Required Oracle optimization parameter

Valid from Pega Version 7.1.3

To optimize performance, set the Oracle parameter optimizer_index_cost_adj to a value between 20 and 25. If this value is not set, the system can run exceedingly slowly, potentially blocking users from login.

Synchronized database and application server settings

Valid from Pega Version 7.1.3

Configure your database and application server to use the same time zone and character encoding to avoid conflicts.

Screenshot generation runs on local client

Valid from Pega Version 7.1.8

If you generate screenshots to include in your application document, this process still runs on your local client. Additionally, you are still required to use Internet Explorer to use this feature.

Warning message when opening server-generated documents

Valid from Pega Version 7.1.8

Depending on your system configuration, the following warning message might be displayed when you open a document that was generated on the server.

If you click No, certain content (for example, Table of Contents) is not populated in the document. Instead, click Yes and save the document.

Warning message dialog

The warning message that displays

Schema not found error when importing a Rule-Admin-Product file

Valid from Pega Version 7.1.8

If you import a Rule-Admin-Product file (RAP) file that includes a schema that has a view, grammar parsing changes can mean that the Pega 7 Platform is unable to find the schema.

To enable the Pega 7 Platform to find the schema:

  1. Review the error message that indicates that the schema was not found and identify the following items:
    • The name of the schema that is causing the error
    • The table name in the format: wrong_schema_name.table_name...
    • The DDL that the Pega 7 Platform is trying to apply
  2. Use the table name to identify the correct schema name in your system. This schema is usually your data schema, but might also be an external database.
  3. Download the DDL.
  4. Correct the schema name and save the DDL.
  5. Manually apply the DDL.

Node description cannot match application server node name

Valid from Pega Version 6.3 SP1

A node's Short Description should not be the same value as the application server node name. If the node's Short Description is changed to be the same value as the application server node name, then the node description is automatically changed back to the original value after a system restart.

WebSphere log error with Java 8 for Enterprise JavaBeans

Valid from Pega Version 7.1.8

For environments that are deployed by using Java 8 on IBM WebSphere Application Server version 8.5.5.9 through the last 8.5.5.x fix pack, the log might report that a class was not found when the application server attempts to start Enterprise JavaBeans. If Java EE functionality is not needed, no further action is required. However, to use Enterprise JavaBeans, see WebSphere log error with Java 8 for Enterprise JavaBeans.

Rule revalidation after updating properties without restarting nodes

Valid from Pega Version 8.2

When you update certain property attributes, such as a property's maximum length, rule types that reference the property might not reflect the change. You do not always have to restart nodes to revalidate the referencing rules when they cannot be resaved, for example, when they are in a locked ruleset. For Pega Platform™ 8.1 and later, for non-stream rules, such as activities, data transforms, and so on, use the reassemble API in Admin Studio or truncate the assembled classes table.

For stream rules, such as sections, harnesses, paragraphs, and so on, reassemble the rules and restart the nodes. For more information, see More about properties.

For previous versions of Pega Platform, use the System Management Application (SMA) to revalidate stream and non-stream rules.