Stages and Steps may not appear as expected

Valid from Pega Version 7.1.5

There are some unique configurations of the newly enhanced pxDisplayStages gadget that can lead to case type "Stages and Steps" appearing more than once or not at all.  In the event that your application experiences one of these scenarios, the recommended work around is to relocate the gadget:

  • Add pxDisplayStages to the pyCaseContainer section (or equivalent)
  • Remove pxDisplayStages from the pyCaseActionArea section (or equivalent).

Text Input control number type does not validate

Valid from Pega Version 7.1.5

When a Text Input control type is set to "Number" in the Presentation tab:

  • Validation does not trigger and the field is blanked out when a user submits the form.
  • If a value other than a number is entered, the browser sends an empty value, and the value is not validated.
  • In the Clipboard, the field value displays as empty.
  • If the field is required, the validation displays.

This issue occurs when using both the Chrome and Safari web browsers, and is a result of browser behavior for the HTML5 type=“number”. To fix this issue when using these browsers, do not use the "Number" type in Presentation tab of a Text Input control. Instead, the type should be set to "Text".

Unclear error message when saving shared class instance in tenant layer

Valid from Pega Version 7.1.5

If you attempt to save a shared class instance from the tenant layer, Pega 7 displays this message:

This record has x errors. Save Failed: There was a problem saving an instance of class: Error Code: <none> SQL State: <none> Message: <none>

You cannot save a shared instance from the tenant layer if that instance cannot be overridden.

Email approval and instantiation not supported on multitenant systems

Valid from Pega Version 7.2.1

The Enable email approval check box appears on the General tab of an approval step in Case Designer in multitenant systems. It also appears on the Approval shape in Designer Studio. In addition, in Designer Studio, the Settings tab in Case Designer displays the option to configure email instantiation. However, because configuring email listeners is not supported on multitenant systems, you cannot enable email approval or email instantiation.

Ignore locale settings requires refresh after server restarts

Valid from Pega Version 7.2.1

The Ignore locale check box in operator preferences is selected to display Designer Studio in U.S. English. After a server restarts, screens initially ignore this setting. When the screen is refreshed or reopened, the screen is rendered as expected.

Flexbox-based dynamic layouts not supported for Android 4.4 and earlier

Valid from Pega Version 7.2.1

Flexbox-based dynamic layouts are not supported in Android 4.4 and earlier. When developing applications to be used on devices running Android 4.4 and earlier, use the inline-block layout mode for dynamic layouts.

Pega Survey documentation refers to deprecated field

Valid from Pega Version 7.2.1

The documentation for Pega® Survey refers to the Answer Layout field on the Complex Question form, but this field is no longer supported. For more information about the question layout formats that Pega Survey supports, see Pega Survey.