Restricted SMA access

Valid from Pega Version 7.1.5

System Management Application (SMA) remote connections are not supported on JBoss EAP 6.x. This means SMA users may only monitor locally connected systems. Ensure that the "Local JVM Connection..." option is selected when configuring PRPC nodes:

Node description cannot match application server node name

Valid from Pega Version 6.3 SP1

A node's Short Description should not be the same value as the application server node name. If the node's Short Description is changed to be the same value as the application server node name, then the node description is automatically changed back to the original value after a system restart.

High number of busy waits when using Oracle SecureFiles

Valid from Pega Version 7.2.1

You might experience a high number of buffer busy waits when using Oracle SecureFiles for BLOB storage. An Oracle buffer busy wait occurs when a session cannot access a database block in the buffer cache, because another session is either reading the block into the buffer or changing the buffer. As a best practice, use Oracle 11.2.0.4 or later, because earlier versions have more problems with SecureFiles. In addition, to minimize the number of busy waits, set the hidden Oracle parameter _securefiles_concurrency_estimate to 50, and partition the table by using a composite range hash partition that is based on the pxCreateDateTime and pzInskey columns.

For more information, see Troubleshooting: High number of busy waits when using Oracle SecureFiles.

Cannot send mobile push notifications when the Pega 7 Platform is hosted on WebSphere Application Server

Valid from Pega Version 7.2.1

Push notifications are not sent to Android or iOS mobile apps when the Pega 7 Platform is hosted on WebSphere Application Server.

Extract marker file not created at startup

Valid from Pega Version 7.2.1

The extract marker file (PegaRULES_Extract_Marker.txt) is not created at startup, because the rule utility libraries no longer need it. If you used to use the extract marker file to clear the static content file-based cache, to look up lists, or to control starting activities with web nodes, you can delete the contents of the PegaRULES temporary directory instead.

Upgrade/update fails if PostGIS is applied to PegaRULES or PegaDATA schema

Valid from Pega Version 7.2.1

If you use the PostGIS extension to a PostgreSQL database, upgrading or updating the Pega 7 Platform fails if the extension has been applied to either the PegaRULES or PegaDATA schema. PostGIS can be applied to any other schema.

No support for Android versions earlier than 4.4 on mobile devices

Valid from Pega Version 7.3

Pega® Platform dynamic layouts by default now use Flexbox-based rendering. As a result, mobile devices running on Android versions earlier than 4.4 are not supported in Pega Platform. Such devices cannot render correctly with Flexbox because the Pega Mobile Client includes the default stock browser on the Android operating system.

Package caching is not supported in offline-enabled applications built with the UI Kit 7 (09-01-01) portal

Valid from Pega Version 7.3

When you create an offline-enabled application in Pega® Platform, by default, it uses a portal with the UI Kit 7 (09-01-01) ruleset. In such a case, the package caching functionality cannot be used. You must either disable caching on the Advanced tab of the Access Group rule form, in the Offline Configuration section, or use an adaptive design instead of rendering different elements for different devices with the UI Kit 7 (09-01-01) ruleset.

For more information, see Access Group form - Completing the Advanced tab.

No video controllers displayed on Android 4.3 and earlier versions

Valid from Pega Version 7.3

When you preview a video clip within Pega® Mobile Client on a mobile device that runs Android 4.3 or earlier versions, video controllers are not displayed in full-screen mode.

Upgrades and updates from Pega 7.3 on MSSQL fail with column name mismatch

Valid from Pega Version 7.3

This failure applies only to upgrades and updates from Pega® Platform 7.3 on systems running Microsoft® SQL Server®. In Pega 7.3, the capitalization for the column name pc_work_agile.pzPvStream is incorrect. The correct capitalization is pzPVStream. To prevent upgrade and update failures, before you upgrade or update, run the following command from the Microsoft SQL Server Management Studio (SSMS) to rename the column:

EXEC sp_rename ‘data-schema-name.pc_work_agile.pzPvStream', 'pzPVStream', 'COLUMN'