Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Data synchronization does not resume after mobile app restart

Valid from Pega Version 8.3

If an offline-enabled mobile app that you build with Pega Infinity Mobile Client is stopped during an initial data synchronization session, the data synchronization does not resume when the mobile app is restarted. Users must not stop the mobile app before initial data synchronization finishes.

For more information about data synchronization, see Offline capability and Guidelines for creating an offline-enabled application.

Integration

Valid from Pega Version 7.1.4

Critical customer-driven product improvements were made to SOAP services, SOAP connectors and connector wizard, CMIS connectors, and the Pega Image Viewer. These fixes addressed a handful of functionality gaps discovered in PRPC 7.1 and earlier releases by internal and external customers.

  • A Connect-CMIS instance which was created using a reference to an ATOM Server Instance may now use Global Resource Settings.
  • The Execute Synchronously (one-way operation) has been enhanced for SOAP Services.
  • The Silverlight version of PegaImageViewer has been enhanced to print ranges of multiple pages at once.
  • The SOAP Wizard has been improved to show all the ports which are available in the WSDL file.
  • Two way SSL has been enhanced for the Connect-REST rule.

 

User Interface

Valid from Pega Version 7.1.4

This release had a focus around improving support for accessibility for all the PRPC UI Components as well as extending capabilities for responsive design with grids and tabs. A series of cosmetic changes and fixes are included.

  • Improvements have been made for action items being opened in a dynamic container.
  • Row repeat functionality in sections has been improved to better handle source properties.
  • Screen layouts have been optimized for the iPhone platform
  • The display on dynamic containers has been enhanced to provide the same behavior for both single-mode and multi-mode.
  • The Launch Harness feature has been improved to launch into a pop-up window.
  • The operator menu will now display from the Case Manager portal.
  • The Primary Page functionality has been enhanced for control-defined Repeating Tab Headers.
  • Using local actions defined as modal windows has been enhanced to work in an iPAD using a Safari browser.
  • When using a modal dialog to open a flow action in a repeat grid, to add an item to the list, users may now cancel out of this dialog if no changes are needed.

Data Management

Valid from Pega Version 7.1.3

Improvements to data handling were made for the Data Pages, autopopulate properties, and reference properties.  Lightweight lists were optimized.

  • Property references are now maintained on the Work Page.
  • PageList properties can reference a Data Page.
  • Auto-populate properties can be used in a seciton to show results from a Data Page.
  • Data Pages can run in “Page” mode as well as “List” mode
  • The "Rules Not Using Lightweight List" report was enhanced.
  • A PageList property that references a Data Page may be used to populate a grid.
  • Related autopopulated properties can now be referenced.

Integration

Valid from Pega Version 7.1.3

Usability enhancements have been made to the integration wizards. The REST end-point integration has been improved, and XML parsing functionality has been enhanced.

  • PRPC services can return Report or Listview data as XML.
  • Work items may now be processed when accessing from a link in system-created emails.
  • An SMTP outage will not cause an application to stop working.
  • File listener will now read files using a leading asterisk (*).
  • XML Parse rule will handle schema validation.
  • PegaImageViewer will now work with Version 7.1.
  • Security measures are enhanced for SOAP connections to web services.
  • After generating rules using REST wizard, the Undo Generation button will delete all the generated rules.
  • Email wizard has been improved.

User Interface

Valid from Pega Version 7.1.3

Issues for cross-browser support for Designer Studio have been addressed. Improvements were made in run-time performance for data pages with grids, and a number of cosmetic changes and fixes were made.

  • Improved loading of Javascript files during saving Harness rules.
  • Login Performance improvements
  • A cursor pointer issue was addressed in Case Manager.
  • In reports, data in columns will now right-align.
  • Improved section validation functionality
  • Harnesses with screen layouts will now save when there is a refresh condition on a panel.
  • Outline View tree has been improved.
  • Improvements to Repeat Grids using Data Pages as a source.
  • Formatted text cells can be put into a grid to display the value of a property retrieved from a Report Definition join.
  • Designer Studio changes to support IE9 and IE10.
  • Improved designer studio layout
  • Designer Studio changes to support quirks mode in IE8 and IE9.
  • Improvements to SmartLabels in Data Pages
  • Tab groups will take parameters for pre-activities in a defer load setup.
  • Sections support nested dynamic layouts.

JavaMail API upgrade has potential SMTP configuration error

Valid from Pega Version 7.1.8

The JavaMail API has been upgraded from 1.4.1 to 1.5.2 in this release. This improvement provides greater compatibility and secure connectivity with leading industry email servers.

During the upgrade process, there is a known issue for some configurations of email servers, including Microsoft Exchange Server, that requires the use of an additional setting. After upgrading to this release, if you experience authentication failures when attempting to send email or test SMTP connectivity, do one of the following:

  • Recommended: Review the Microsoft Exchange email server settings to ensure proper configuration for SMTP authentication. In some cases, the use of port 587 instead of the traditional default SMTP port 25 has been shown to address this issue.
  • Create the following Dynamic System Setting with the value "true," and then restart email listeners:

Owning Ruleset: Pega-IntegrationEngine

Setting Purpose: javamail/NoAuthMechanismsRetry

After any email server configuration or upgrade, it is recommended that email listeners are re-tested without using this Dynamic System Setting.

See About Email Account data instances for information on configuring email account records.

Number and text input controls on Android devices may not display the correct keyboard

Valid from Pega Version 7.1.8

When running a Pega 7 application on a device using the Android operating system, pxNumber and pxTextInput controls may not display when using the desired on-screen keyboard. This happens when the number or text input type is set to number.

At design time, the input type is selected in the Editable Format section of the Presentation tab in the Cell Properties panel for a pxNumber or pxTextInput control. Due to a known limitation in some versions of the Android OS running on some devices, the keyboard displayed at run time may not support entry of decimal values when a Number type keyboard is specified.

To resolve this issue, use the Phone type when numbers with decimal values may be required. Using the Phone type displays a numerical phone keyboard. The Android phone keyboard includes both commas and periods so that decimals may be entered.

Cell Properties dialog

The Phone type selected in the Presentation tab of a Number control

Note that this issue only occurs on Android devices. It is recommended that applications for iOS continue to use type=“Number”.

The Create Build button appears grayed out when configuring and building a mobile application

Valid from Pega Version 7.1.8

When you attempt to configure and build your Android or iOS mobile application from the Mobile tab, the Create build button might appear dimmed. This issue occurs if any of the access roles in the access group were cloned from the PegaRULES:SysAdm4 access role.

Refer to Troubleshooting Pega Mobile Client to learn how to fix this issue in your application.

Offline configuration limitation

Valid from Pega Version 7.1.8

When enabling the offline capability for a case type, do not select the Enable offline check box in Case Designer because it incorrectly sets the locking strategy. Instead, select the Enable offline mode check box on the Advanced tab of the Case Type form.

To open the Case Type form from Case Designer, click Open on the Actions menu.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us