Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Remove JVM settings from prior installations

Valid from Pega Version 7.1.1

JVM memory settings ​defined in the setupDatabase.properties file to support a prior installation need to be removed. 

Memory settings are now handled by the installation program. Duplicating these settings may cause installation or upgrade failures. 

Required DB2 settings for LUW and z/OS

Valid from Pega Version 7.1.1

Installations on DB2 databases for LUW and z/OS require a minimum logging file size (4096) and a default table space page size (32K).

To set the table space page size to 32K:

  1. Stop the system.
  2. Rename one table (“TableX”) to backup (“TableXBackup”).
  3. Create a new table space that uses a 32K page size.
  4. Copy “TableXBackup” to “TableX” in the new table space.
  5. Restart the system and test to verify there are no issues.
  6. Drop the backup table (or keep it for future reference).

Additional information is available in the "Adjusting the log space size in upgraded databases" article: https://pic.dhe.ibm.com/infocenter/db2luw/v9r7/index.jsp?topic=%2Fcom.ibm.db2.luw.qb.upgrade.doc%2Fdoc%2Ft0023289.html

No direct upgrade to multitenant setup

Valid from Pega Version 7.1.1

It is not possible to upgrade directly to a multi-tenant setup. A Pega 7 application may be exported and then imported into a multi-tenant system, with the administrator making the decision as to whether this then becomes a tenant system or a shared system.

 

Applications developed in versions prior to Pega 7 must be upgraded to a Pega 7 standard system, and then exported and imported into a multi-tenant system. See the Multitenancy Administration Guide for full details.

Upgrade changes system name

Valid from Pega Version 7.1.1

As of Pega 7.1.7, the following renaming behavior no longer occurs.

The upgrade process renames your system to “PRPC” and modifies any custom requestor rules in your application to use this name. After the upgrade completes, you must apply these changes to revert your system:

  1. Identify all custom requestor rules (browser, batch, app, portal) with access groups that point to prior versions of PRPC.
  2. Open the relevant access groups (for example, PRPC:Unauthenticated and PRPC:Agents) and update the name and version fields to point to the current PegaRULES application.
  3. Reset your system name to its original value. You can set the Dynamic System Setting prconfig/identification/systemName/default or use the Designer Studio > System > Settings > System Name landing page.
  4. Restart the system.

Run cleanup.bat/sh script only before upgrading

Valid from Pega Version 7.1.1

Prior to upgrading the rulebase, you can optionally run the cleanup.bat/sh script to remove older rules from the database.

Run this script before you upgrade your rulebase, or the script may delete needed rulesets. For more information about running the cleanup.bat/sh script, refer to the Upgrade Guide specific to your release version.

No longer supported translator configuration options

Valid from Pega Version 7.4

The following translator configuration options are not needed and are no longer supported. If you previously configured any of these system settings, remove them from the system settings to avoid a warning message. For example, if you set translator/useparserfamily, the following message is displayed at startup: "Translator option, 'translator/useparserfamily' is not needed and no longer supported. Remove this from the system settings."

  • translator/useparserfamily
  • translator/usecodegenerator
  • translator/usenativedouble
  • translator/optimization/use71BlockAnalysis
  • translator/optimization/use71ConstantFolding
  • translator/optimization/use71AssignmentTypeSimplification
  • translator/optimization/use71IntrinsicFunctions
  • translator/use71PropSetGeneration
  • translator/use71ParserAssignment
  • assembly/model/useBlock4ContiguousSets
  • /translator/pandc/comparepandcalgorithms
  • /translator/pandc/use6xalgorithms
  • /Compatibility/CheckForTopLevelClassMismatch

In addition, the com.pega.pegarules.generation.parseoverride bootstrap option is no longer supported. Remove this option from the system settings.

PegaDATA connection settings now required in the prconfig.xml file

Valid from Pega Version 7.4

If you use the default prconfig.xml file that is included with Pega® Platform, and you have not removed the PegaDATA connection settings, no action is required. If you use a custom prconfig.xml file, for example, for running tests, ensure that the database connection settings for PegaDATA are not blank.

For more information about the connection settings, see PegaDATA connection settings in the prconfig.xml file.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us