Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

Split schema upgrade instructions missing properties

Valid from Pega Version 7.1.3

If you upgraded from 5.x, 6.x, or 7.x using the instructions in previous versions of the upgrade guide, you may have neglected to set the properties below in your migrateSystem.properties file when you migrated your upgraded schema to the source system:

 

pega.rules.objects.generate=true

pega.rules.objects.apply=true

 

If these properties were not set during an upgrade that splits the schema, your environment does not have the indexes, triggers, and primary keys on the rules tables.

 

To check for this issue, see if the pr4_base and pr4_rule rules tables in your existing rules schema are missing primary keys. If they are, use the SQL scripts in the ResourceKit\MigrationRecoveryScripts directory of the release to cleanup duplicate rules that were created due to this issue. Follow the steps below to run the scripts.

To run the scripts on Microsoft SQL, Oracle, or PostgreSLQ

  1. Take down any app servers using the affected schema.
  2. Backup your database.
  3. Replace all instances of @RULES_SCHEMA in <database>_cleanDups.sql with the name of the schema that contains the pr4_base table.
  4. Run the <database>_cleanDups.sql script on the database with vendor tools (sqlPlus, SQL Server Management Studio, etc).
  5. Replace all instances of @RULES_SCHEMA in <database>_fix_vw_table.sql with the name of the schema that contains the pr4_base table.
  6. Run the <database>_fix_vw_table.sql script on the database with vendor tools (sqlPlus, SQL Server Management Studio, etc).
  7. Generate and apply the ddl using the command line generateDDL command. Check the installation guide for your database or the upgrade guide for details about how to use the generateDDL command line script.
  8. Rebuild the indexes for the tables in your rules schema using vendor tools. This is necessary so that your system runs at an optimum speed.
  9. Optionally upgrade to the latest release, at this point your database is ready to be upgraded or used depending on your needs.

      

To run the scripts on DB2 for LUW or z/OS

  1. Take down any app servers using the affected schema.
  2. Backup your database.
  3. Run the <database>_cleanDups.sql script on the database with vendor tools (UDB CLP, Data Studio, etc) to create the CLEANSE_RULES_DUPS stored procedure.
  4. Run the query Call CLEANSE_RULES_DUPS(‘<rulesSchema>’); where <rulesSchema> is the name of schema that contains the pr4_base table.
  5. After the previous step is complete drop the CLEANSE_RULES_DUPS procedure.
  6. Replace all instances of @RULES_SCHEMA in <database>_fix_vw_table.sql with the name of the schema that contains the pr4_base table.
  7. Run the <database>_fix_vw_table.sql script on the database with vendor tools (UDB CLP, Data Studio, etc).
  8. Generate and apply the ddl using the command line generateDDL command. Check the installation guide for your database or the upgrade guide for details about how to use the generateDDL command line script.
  9. Rebuild the indexes for the tables in your rules schema using vendor tools. This is necessary so that your system runs at an optimum speed.
  10. Optionally upgrade to the latest release. At this point your database is ready to be upgraded or used depending on your needs.

Custom database (DB) triggers are dropped during upgrade

Valid from Pega Version 7.1.8

The latest version of Pega 7 improves performance by no longer using database triggers to assist with System Pulse and Data-Rule-Summary processing, which is now done within the Pega 7 engine. As a result, DB triggers are no longer installed on either the pr_sys_updatescache or pr4_rule_vw tables.

When upgrading to the latest version of Pega 7, if you had previously implemented a custom database (DB) trigger on these tables, or a custom DB trigger that refers to these tables, it is removed during the upgrade process. No custom triggers are removed unless they reference these tables.

If you have custom DB triggers that reference the pr_sys_updatescache or pr4_rule_vw tables and perform other processing, those triggers must be reimplemented. When doing so, you must be careful to not modify the pr_sys_updatescache or pr4_rule_vw tables.

For more information, see Startup check removes custom DB triggers.

End of support for Netscape Plugin API in Google Chrome 45

Valid from Pega Version 7.1.8

Beginning with Chrome 45, which is expected to be available in September 2015, Google is ending support for browser plug-ins that rely on the Netscape Plugin API (NPAPI) architecture. These plug-ins include Microsoft Silverlight, Adobe Flash Player, and Java.

The Pega 7 Platform includes several optional features that use these plug-ins. For a detailed overview of these features, see Client-side technologies.