Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Additional upgrade scripts for new columns

Valid from Pega Version 7.1.4

In Version 6.2, additional columns (Major, Minor, and Patch) containing ruleset Version information were added to 15 tables in the PRPC database. When upgrading from a pre-Pega 7 release, scripts must be manually run after the upgrade to populate these columns.

These scripts are located in the Resource Kit, under Additional Upgrade Scripts.

  • If upgrading to a single schema, run both scripts.
  • If upgrading to a split schema, run the _data script against the data schema and run the _rules script against the rules schema.
  Depending upon your database type (platform) and the size of your database, these scripts may require significant time and system resources to run.

Choose the scripts for your database type:

  • db2zos_rulesetversion_columns_data.sql
  • db2zos_rulesetversion_columns_rules.sql

 

  • mssql_rulesetversion_columns_data.sql
  • mssql_rulesetversion_columns_rules.sql

 

  • oracle_rulesetversion_columns_data.sql
  • oracle_rulesetversion_columns_rules.sql

 

  • postgres_rulesetversion_columns_data.sql
  • postgres_rulesetversion_columns_rules.sql

 

  • udb_rulesetversion_columns_data.sql
  • udb_rulesetversion_columns_rules.sql

Split schema systems require additional privileges

Valid from Pega Version 7.1.2

On Oracle split schema systems, add the following database privileges:

  • Grant DROP ANY INDEX to the Admin User.
  • Grant UNLIMITED TABLESPACE to the Rules User.

Use the Oracle Enterprise Manager to add these privileges or refer to the 7.1.3 Upgrade and Installation guides for Oracle.

Update Existing Applications wizard will run for every upgrade

Valid from Pega Version 7.1.7

The upgrade process from a PRPC 5.x or 6.x system to Pega 7.1.7 now automatically runs the Update Existing Applications wizard. This may extend the time that the upgrade process takes to complete, depending on the version you are upgrading from and the number of rules in your application.

Upgrading to Pega 7.1.7 with an Oracle database requires new role permissions

Valid from Pega Version 7.1.7

When upgrading or updating from a prior version to Pega 7.1.7, if your system uses an Oracle database, an additional role is required to support the Reversability functionality. In addition to the Oracle privileges specified in the Install Guides, the role SELECT_CATALOG_ROLE is required. Verify that this role is present before beginning the upgrade or update.

Add additional columns to customized work history tables

Valid from Pega Version 7.1.6

The standard work history table, pc_history_work, contains two new columns that return the latitude and longitude coordinate location of the action that prompted the history. Mobile devices can display this location as a street address. If you have a customized work history table, add these two columns to it:

  • <decimal name="pxLatitude" size="19" scale="9"/>
  • <decimal name="pxLongitude" size="19" scale="9"/>

Action required by admins for improved search

Valid from Pega Version 7.1.7

Starting November 13, 2014, after updating to or upgrading from a prior version to Pega 7.1.7, your system administrator must manually build all indexes for Elasticsearch before the system can automatically switch from Lucene to Elasticsearch.

It is recommended that you begin this manual re-indexing process for all enabled index types as soon as your update or upgrade is complete. The search landing page refers to Elasticsearch settings; during re-indexing, however, Lucene search continues to function to ensure that there is no interruption in search functions. When planning the re-indexing, be aware that the initial re-indexing requires significant resources on the host node and can be a lengthy process, depending on the number of rules and work objects in your system.

See the Pega 7.1.7 Upgrade Guide for information about manually indexing Elasticsearch.

Updates no longer require redeploying the prweb.war file or the application server-specific EAR file

Valid from Pega Version 7.1.7

Updating from Pega 7.1.7 to later versions of Pega 7 no longer requires that you redeploy the prweb.war file or the application server-specific EAR file.

Note that upgrades from versions prior to Pega 7.1.7 still require that you redeploy these files.

End of support for Microsoft Internet Explorer 9 and Internet Explorer 10

Valid from Pega Version 7.2

In accordance with Microsoft’s announcement to discontinue support for Internet Explorer 9 and Internet Explorer 10 in January 2016, Pega 7.2 will be the last version of the Pega 7 Platform to support Internet Explorer 9 and Internet Explorer 10.  

For Pega 7.2.1, you must upgrade to Microsoft Internet Explorer 11 or later, or use Google Chrome, Apple Safari, or Mozilla Firefox.

For more information about browser support, see the Platform Support Guide or contact Pegasystems Global Customer Support.

End of support for Microsoft Internet Explorer 9 in Pega 7.2.1

Valid from Pega Version 7.2.1

In accordance with Microsoft’s announcement to discontinue support for Internet Explorer 9, Pega 7.2.1 will not support Internet Explorer 9. You should not upgrade to Pega 7.2.1 if you are still using Internet Explorer 9. Otherwise, upgrade to Microsoft Internet Explorer 10 or later, or use Google Chrome, Apple Safari, or Mozilla Firefox, which support certain HTML5 and CSS3 standards not supported in Internet Explorer 9.

For more information about browser support, see the Platform Support Guide or contact Pegasystems Global Customer Support.

 

 

 

Discontinued support for multithreaded requestors

Valid from Pega Version 7.2.1

Multithreaded requestors are no longer supported in the Pega 7 Platform. Multithreading was previously specified by the prconfig setting initialization/allowMultiplePRThreads. If this setting is set to true when you upgrade to Pega 7.2.1, errors occur during the quiesce process.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us