Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Split schema upgrade instructions missing properties

Valid from Pega Version 7.1.3

If you upgraded from 5.x, 6.x, or 7.x using the instructions in previous versions of the upgrade guide, you may have neglected to set the properties below in your migrateSystem.properties file when you migrated your upgraded schema to the source system:

 

pega.rules.objects.generate=true

pega.rules.objects.apply=true

 

If these properties were not set during an upgrade that splits the schema, your environment does not have the indexes, triggers, and primary keys on the rules tables.

 

To check for this issue, see if the pr4_base and pr4_rule rules tables in your existing rules schema are missing primary keys. If they are, use the SQL scripts in the ResourceKit\MigrationRecoveryScripts directory of the release to cleanup duplicate rules that were created due to this issue. Follow the steps below to run the scripts.

To run the scripts on Microsoft SQL, Oracle, or PostgreSLQ

  1. Take down any app servers using the affected schema.
  2. Backup your database.
  3. Replace all instances of @RULES_SCHEMA in <database>_cleanDups.sql with the name of the schema that contains the pr4_base table.
  4. Run the <database>_cleanDups.sql script on the database with vendor tools (sqlPlus, SQL Server Management Studio, etc).
  5. Replace all instances of @RULES_SCHEMA in <database>_fix_vw_table.sql with the name of the schema that contains the pr4_base table.
  6. Run the <database>_fix_vw_table.sql script on the database with vendor tools (sqlPlus, SQL Server Management Studio, etc).
  7. Generate and apply the ddl using the command line generateDDL command. Check the installation guide for your database or the upgrade guide for details about how to use the generateDDL command line script.
  8. Rebuild the indexes for the tables in your rules schema using vendor tools. This is necessary so that your system runs at an optimum speed.
  9. Optionally upgrade to the latest release, at this point your database is ready to be upgraded or used depending on your needs.

      

To run the scripts on DB2 for LUW or z/OS

  1. Take down any app servers using the affected schema.
  2. Backup your database.
  3. Run the <database>_cleanDups.sql script on the database with vendor tools (UDB CLP, Data Studio, etc) to create the CLEANSE_RULES_DUPS stored procedure.
  4. Run the query Call CLEANSE_RULES_DUPS(‘<rulesSchema>’); where <rulesSchema> is the name of schema that contains the pr4_base table.
  5. After the previous step is complete drop the CLEANSE_RULES_DUPS procedure.
  6. Replace all instances of @RULES_SCHEMA in <database>_fix_vw_table.sql with the name of the schema that contains the pr4_base table.
  7. Run the <database>_fix_vw_table.sql script on the database with vendor tools (UDB CLP, Data Studio, etc).
  8. Generate and apply the ddl using the command line generateDDL command. Check the installation guide for your database or the upgrade guide for details about how to use the generateDDL command line script.
  9. Rebuild the indexes for the tables in your rules schema using vendor tools. This is necessary so that your system runs at an optimum speed.
  10. Optionally upgrade to the latest release. At this point your database is ready to be upgraded or used depending on your needs.

Split schema systems require additional privileges

Valid from Pega Version 7.1.2

On Oracle split schema systems, add the following database privileges:

  • Grant DROP ANY INDEX to the Admin User.
  • Grant UNLIMITED TABLESPACE to the Rules User.

Use the Oracle Enterprise Manager to add these privileges or refer to the 7.1.3 Upgrade and Installation guides for Oracle.

End of support for Microsoft Internet Explorer 9 in Pega 7.2.1

Valid from Pega Version 7.2.1

In accordance with Microsoft’s announcement to discontinue support for Internet Explorer 9, Pega 7.2.1 will not support Internet Explorer 9. You should not upgrade to Pega 7.2.1 if you are still using Internet Explorer 9. Otherwise, upgrade to Microsoft Internet Explorer 10 or later, or use Google Chrome, Apple Safari, or Mozilla Firefox, which support certain HTML5 and CSS3 standards not supported in Internet Explorer 9.

For more information about browser support, see the Platform Support Guide or contact Pegasystems Global Customer Support.

 

 

 

Discontinued support for multithreaded requestors

Valid from Pega Version 7.2.1

Multithreaded requestors are no longer supported in the Pega 7 Platform. Multithreading was previously specified by the prconfig setting initialization/allowMultiplePRThreads. If this setting is set to true when you upgrade to Pega 7.2.1, errors occur during the quiesce process.

Child case queries can be slow after upgrade

Valid from Pega Version 7.2.1

After upgrading, performance might be slow when you run queries on child cases for work tables that existed prior to the upgrade. This issue is often indicated by PEGA0005 (query time exceeded limit) alerts that can be correlated to these queries in the logs. To resolve the issue, add a database index to each of your work tables by using a multicolumn index on the pxCoverInsKey, pxObjClass, and pyStatusWork columns.

For more information, see Performance improvements for child case queries.

Existing operator IDs during upgrades and updates

Valid from Pega Version 7.2.2

Upgrades and updates are always performed in secured mode to help prevent unauthorized access to your system. In secured mode, the [email protected] operator ID is always overwritten, but other existing standard operator IDs are not modified. New operator IDs are inserted in secured mode. For more information, see the Deployment Guide for your environment.

No longer supported translator configuration options

Valid from Pega Version 7.4

The following translator configuration options are not needed and are no longer supported. If you previously configured any of these system settings, remove them from the system settings to avoid a warning message. For example, if you set translator/useparserfamily, the following message is displayed at startup: "Translator option, 'translator/useparserfamily' is not needed and no longer supported. Remove this from the system settings."

  • translator/useparserfamily
  • translator/usecodegenerator
  • translator/usenativedouble
  • translator/optimization/use71BlockAnalysis
  • translator/optimization/use71ConstantFolding
  • translator/optimization/use71AssignmentTypeSimplification
  • translator/optimization/use71IntrinsicFunctions
  • translator/use71PropSetGeneration
  • translator/use71ParserAssignment
  • assembly/model/useBlock4ContiguousSets
  • /translator/pandc/comparepandcalgorithms
  • /translator/pandc/use6xalgorithms
  • /Compatibility/CheckForTopLevelClassMismatch

In addition, the com.pega.pegarules.generation.parseoverride bootstrap option is no longer supported. Remove this option from the system settings.

PegaDATA connection settings now required in the prconfig.xml file

Valid from Pega Version 7.4

If you use the default prconfig.xml file that is included with Pega® Platform, and you have not removed the PegaDATA connection settings, no action is required. If you use a custom prconfig.xml file, for example, for running tests, ensure that the database connection settings for PegaDATA are not blank.

For more information about the connection settings, see PegaDATA connection settings in the prconfig.xml file.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us