Data synchronization does not resume after mobile app restart

Valid from Pega Version 8.3

If an offline-enabled mobile app that you build with Pega Infinity Mobile Client is stopped during an initial data synchronization session, the data synchronization does not resume when the mobile app is restarted. Users must not stop the mobile app before initial data synchronization finishes.

For more information about data synchronization, see Offline capability and Guidelines for creating an offline-enabled application.

Primary key constraint error when using JBoss

Valid from Pega Version 7.1.9

A primary key constraint violation exception might occur in the following situation: you use JBoss EAP 6.4 and SQL Server 2012 with a JDBC 4 driver, and you use two or more file listeners or JMS MDB listeners with concurrent threads that create work objects that use multiple files. If a primary key constraint violation exception occurs in this situation, update the data source configuration file to set the jta parameter to true. For example, set <datasource jta="true" jndi-name-"java:/jdbc/PegaRULES>.

No support for Android versions earlier than 4.4 on mobile devices

Valid from Pega Version 7.3

Pega® Platform dynamic layouts by default now use Flexbox-based rendering. As a result, mobile devices running on Android versions earlier than 4.4 are not supported in Pega Platform. Such devices cannot render correctly with Flexbox because the Pega Mobile Client includes the default stock browser on the Android operating system.

Package caching is not supported in offline-enabled applications built with the UI Kit 7 (09-01-01) portal

Valid from Pega Version 7.3

When you create an offline-enabled application in Pega® Platform, by default, it uses a portal with the UI Kit 7 (09-01-01) ruleset. In such a case, the package caching functionality cannot be used. You must either disable caching on the Advanced tab of the Access Group rule form, in the Offline Configuration section, or use an adaptive design instead of rendering different elements for different devices with the UI Kit 7 (09-01-01) ruleset.

For more information, see Access Group form - Completing the Advanced tab.

No video controllers displayed on Android 4.3 and earlier versions

Valid from Pega Version 7.3

When you preview a video clip within Pega® Mobile Client on a mobile device that runs Android 4.3 or earlier versions, video controllers are not displayed in full-screen mode.

Upgrades and updates from Pega 7.3 on MSSQL fail with column name mismatch

Valid from Pega Version 7.3

This failure applies only to upgrades and updates from Pega® Platform 7.3 on systems running Microsoft® SQL Server®. In Pega 7.3, the capitalization for the column name pc_work_agile.pzPvStream is incorrect. The correct capitalization is pzPVStream. To prevent upgrade and update failures, before you upgrade or update, run the following command from the Microsoft SQL Server Management Studio (SSMS) to rename the column:

EXEC sp_rename ‘data-schema-name.pc_work_agile.pzPvStream', 'pzPVStream', 'COLUMN'

Reports on pc_work_agile table fail in Pega 7.3 on MSSQL

Valid from Pega Version 7.3

This failure applies only to Pega® Platform 7.3 on systems running Microsoft SQL Server. In Pega 7.3, the capitalization for the column name pc_work_agile.pzPvStream is incorrect. The correct capitalization is pzPVStream. To prevent reporting failures on the pc_work_agile table, run the following command from the Microsoft SQL Server Management Studio (SSMS) to rename the column after you install Pega 7.3:

EXEC sp_rename ‘data-schema-name.pc_work_agile.pzPvStream', 'pzPVStream', 'COLUMN'

Nodes in a cluster do not see each other for Docker, multiple VMs, or multiple NICs setup

Valid from Pega Version 7.3

If a cluster is set up in Docker, or uses separate virtual machines (VMs) or multiple network interfaces, you must set the public address in the prconfig.xml file for each Pega® Platform node to avoid problems with node clustering. Add the <env name=”identification/cluster/public/address” value=”IP address”/> setting to specify the public address that is used by each node.

Security fields in JFrog Artifactory repository do not work

Valid from Pega Version 7.3

The fields in the Security section of the JFrog Artifactory repository rule form, including the Secure protocol field, the Truststore field, and the Keystore field, were not implemented. In the Pega™ Platform 7.3 Designer Studio help, disregard the optional Security section in step 4 of the Configuring a JFrog Artifactory or Amazon S3 repository connection help topic, and disregard the optional Security section in step 5 of the Creating a repository configuration help topic in the 7.3.1 Designer Studio help.