Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Gadget configuration by using IAC gateway console is no longer supported

Valid from Pega Version 7.2.1

The Internet Application Composer (IAC) gateway was deprecated in Pega Platform™ 7.2.1 and is no longer supported. The IAC was used to embed a Pega Platform application, such as a gadget, on the pages of a web application that was located on your intranet, extranet, or internet site.

Upgrade impact

After an upgrade to Pega Platform 8.5, the configuration of gadgets through the IAC gateway console is no longer supported.

What steps are required to update the application to be compatible with this change?

To make subsequent changes to your current web mashup, use Pega Web Mashup. 

For more information, see Tutorial: Creating a mashup with Pega Web Mashup.

Screenshot generation runs on local client

Valid from Pega Version 7.1.8

If you generate screenshots to include in your application document, this process still runs on your local client. Additionally, you are still required to use Internet Explorer to use this feature.

Warning message when opening server-generated documents

Valid from Pega Version 7.1.8

Depending on your system configuration, the following warning message might be displayed when you open a document that was generated on the server.

If you click No, certain content (for example, Table of Contents) is not populated in the document. Instead, click Yes and save the document.

Warning message dialog

The warning message that displays

Derby databases are no longer supported

Valid from Pega Version 7.1.8

Previously, an embedded Derby database could be used as a file system. This setup was configured by setting storage/class/<<filesystem>>/type to "embedded" in the prconfig file.

After upgrading, storage types that are specified as "embedded" now default to the local file system.

JavaMail API upgrade has potential SMTP configuration error

Valid from Pega Version 7.1.8

The JavaMail API has been upgraded from 1.4.1 to 1.5.2 in this release. This improvement provides greater compatibility and secure connectivity with leading industry email servers.

During the upgrade process, there is a known issue for some configurations of email servers, including Microsoft Exchange Server, that requires the use of an additional setting. After upgrading to this release, if you experience authentication failures when attempting to send email or test SMTP connectivity, do one of the following:

  • Recommended: Review the Microsoft Exchange email server settings to ensure proper configuration for SMTP authentication. In some cases, the use of port 587 instead of the traditional default SMTP port 25 has been shown to address this issue.
  • Create the following Dynamic System Setting with the value "true," and then restart email listeners:

Owning Ruleset: Pega-IntegrationEngine

Setting Purpose: javamail/NoAuthMechanismsRetry

After any email server configuration or upgrade, it is recommended that email listeners are re-tested without using this Dynamic System Setting.

See About Email Account data instances for information on configuring email account records.

Number and text input controls on Android devices may not display the correct keyboard

Valid from Pega Version 7.1.8

When running a Pega 7 application on a device using the Android operating system, pxNumber and pxTextInput controls may not display when using the desired on-screen keyboard. This happens when the number or text input type is set to number.

At design time, the input type is selected in the Editable Format section of the Presentation tab in the Cell Properties panel for a pxNumber or pxTextInput control. Due to a known limitation in some versions of the Android OS running on some devices, the keyboard displayed at run time may not support entry of decimal values when a Number type keyboard is specified.

To resolve this issue, use the Phone type when numbers with decimal values may be required. Using the Phone type displays a numerical phone keyboard. The Android phone keyboard includes both commas and periods so that decimals may be entered.

Cell Properties dialog

The Phone type selected in the Presentation tab of a Number control

Note that this issue only occurs on Android devices. It is recommended that applications for iOS continue to use type=“Number”.

Creating data page unit tests in Internet Explorer 8

Valid from Pega Version 7.1.8

When creating data page unit tests, selecting a parent property does not automatically select the child properties when using Internet Explorer 8.

Page and page list properties to be included in a data page unit test are selected on the Create test screen by selecting a check box next to the property name. Normally, selecting the check box of a parent property automatically selects all subsequent child properties as well. When using Internet Explorer 8, child properties are not automatically selected when the parent property's check box is selected.

The solution requires selecting all of the desired child properties individually. Select the check box next to each child property to include it in the data page unit test.

Configuration required for data operations on external schema when using a Postgres database

Valid from Pega Version 7.1.8

When you use the API for data operations on external schema in the Postgres database, you must update the prconfig.xml file. No other platform requires a prconfig.xml update.

To update the prconfig.xml file:

  1. Stop the server and add the following entry to the prconfig.xml file:
    env name="database/databases/postgres_ext/defaultSchema"
    value="externalschema"
    where postgres_ext is the external database that uses the external schema “externalschema”.
  2. Restart the server.

Ignore locale settings requires refresh after server restarts

Valid from Pega Version 7.2.1

The Ignore locale check box in operator preferences is selected to display Designer Studio in U.S. English. After a server restarts, screens initially ignore this setting. When the screen is refreshed or reopened, the screen is rendered as expected.

Flexbox-based dynamic layouts not supported for Android 4.4 and earlier

Valid from Pega Version 7.2.1

Flexbox-based dynamic layouts are not supported in Android 4.4 and earlier. When developing applications to be used on devices running Android 4.4 and earlier, use the inline-block layout mode for dynamic layouts.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us