Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Cannot copy final section rules in UI Kit ruleset

Valid from Pega Version 7.1.6

You cannot copy section rules in the UI Kit ruleset (UI-Kit-71) that start with pz or px (final rules in the base PRPC rulesets).

Instead, to customize these rules, use the Copy/Merge Ruleset tool, available at Designer Studio >System > Tools > Refactor Rulesets, to copy all rules from the UI Kit into your application ruleset. You can then check the section rules in and out.

Microsof Internet Explorer 9 (IE9) may display a script error when clicking a Help button

Valid from Pega Version 7.1.6

A script error may be displayed when clicking a Help button when script error notification is turned on in the browser. As a work around, uncheck the Display a notification about every script error option in the Advanced tab of the Options dialog box in Microsoft Internet Explorer 9.

JavaMail API upgrade has potential SMTP configuration error

Valid from Pega Version 7.1.8

The JavaMail API has been upgraded from 1.4.1 to 1.5.2 in this release. This improvement provides greater compatibility and secure connectivity with leading industry email servers.

During the upgrade process, there is a known issue for some configurations of email servers, including Microsoft Exchange Server, that requires the use of an additional setting. After upgrading to this release, if you experience authentication failures when attempting to send email or test SMTP connectivity, do one of the following:

  • Recommended: Review the Microsoft Exchange email server settings to ensure proper configuration for SMTP authentication. In some cases, the use of port 587 instead of the traditional default SMTP port 25 has been shown to address this issue.
  • Create the following Dynamic System Setting with the value "true," and then restart email listeners:

Owning Ruleset: Pega-IntegrationEngine

Setting Purpose: javamail/NoAuthMechanismsRetry

After any email server configuration or upgrade, it is recommended that email listeners are re-tested without using this Dynamic System Setting.

See About Email Account data instances for information on configuring email account records.

Number and text input controls on Android devices may not display the correct keyboard

Valid from Pega Version 7.1.8

When running a Pega 7 application on a device using the Android operating system, pxNumber and pxTextInput controls may not display when using the desired on-screen keyboard. This happens when the number or text input type is set to number.

At design time, the input type is selected in the Editable Format section of the Presentation tab in the Cell Properties panel for a pxNumber or pxTextInput control. Due to a known limitation in some versions of the Android OS running on some devices, the keyboard displayed at run time may not support entry of decimal values when a Number type keyboard is specified.

To resolve this issue, use the Phone type when numbers with decimal values may be required. Using the Phone type displays a numerical phone keyboard. The Android phone keyboard includes both commas and periods so that decimals may be entered.

Cell Properties dialog

The Phone type selected in the Presentation tab of a Number control

Note that this issue only occurs on Android devices. It is recommended that applications for iOS continue to use type=“Number”.

The Create Build button appears grayed out when configuring and building a mobile application

Valid from Pega Version 7.1.8

When you attempt to configure and build your Android or iOS mobile application from the Mobile tab, the Create build button might appear dimmed. This issue occurs if any of the access roles in the access group were cloned from the PegaRULES:SysAdm4 access role.

Refer to Troubleshooting Pega Mobile Client to learn how to fix this issue in your application.

Offline configuration limitation

Valid from Pega Version 7.1.8

When enabling the offline capability for a case type, do not select the Enable offline check box in Case Designer because it incorrectly sets the locking strategy. Instead, select the Enable offline mode check box on the Advanced tab of the Case Type form.

To open the Case Type form from Case Designer, click Open on the Actions menu.

Creating data page unit tests in Internet Explorer 8

Valid from Pega Version 7.1.8

When creating data page unit tests, selecting a parent property does not automatically select the child properties when using Internet Explorer 8.

Page and page list properties to be included in a data page unit test are selected on the Create test screen by selecting a check box next to the property name. Normally, selecting the check box of a parent property automatically selects all subsequent child properties as well. When using Internet Explorer 8, child properties are not automatically selected when the parent property's check box is selected.

The solution requires selecting all of the desired child properties individually. Select the check box next to each child property to include it in the data page unit test.

Precision of Oracle Timestamp property when using RDB-Save

Valid from Pega Version 7.1.8

DateTime properties that are mapped to an Oracle Timestamp column will experience a loss of precision when they are saved using the RDB-Save method. When you use RDB-Save for an Oracle Timestamp, precision will be accurate to the second. For example, a value of 20171119T124745.006 will be saved as 20171119T124745. When you use Obj-Save, precision will be accurate to the millisecond. For more information, see DateTime property mapping in Oracle for Pega 7.

Tags disappear from Rich Text Editor source mode

Valid from Pega Version 8.5

When you use Rich Text Editor in HTML source mode, some tags disappear from the markup, which causes backward compatibility issues and data loss.

Cause

Pega Platform™ version 8.5.5 introduced the DOM Purifier security plugin. The plugin removes potentially vulnerable tags, including custom tags, from the raw HTML code in the Rich Text Editor source mode.

Workaround

You can disable the DOM Purifier plugin by adding the the window.disableDomPurifier = true markup to the userWorkForm HTML fragment rule.

Alternatively, as of Pega Platform version 8.5.6, you can add a tag to the allow list by including the window.rteCustomAllowedTags = ['myCustomTag'] snippet in the userWorkForm HTML fragment rule. 

In Pega Platform versions 8.5.6 to 8.6, the iframe tag is added to the allow list by default.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us