail policy. If a node fails, the partitions assigned to that node automatically continue the run on different nodes.

For non-resumable runs, you can choose to restart the partitions assigned to the failed node on different nodes, or to fail the partitions assigned to the failed node.

No service nodes and active runs

If the last data flow node for an in-progress run fails, the run remains in the In Progress state, even if no processing takes place. This behavior results from the fact that data flow architecture now prevents unrelated nodes from affecting runs.

Split schema upgrade instructions missing properties

Valid from Pega Version 7.1.3

If you upgraded from 5.x, 6.x, or 7.x using the instructions in previous versions of the upgrade guide, you may have neglected to set the properties below in your migrateSystem.properties file when you migrated your upgraded schema to the source system:

 

pega.rules.objects.generate=true

pega.rules.objects.apply=true

 

If these properties were not set during an upgrade that splits the schema, your environment does not have the indexes, triggers, and primary keys on the rules tables.

 

To check for this issue, see if the pr4_base and pr4_rule rules tables in your existing rules schema are missing primary keys. If they are, use the SQL scripts in the ResourceKit\MigrationRecoveryScripts directory of the release to cleanup duplicate rules that were created due to this issue. Follow the steps below to run the scripts.

To run the scripts on Microsoft SQL, Oracle, or PostgreSLQ

  1. Take down any app servers using the affected schema.
  2. Backup your database.
  3. Replace all instances of @RULES_SCHEMA in <database>_cleanDups.sql with the name of the schema that contains the pr4_base table.
  4. Run the <database>_cleanDups.sql script on the database with vendor tools (sqlPlus, SQL Server Management Studio, etc).
  5. Replace all instances of @RULES_SCHEMA in <database>_fix_vw_table.sql with the name of the schema that contains the pr4_base table.
  6. Run the <database>_fix_vw_table.sql script on the database with vendor tools (sqlPlus, SQL Server Management Studio, etc).
  7. Generate and apply the ddl using the command line generateDDL command. Check the installation guide for your database or the upgrade guide for details about how to use the generateDDL command line script.
  8. Rebuild the indexes for the tables in your rules schema using vendor tools. This is necessary so that your system runs at an optimum speed.
  9. Optionally upgrade to the latest release, at this point your database is ready to be upgraded or used depending on your needs.

      

To run the scripts on DB2 for LUW or z/OS

  1. Take down any app servers using the affected schema.
  2. Backup your database.
  3. Run the <database>_cleanDups.sql script on the database with vendor tools (UDB CLP, Data Studio, etc) to create the CLEANSE_RULES_DUPS stored procedure.
  4. Run the query Call CLEANSE_RULES_DUPS(‘<rulesSchema>’); where <rulesSchema> is the name of schema that contains the pr4_base table.
  5. After the previous step is complete drop the CLEANSE_RULES_DUPS procedure.
  6. Replace all instances of @RULES_SCHEMA in <database>_fix_vw_table.sql with the name of the schema that contains the pr4_base table.
  7. Run the <database>_fix_vw_table.sql script on the database with vendor tools (UDB CLP, Data Studio, etc).
  8. Generate and apply the ddl using the command line generateDDL command. Check the installation guide for your database or the upgrade guide for details about how to use the generateDDL command line script.
  9. Rebuild the indexes for the tables in your rules schema using vendor tools. This is necessary so that your system runs at an optimum speed.
  10. Optionally upgrade to the latest release. At this point your database is ready to be upgraded or used depending on your needs.

Custom database (DB) triggers are dropped during upgrade

Valid from Pega Version 7.1.8

The latest version of Pega 7 improves performance by no longer using database triggers to assist with System Pulse and Data-Rule-Summary processing, which is now done within the Pega 7 engine. As a result, DB triggers are no longer installed on either the pr_sys_updatescache or pr4_rule_vw tables.

When upgrading to the latest version of Pega 7, if you had previously implemented a custom database (DB) trigger on these tables, or a custom DB trigger that refers to these tables, it is removed during the upgrade process. No custom triggers are removed unless they reference these tables.

If you have custom DB triggers that reference the pr_sys_updatescache or pr4_rule_vw tables and perform other processing, those triggers must be reimplemented. When doing so, you must be careful to not modify the pr_sys_updatescache or pr4_rule_vw tables.

For more information, see Startup check removes custom DB triggers.

End of support for Netscape Plugin API in Google Chrome 45

Valid from Pega Version 7.1.8

Beginning with Chrome 45, which is expected to be available in September 2015, Google is ending support for browser plug-ins that rely on the Netscape Plugin API (NPAPI) architecture. These plug-ins include Microsoft Silverlight, Adobe Flash Player, and Java.

The Pega 7 Platform includes several optional features that use these plug-ins. For a detailed overview of these features, see Client-side technologies.

Rules Assembly cache is deprecated

Valid from Pega Version 7.3.1

Rules Assembly (RA) cache and custom settings for its corresponding fua/assemblyCacheModeprconfig.xml file setting are deprecated because they are obsolete. A warning is logged at startup if a custom (non-default) value is specified for fua/assemblyCacheMode in the prconfig.xml file. The functional behavior of the system is not affected.

Interactions in flows are no longer supported by the Run Interaction shape

Valid from Pega Version 7.3.1

The Run Interaction shape in flows has been replaced by the Run Data Flow shape, which supports running a single case data flow with a strategy. Flows that include the Run Interaction shape continue to work; however, you must now use the Utility shape to reference any new interactions that you create.

For more information, see Running a decision strategy from a flow and About Interaction rules.

Use of PegaRULES_Extract_Marker.txt to delete cache is deprecated

Valid from Pega Version 7.3.1

The PegaRULES_Extract_Marker.txt file is deprecated. The system uses the presence or absence of the PegaRULES_Extract_Market.txt file to determine at startup whether to delete the static content, service export, and lookup list file system-based caches. In the rare situation that you need to delete these caches manually, use the System Management Application (SMA) ETier Static Content Management page. Using SMA does not require restarting the node.

No longer supported translator configuration options

Valid from Pega Version 7.4

The following translator configuration options are not needed and are no longer supported. If you previously configured any of these system settings, remove them from the system settings to avoid a warning message. For example, if you set translator/useparserfamily, the following message is displayed at startup: "Translator option, 'translator/useparserfamily' is not needed and no longer supported. Remove this from the system settings."

  • translator/useparserfamily
  • translator/usecodegenerator
  • translator/usenativedouble
  • translator/optimization/use71BlockAnalysis
  • translator/optimization/use71ConstantFolding
  • translator/optimization/use71AssignmentTypeSimplification
  • translator/optimization/use71IntrinsicFunctions
  • translator/use71PropSetGeneration
  • translator/use71ParserAssignment
  • assembly/model/useBlock4ContiguousSets
  • /translator/pandc/comparepandcalgorithms
  • /translator/pandc/use6xalgorithms
  • /Compatibility/CheckForTopLevelClassMismatch

In addition, the com.pega.pegarules.generation.parseoverride bootstrap option is no longer supported. Remove this option from the system settings.

PegaDATA connection settings now required in the prconfig.xml file

Valid from Pega Version 7.4

If you use the default prconfig.xml file that is included with Pega® Platform, and you have not removed the PegaDATA connection settings, no action is required. If you use a custom prconfig.xml file, for example, for running tests, ensure that the database connection settings for PegaDATA are not blank.

For more information about the connection settings, see PegaDATA connection settings in the prconfig.xml file.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us