Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Improved case auditing in App Studio

Valid from Pega Version 8.5

In Cosmos UI, App Studio now supports expandable case steps. This enhancement helps users quickly navigate a case and provides deeper insight into the case flow. In addition, Cosmos UI also introduces an improved history view that helps you better meet your business auditing requirements.

For more information, see Managing Cosmos UI settings in case designer.

Upgrade impact

After an upgrade to Pega Platform 8.5 or later, the history and chevron designs change automatically. However, applications with custom history settings might still display the styling that you defined in the override.

What steps are required to update the application to be compatible with this change?

If your application uses custom settings and you want to use the updated history, remove the overrides from the pyWorkCommonActions rule.

Failed Robotic Assignments work queue type changed to Standard

Valid from Pega Version 8.5

The default Failed Robotic Assignments work queue type is now Standard. In previous releases, the default type was Robotic. For usage information, see Configuring a work queue for robotic automation.

Upgrade impact

After upgrading to Pega Platform 8.5 and later, you cannot save case types in which you configure the Queue for robot smart shape to route new assignments to the Failed Robotic Assignments work queue. Existing assignments that you routed to the Failed Robotic Assignments work queue are not affected.

How do I update my application to be compatible with this change?

As a best practice, do not use the Failed Robotic Assignments work queue in your custom implementations. Instead, configure the Queue for robot smart shape to route new assignments to a Robotic work queue. When possible, update existing case types to use the robotic work queues that you created in your application.

Tamper-proof Pega Web Mashup loading

Valid from Pega Version 8.5

To protect your application from hackers, Pega Web Mashup is now loaded in a more secure way. The system generates a channel ID in the mashup code for validation on the server, before passing the mashup request. 

For more information, see Creating a mashup.

Upgrade impact

After an upgrade to Pega Platform 8.5, existing mashups, which do not have the channel ID parameter in their code, cannot load and users see the access control warning.

What steps are required to update the application to be compatible with this change?

If you need to maintain full availability of the mashup during the upgrade of the production environment, perform the steps in Migrating existing mashups.

Derby databases are no longer supported

Valid from Pega Version 7.1.8

Previously, an embedded Derby database could be used as a file system. This setup was configured by setting storage/class/<<filesystem>>/type to "embedded" in the prconfig file.

After upgrading, storage types that are specified as "embedded" now default to the local file system.

JavaMail API upgrade has potential SMTP configuration error

Valid from Pega Version 7.1.8

The JavaMail API has been upgraded from 1.4.1 to 1.5.2 in this release. This improvement provides greater compatibility and secure connectivity with leading industry email servers.

During the upgrade process, there is a known issue for some configurations of email servers, including Microsoft Exchange Server, that requires the use of an additional setting. After upgrading to this release, if you experience authentication failures when attempting to send email or test SMTP connectivity, do one of the following:

  • Recommended: Review the Microsoft Exchange email server settings to ensure proper configuration for SMTP authentication. In some cases, the use of port 587 instead of the traditional default SMTP port 25 has been shown to address this issue.
  • Create the following Dynamic System Setting with the value "true," and then restart email listeners:

Owning Ruleset: Pega-IntegrationEngine

Setting Purpose: javamail/NoAuthMechanismsRetry

After any email server configuration or upgrade, it is recommended that email listeners are re-tested without using this Dynamic System Setting.

See About Email Account data instances for information on configuring email account records.

Number and text input controls on Android devices may not display the correct keyboard

Valid from Pega Version 7.1.8

When running a Pega 7 application on a device using the Android operating system, pxNumber and pxTextInput controls may not display when using the desired on-screen keyboard. This happens when the number or text input type is set to number.

At design time, the input type is selected in the Editable Format section of the Presentation tab in the Cell Properties panel for a pxNumber or pxTextInput control. Due to a known limitation in some versions of the Android OS running on some devices, the keyboard displayed at run time may not support entry of decimal values when a Number type keyboard is specified.

To resolve this issue, use the Phone type when numbers with decimal values may be required. Using the Phone type displays a numerical phone keyboard. The Android phone keyboard includes both commas and periods so that decimals may be entered.

Cell Properties dialog

The Phone type selected in the Presentation tab of a Number control

Note that this issue only occurs on Android devices. It is recommended that applications for iOS continue to use type=“Number”.

Creating data page unit tests in Internet Explorer 8

Valid from Pega Version 7.1.8

When creating data page unit tests, selecting a parent property does not automatically select the child properties when using Internet Explorer 8.

Page and page list properties to be included in a data page unit test are selected on the Create test screen by selecting a check box next to the property name. Normally, selecting the check box of a parent property automatically selects all subsequent child properties as well. When using Internet Explorer 8, child properties are not automatically selected when the parent property's check box is selected.

The solution requires selecting all of the desired child properties individually. Select the check box next to each child property to include it in the data page unit test.

Configuration required for data operations on external schema when using a Postgres database

Valid from Pega Version 7.1.8

When you use the API for data operations on external schema in the Postgres database, you must update the prconfig.xml file. No other platform requires a prconfig.xml update.

To update the prconfig.xml file:

  1. Stop the server and add the following entry to the prconfig.xml file:
    env name="database/databases/postgres_ext/defaultSchema"
    value="externalschema"
    where postgres_ext is the external database that uses the external schema “externalschema”.
  2. Restart the server.

Precision of Oracle Timestamp property when using RDB-Save

Valid from Pega Version 7.1.8

DateTime properties that are mapped to an Oracle Timestamp column will experience a loss of precision when they are saved using the RDB-Save method. When you use RDB-Save for an Oracle Timestamp, precision will be accurate to the second. For example, a value of 20171119T124745.006 will be saved as 20171119T124745. When you use Obj-Save, precision will be accurate to the millisecond. For more information, see DateTime property mapping in Oracle for Pega 7.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us